• 제목/요약/키워드: Electromagnetic Field (EMF)

검색결과 102건 처리시간 0.026초

전자기력을 이용한 박판 성형 공정 해석 및 성형성 평가 (Thin Sheet Metal Forming Process Analysis and Formability Evaluation using Electromagnetic Force)

  • 서영호;허성찬;구태완;송우진;김정;강범수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2008
  • Electromagnetic forming (EMF) technology, which is one of the high speed forming methods, has been used for the forming process in various industry fields. Numerical approach by finite element simulation of the EMF process is presented in this study. The implicit code is used to obtain the numerical model of the time-varying currents that are discharged through the coil in order to obtain the transient magnetic forces. In addition, the body forces generated in the workpiece are used as the loading condition to analyze deformation of thin sheet metal workpiece using explicit code. Numerical approach for a dimpled shape by EMF process is carried out and the simulated results of the dimpled shape by EMF are reviewed in view of the deformed shape and formability evaluation.

  • PDF

The Effect of Sub-chronic Whole-Body Exposure to a 1,950 MHz Electromagnetic Field on the Hippocampus in the Mouse Brain

  • Son, Yeonghoon;Jeong, Ye Ji;Kwon, Jong Hwa;Choi, Hyung-Do;Pack, Jeong-Ki;Kim, Nam;Lee, Yun-Sil;Lee, Hae-June
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.151-157
    • /
    • 2015
  • The increasing use of mobile phones has raised public concern about the possible biological effects of radiofrequency electromagnetic field (RF-EMF) exposure on the human brain. To investigate the potential effect of RF-EMF exposure on the brain, we examined the behaviors and hippocampal morphology of C57BL/6 mice after sub-chronic exposure to RF-EMFs with a relatively high SAR level (5.0 W/kg). We applied a 2-hour daily exposure of WCDMA 1,950 MHz using a reverberation chamber that was designed for whole-body exposure for 60 days. In the behavioral tests, RF-EMF did not alter the physical activity or long-term memory of mice. Moreover, no alteration was found in the neuronal and glial cells in the hippocampus by RF-EMFs. In this study, we showed that sub-chronic whole body RF exposure did not produce memory impairment and hippocampal morphological alteration in C57BL/6 mice.

Investigation of Electromagnetic Field Coupling with Twisted Conducting Line by Expanded Chain Matrix

  • Cho, Yong-Sun;Ro, Jong-Suk;Chung, Yong-Seek;Cheon, Changyul;Jung, Hyun-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.364-370
    • /
    • 2013
  • In the current paper, we propose a new modeling algorithm to analyze the coupling between an incident electromagnetic field (EMF) and a twisted conducting line, which is a kind of non-uniform line. Typically, analysis of external field coupling to a uniform transmission line (TL) is implemented by the Baum-Liu-Tesche (BLT) equation so that the induced load responses can be obtained. However, it is difficult to apply this method to the analysis of a twisted conducting line. To overcome this limitation, we used a chain matrix composed of ABCD parameters. The proposed algorithm expands the dimension of the previous chain matrix to consider the EMF coupling effectiveness of each twisted pair, which is then applied to multi-conductor transmission line (MTL) theory. In addition, we included a comparative study that involves the results of each method applied in the conventional BLT equation and new proposed algorithm in the uniform two-wire TL case to verify the proposed method.

전자기유량계의 설계 및 제작 (Design and Fabrication of an Electromagnetic Flowmeter)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

이동전화 주파수에 대한 전자파 잔향실 형태의 전신 노출장치 개발 및 유효성 평가 (Development and Validation of Reverberation Chamber Type Whole Body Exposure System fer Mobile Phone Frequency)

  • 정기범;고경배;도현정;백정기;정연춘;최재훈
    • 한국전자파학회논문지
    • /
    • 제15권3호
    • /
    • pp.291-300
    • /
    • 2004
  • 이동통신 서비스의 급격한 증가로 인해, EMF(Electromagnetic field)노출의 생물학적 효과에 대한 많은 연구들이 수행되어져 왔다. 그러나 연구 수행에 있어서 필요한 무선 주파수 대역에서의 균일장 생성은 쉬운 일이 아니다. 이러한 어려움을 극복하기 위해 전신노출 시 스템에서의 전기장과 SAR(Specific Absorption Rate) 분포 측정이 발전을 해왔다. 본 논문에서는 EMC 대용 챔버로의 활용 가능성이 높은 전자파 잔향실 챔버를 이용하여 동물 실험용 전신 노출 장치를 개발하였다. 설계된 전자파 잔향실은 시뮬레이션과 측정 데이터를 이용하여 시험영역의 균일장에 대한 유효성을 검증하였다. 마우스에 대한 전신노출 실험에 있어서, 노출된 전자파에 대해 SAR을 확인하기 위해서 FDTD수치해석 방법과 측정 결과를 비교하였다. 전자파 잔향실 내부에서의 전기장 분포 특성을 해석하고, 이러한 해석 결과들을 통계적으로 처리하였다. CDMA 이동전화 주파수 대역에서(PCS & Cellular 대역) 입력 파워 변화에 따른 실험상태에서의 마우스 전신 SAR 평균값 및 국부 최대값을 제시하였다.

공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석 (Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline)

  • 신한수;송혜진;변진규
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

전자기유량계의 개발및 신호 특성에 관한 연구 (A study on the development of an electromagnetic flowmeter and the characterization of flow signal)

  • 임기원;김창호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.361-364
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The measuring tube of the EMF was basically designed as 100 m diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. To obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF For the characterization of EU, the uncertainty of calibrator was estimated within ${\pm}0.5{\%}$, the method of estimation was in accordance with the ISO 17025 recommendation. It was found that the flow signals between the electrodes were about ${\pm}60\;-\;{\pm}300{\mu}V$, which were sufficient for the discrimination of the flowmeter and protecting the noise. The test result against the calibrator, showed the good linearity in the range of $3 m^{3}/h\;and\;70m^{3}/h$. A commercialized design of the EMF will be technically more competitive in domestic and foreign market.

  • PDF

Effects of 835-MHz Radiofrequency Radiation on the Chromosomal DNA of Mouse Thymic Lymphoma L5178Y $Tk^{+/-}$ Cells

  • Choi, Jong-Soon;Son, TaeHo;Chang, Sung-Keun;Hong, Sae-Yong
    • 환경생물
    • /
    • 제22권4호
    • /
    • pp.507-512
    • /
    • 2004
  • This study was focused on the risk assessment of whether radiofrequency electromagnetic fields generated by mobile phone is cytogenetically toxic or not. We conducted the effects of 835-MHz electromagnetic field (EMF) on DNA strand breaks in mouse thymic lymphoma L5178Y $Tk^{+/1-}$ cells using alkaline comet assay. EMF frequency 835-MHz we chosen is one of the most popular communication frequency bands in Korean code-division multiple-access (CDMA) mobile phone system. The cells were exposed to 835-MHz EMF alone or 835-MHz EMF combined with cyclophosamide(CPA) or 4-nitroquinoline-1-oxide (4NQO) at specific absorption rate (SAR) of 4.0 W $kg^{-l}$ for 24 and 48hrs. DNA damage expressed as tail moment was increased more than two-fold after exposure to 835-MHz EMF for 24 and 48hr. In particular, CPA for 48hr and 4NQO for 24 hr enhanced notably the tail moment to 9-fold and 16-fold in the presence of 835-MHz EMF, respectively, compared to each single treatment. From these results, it appears that exposure to CDMA-mobile phone radiation at 835-MHz frequency may potentiate DNA strand breaks of mouse thymic lymphoma L5178Y $Tk^{+/1-}$;cells under the defined conditions of this study.

A Study on the Convenient EMF Compliance Assessment for Base Station Installations at a Millimeter Wave Frequency

  • Lee, Young Seung;Lee, Haeng-Seon;Choi, Hyung-Do
    • Journal of electromagnetic engineering and science
    • /
    • 제18권4호
    • /
    • pp.242-247
    • /
    • 2018
  • This paper studies a convenient electromagnetic field (EMF) compliance assessment for base station installations at a millimeter wave (mmW) frequency. We utilize ray-tracing analysis as a numerical method for examining the wave propagation characteristic. Various installation cases are considered and the important parameters with a significant effect on the maximum power density levels are produced. We finally suggest the several scenarios for the convenient assessment of mmW base stations, which allow us to conduct cost effective computational tests compared with the current assessment procedure in the guideline.