• Title/Summary/Keyword: Electromagnetic Field (EMF)

Search Result 102, Processing Time 0.028 seconds

A Study on Electromagnetic Field Emission and Its Effect on Electromagnetic Environment (전자파 환경의 전자기장 방출과 그 영향에 대한 고찰)

  • Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.613-618
    • /
    • 2019
  • EMF (Electromagnetic Field) is a valuable resource for living in a knowledge-based information society. The EMF is used in home appliances that make our lives easy and convenient, and in telecommunication devices such as mobile phones, personal computers, medical devices and broadcasting towers. However, the biological hazards associated with EMF exposure are also increasing in signal from telecommunication devices. Studies of the effects of EMF exposure on humans have been conducted for a long time, but it has not yet been demonstrated whether the EMF effect is harmful. In this paper, we examine the electromagnetic field emitted from various electronic devices around living and its effect.

Dual effect of Low- frequency Electromagnetic Field on Muscle Histopathology of Caspian Sea Cyprinus carpio

  • Samiee, Farzaneh;Samiee, Keivandokht
    • Journal of fish pathology
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2017
  • The effect of electromagnetic field on aquatic organisms has received little attention. In the current study, the effect of 50Hz electromagnetic field on muscle histopathology of Caspian Sea Cyprinus carpio, a species of economic importance, was investigated. A total of 120 healthy fish were used in this study. They were classified randomly in one of two groups as follows: Control or unexposed EMF group and experimental group with 5 different magnetic field intensities (0.1, 1, 3, 5 and 7mT) at 2 different exposure times including 30 and 60 minutes. Fish in the experimental group were exposed only once. Two weeks after exposure, dorsal muscles sectioned transversely, stained and were examined using a light microscope. Histopathologic assessments showed significant difference between control and EMF exposed groups at both 30 min. (p<0.01) and 60 min. (p<0.001) exposure times. We report for the first time that electromagnetic field in interaction with muscular tissue of Cyprinus carpio exhibits a dual effect which depends on the field intensity, and exposure time. At short exposure time (30 min.), EMF stimulates muscle growth process. At longer exposure time (60 min.), EMF can damage muscle tissue and result in muscle necrosis. More research is required to elucidate precise mechanisms involved in muscle hypertrophy and pathologic changes.

Properties of Extremely Low Frequency Electromagnetic Fields and their Effects on Mouse Testicular Germ Cells

  • Kim, Yeon-Sook;Lee, Suk-Keun
    • International Journal of Oral Biology
    • /
    • v.35 no.4
    • /
    • pp.137-144
    • /
    • 2010
  • To evaluate the biohazard properties of an extremely low frequency electromagnetic field (ELF-EMF), we explored the physical properties of the ELF-EMF that generates the electric current induction in the secondary coil from the chamber of a primary solenoid coil. We subsequently explored the biological effects of a strong alternating electromagnetic field (EMF), ranging from 730-960 Gauss, on the mouse testis. Mice were exposed to an alternating EMF field induced by a rectangular electric current at 1, 7, 20, 40, and 80 Hertz, for 1, 3, 5, and 7 hours. The mouse testes were examined for proliferative activity and apoptosis using the in situ terminal deoxynucleotidyl transferase (TdT) method and by immunostaining of proliferating cell nuclear antigen (PCNA), respectively. We found that the electric currentm induction increased in the 6-8 Hertz range, and that exposure to an ELF-EMF induced the apoptosis of mouse spermatocytes. In situ TdT staining was found to be most prominent in 7 Hertz group, and gradually reduced in the 20, 40, and 80 Hertz groups. These data suggest that a strong EMF can induce reproductive cell death within a short time, and the harmful effects of the EMF are maximal at low frequency alternating EMFs.

Effect of electromagnetic field exposure on the reproductive system

  • Gye, Myung-Chan;Park, Chan-Jin
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • The safety of human exposure to an ever-increasing number and diversity of electromagnetic field (EMF) sources both at work and at home has become a public health issue. To date, many in vivo and in vitro studies have revealed that EMF exposure can alter cellular homeostasis, endocrine function, reproductive function, and fetal development in animal systems. Reproductive parameters reported to be altered by EMF exposure include male germ cell death, the estrous cycle, reproductive endocrine hormones, reproductive organ weights, sperm motility, early embryonic development, and pregnancy success. At the cellular level, an increase in free radicals and $[Ca^{2+}]i$ may mediate the effect of EMFs and lead to cell growth inhibition, protein misfolding, and DNA breaks. The effect of EMF exposure on reproductive function differs according to frequency and wave, strength (energy), and duration of exposure. In the present review, the effects of EMFs on reproductive function are summarized according to the types of EMF, wave type, strength, and duration of exposure at cellular and organism levels.

Numerical Simulation of Thin Sheet Metal Forming Process using Electromagnetic Force (전자기력을 이용한 박판 성형공정의 해석적 연구)

  • Seo, Y.H.;Heo, S.C.;Ku, T.W.;Song, W.J.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.17 no.1
    • /
    • pp.35-45
    • /
    • 2008
  • Electromagnetic Forming (EMF) technology such as magnetic pulse forming, which is one of the high velocity forming methods, has been used for the joining and forming process in various industry fields. This method could be derived a series of deformation of sheet metal by using a strong magnetic field. In this study, numerical approach by finite element simulation of the electromagnetic forming process was presented. A transient electromagnetic finite element code was used to obtain the numerical model of the time-varying currents that are discharged through the coil in order to obtain the transient magnetic forces. Also, the body forces generated in electromagnetic field were used as the loading condition to analyze deformation of thin sheet metal workpiece using explicit dynamic finite element code. In this study, after finite element analysis for thin sheet metal forming process with free surface configuration was performed, analytical approach for a dimpled shape by using EMF was carried out. Furthermore, the simulated results of the dimpled shape by EMF were compared with that by a conventional solid tool in view of the deformed shape. From the results of finite element analysis, it is confirmed that the EMF process could be applied to thin sheet metal forming.

Safety of Electromagnetic Field Made by Intelligent Thermo-Acupuncture System (지능형온침자극기의 전자기장 측면의 안전성)

  • Yuk, Geun-Yeong;Lee, Seung-Ho;Kim, Young-Kon;Lim, Sa-Bi-Na
    • Korean Journal of Acupuncture
    • /
    • v.24 no.4
    • /
    • pp.69-84
    • /
    • 2007
  • Objectives : Intelligent thermo-acupuncture system (ITA-system) is invented for the convenient operation of thermo-acupuncture therapy. The aim of this study is to investigate the safety of 100 ㎑ electromagnetic field (EMF) made by ITA-system. Methods : We analysed the influence of this EMF on animals. In order to do experiment in the influence of EMF, male ICR mice were exposed to EMF at different distances from the ITA-system. And we examined weight, diet, behavior, organ and hematological changes. Results & Conclusions : According to the animal studies with mice about EMF influence, there was no significant difference between the control group and the exposed groups about them. In conclusion, the safety of 100 ㎑ EMF made from ITA-system through this animal research was checked.

  • PDF

Possible Effects of Radiofrequency Electromagnetic Field Exposure on Central Nerve System

  • Kim, Ju Hwan;Lee, Jin-Koo;Kim, Hyung-Gun;Kim, Kyu-Bong;Kim, Hak Rim
    • Biomolecules & Therapeutics
    • /
    • v.27 no.3
    • /
    • pp.265-275
    • /
    • 2019
  • Technological advances of mankind, through the development of electrical and communication technologies, have resulted in the exposure to artificial electromagnetic fields (EMF). Technological growth is expected to continue; as such, the amount of EMF exposure will continue to increase steadily. In particular, the use-time of smart phones, that have become a necessity for modern people, is steadily increasing. Social concerns and interest in the impact on the cranial nervous system are increased when considering the area where the mobile phone is used. However, before discussing possible effects of radiofrequency-electromagnetic field (RF-EMF) on the human body, several factors must be investigated about the influence of EMFs at the level of research using in vitro or animal models. Scientific studies on the mechanism of biological effects are also required. It has been found that RF-EMF can induce changes in central nervous system nerve cells, including neuronal cell apoptosis, changes in the function of the nerve myelin and ion channels; furthermore, RF-EMF act as a stress source in living creatures. The possible biological effects of RF-EMF exposure have not yet been proven, and there are insufficient data on biological hazards to provide a clear answer to possible health risks. Therefore, it is necessary to study the biological response to RF-EMF in consideration of the comprehensive exposure with regard to the use of various devices by individuals. In this review, we summarize the possible biological effects of RF-EMF exposure.

Biological Hazard of Electromagnetic Field Exposure: A Review (전자기파의 생체 위해성에 관한 소고)

  • Jung, Kyung-Ah;Gye, Myung-Chan
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.4
    • /
    • pp.241-250
    • /
    • 2011
  • The safety of human exposure to an ever-increasing number and diversity of electromagnetic field (EMF) sources both at work and at home has clearly become a public health issue. To date many $in$ $vivo$ and $in$ $vitro$ studies revealed that EMF exposure can alter cellular metabolism, endocrine function, immune activity, reproductive function, and fetal development in animal system. The major parameters found to be altered in cells or individuals following EMF exposure include an increase of free radicals, DNA damage, cancer risk, developmental defect, and reproductive dysfunctions. Epidemiological studies reported EMF can increase life-threatening illnesses such as leukemia, brain cancer, amyotrophic lateral sclerosis, clinical depression, suicide, and Alzheimer's disease has been identified. These effects of EMF exposure differ according to duration of exposure, frequency of waves, and strength (energy) of EMF. In the present review, we briefly introduced the physical properties of EMF and summarized the effect of EMF on human and wildlife animals according to types of EMF, duration of exposure at cellular and organism levels.

Health effects of electromagnetic fields on children

  • Moon, Jin-Hwa
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.11
    • /
    • pp.422-428
    • /
    • 2020
  • In today's world, most children are exposed to various manmade electromagnetic fields (EMFs). EMFs are electromagnetic waves less than 300 GHz. A developing child's brain is vulnerable to electromagnetic radiation; thus, their caregivers' concerns about the health effects of EMFs are increasing. EMF exposure is divided into 2 categories: extremely low frequencies (ELFs; 3-3,000 Hz), involving high-voltage transmission lines and in-house wiring; and radiofrequencies (RFs; 30 kHz to 300 GHz), involving mobile phones, smart devices, base stations, WiFi, and 5G technologies. The biological effects of EMFs on humans include stimulation, thermal, and nonthermal, the latter of which is the least known. Among the various health issues related to EMFs, the most important issue is human carcinogenicity. According to the International Agency for Research on Cancer's (IARC's) evaluation of carcinogenic risks to humans, ELFs and RFs were evaluated as possible human carcinogens (Group 2B). However, the World Health Organization's (WHO's) view of EMFs remains undetermined. This article reviews the current knowledge of EMF exposure on humans, specifically children. EMF exposure sources, biological effects, current WHO and IARC opinions on carcinogenicity, and effects of EMF exposures on children will be discussed. As well-controlled EMF experiments in children are nearly impossible, scientific knowledge should be interpreted objectively. Precautionary approaches are recommended for children until the potential health effects of EMF are confirmed.

The Level of Exposure to Electromagnetic Fields Strength from VDT According to the Arrangement of Working Space VDT (영상표시단말장치의 작업공간 배열에 따른 전자파 폭로 정도)

  • Han, Sangil;Lee, Sehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.146-154
    • /
    • 1998
  • This study was designed to investigate the workers' exposure level to electromagnetic field(EMF) in accordance with the VDT arrangement in the work place and distance from VDT. Author compared the exposure strength of EMF in line group(workers exposed to EMF from both front and back side) and in shielding group(workers exposed to EMF exclusively from front side). The levels of EMF at 30cm and 50cm from front side and at 30cm from back side of VDT were also measured. The result were as follows: 1. Mean distance between a monitor and a worker in shielding group ($47.7{\pm}8.7cm$) significantly longer than that in line group($44.3{\pm}7.2cm$). Strength of EMF in shielding group [$1.3{\pm}0.7V/m$ (electric field) and $18.2{\pm}11.5mA/m$ (magnetic field) were lower than in line group [$1.4{\pm}0.6V/m$ and $26.6{\pm}11.6mA/m$, respectively] at the workers' position. 2. The strength of EMF was decreased with the distance from VDT. The strength at 70cm from VDT was nearly the same as the background strength in the ordinary office rooms. 3. Working distance from 9 inch monitor was significantly shorter than that from 14 inch and wider sized monitors. 4. The strength of EMF in extremely low frequency spectrum of color monitors was higher then that of black and white monitor. 5. Metal coated filters significantly decreased the electric field strength of EMF when earth line was connected. Metallic shield was effectively decreased the EMF strength from VDT, but wooden shield was not. From the above results, line type arrangement of VDT in the work place using metallic shield at the back side of VDT, and metal coated filter to monitor with application of earth line were recommended. It is also recommended to maintain workers position to be 60cm or more distance from monitor and 140cm or more between VDTs for minimizing workers' exposure to EMF.

  • PDF