• Title/Summary/Keyword: Electromagnetic Field

Search Result 1,870, Processing Time 0.039 seconds

Characteristics of Time-Changing Electric and Magnetic Fields at a High Voltage Laboratory (고전압 실험실에서 시변성 전자계의 특성)

  • 이복희;이경옥;안창환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.83-93
    • /
    • 1997
  • This paper deals with measurements and evaluation of the time-changing electric and magnetic fields at a high-voltage laboratory. The electromagnetic disturbances originate mainly from ground faults and on/off operations of electric power equipments. The electronic circuits and control devices are very sensitive to electromagnetic interferences. It is necessory to evaluate the levels of interferences for a given electromagnetic environment. The electric field was observed by the electric field sensor having the bandwidth of the range from 40 Hz to 200 MHz, and the time-changing magnetic field was measured by the loop sensor of which the output is directly proportional to the incident signal. Also, the frequency components of the time-changing electric and magnetic fields induced by an oscillatory transient current and a chopped impulse voltage were analyzed by terms of the fast Fourier transformation, and those give the information about the levels of the electromagnetic interferences and the design of the electromagnetic shielding enclosures.

  • PDF

The Effects of Pulsed Electromagnetic Fields on Blood components, Antioxidant enzymes and Reactive Oxygen in Hyperlipidemic Rats (맥동전자장이 고지혈증 흰쥐의 혈액 성분, 항산화 효소 및 활성 산소에 미치는 영향)

  • Bang, Hyun-Soo;Jeong, In-Ho;Lee, Sang-Deok
    • Journal of Digital Convergence
    • /
    • v.12 no.7
    • /
    • pp.349-356
    • /
    • 2014
  • The present study was aimed to investigate the effects of the application of pulsed electromagnetic fields on the blood components associated hyperlipidemia, antioxidant enzymes and reactive oxygen. The subjects were divided into three groups: General Diet, High fat Diet, High fat diet and pulsed electromagnetic fields. Pulsed electromagnetic field was applied with pulsed electromagnetic energy therapy equipment. The Glucose, free fatty acids, triglycerides, cholesterol and insulin was used to measure hyperlipidemia-related blood components, and the GSH, GRD, XO and MDA was used to measure antioxidant enzymes and reactive oxygen. The applied pulsed electromagnetic field has improved the concentrations of blood components and increasing GSH and GRD, that were decreased due to a high-fat diet and by reducing the increased MDA and XO to a level of general diet group. Therefore, the applied pulsed electromagnetic field can be the effective treatment for changes in the blood composition of hyperlipidemic rats, enhancement of antioxidative activity and the inhibition of reactive oxygen.

A Numerical Analysis of Molten Steel Flow Under Applied Magnetic Fields in Continuous Casting

  • Yoon, Teuk-Myo;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2010-2018
    • /
    • 2003
  • Although continuous casting process has highly developed, there still remain many problems to be considered. Specifically, two vortex flows resulting from impingement against narrow walls make a flow field unstable in a mold, and it is directly related to internal and external defects of steel products. To cope with this instability, EMBR (Electromagnetic Brake Ruler) technique has been lately studied for the stability of molten steel flow, and it is revealed that molten steel flow in a mold can be controlled with applied magnetic field. However, it is still difficult to clarify flow pattern in an EMBR caster due to complex correlations among variables such as geometric factors, casting conditions, and the place and the intensity of charged magnetic field. In the present study, flow field in a mold is focused with different conditions of electromagnetic effect. To accurately analyze the case, three dimensional low Reynolds turbulent model and appropriate boundary conditions are chosen. To evaluate the electromagnetic effect in molten steel flow, dimensionless numbers are employed. The results show that the location and the intensity of the applied magnetic field significantly influence the flow pattern. Both impingement and internal flow pattern are changed remarkably with the change of the location of applied magnetic field. It turns out that an insufficient magnetic force yields adverse effect like channeling, and rather lowers the quality of steel product.

Survey on Magnetic Field around Substations and Proposals to Broaden Understanding of the Magnetic Field Characteristics (변전소 주변 자계 실태조사 및 자계 특성이 이해증진 방안)

  • Rhee, Seong-Su;Shin, Heon-Shik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.6
    • /
    • pp.526-534
    • /
    • 2009
  • The magnetic field of the extremely low frequency that occurs in the substation facilities was surveyed to present ways to broaden understanding of the magnetic field characteristics. We have investigated the level of the magnetic fields in the substation areas and control rooms of 25 substations in the metropolitan area in accordance with the measurement method of IEC CISPR(IEC/TC106 PT 62110). We propose objective and reliable policy approaches such as the electromagnetic field certification system to more accurately understand the property of magnetic field.

Analysis on Static Characteristics of Slotless Type Permanent Magnet Electrical Machines Using the Electromagnetic Transfer Relations (전자기 전달관계를 이용한 슬롯리스형 영구자석 전기기기의 정특성 해석)

  • Jang, Seok-Myeong;Choi, Jang-Young;Lee, Sung-Ho;Cho, Han-Wook
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.3
    • /
    • pp.138-145
    • /
    • 2006
  • It is well known that the accurate calculation of the field distribution is essential for the design of electrical machines. The analytical techniques for electromagnetic field can quickly and exactly determine airgap magnetic field distribution in electrical machines. Many analytical techniques have been investigated to predict the magnetic field distribution in PM machines equipped with permanent magnets. Using the analytical technique by transfer relations, D. L. Trumper and K. R. Davey already presented the design and analysis of linear permanent-magnet machines and induction machines, respectively. Using the transfer relations (Melcher's general methodology) to describe electromagnetic phenomena, this paper deals with the analysis on the magnetic field distribution due to PM and winding current, the induced voltage and the static torque characteristics in surface-mounted slotless type permanent magnet machine. The validity of the analysis results is confirmed by finite element (FE) analysis.

The Development of Electromagnetic Field Analysis Software for Virtual Training (가상 교육용 전자장 해석 프로그램 개발)

  • Wee, Sang Bong;Kim, Ki Beom
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.2 no.2
    • /
    • pp.55-60
    • /
    • 2010
  • We usually encounter Electro-magnetics phenomenons and only feel some part of that, but it is hard to feel it visually. Moreover understanding physically and quantitatively is not a easy work. These electrostatic field theory, magnetostatic field theory and interchange magnetic field theory combined with electromagnetic field are formulated experimentally and theoretically by James Clerk Maxwell in 1873. Electromagnetic field takes electro-magnetic phenomenons as a expansion of formula originated in Maxwell equations. Since this is based on expansion of formula, it is hard to understand for many students not only middle school and high school students learning it at the first time but also college students studying physics as a elementary class and even majors in electromagnetic field. The program is developed as a visual aid to cope with these problems, and even to deal with complex problem to estimate solution using numerical method.

  • PDF

A Study on the Electromagnetic shielding Effectiveness Using Conductive Polymers (전도성 고분자를 이용한 전자파 차폐효과의 연구)

  • 하남규;이보현;김태영;김종은;서광석
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.207-214
    • /
    • 2001
  • The conductive polymers, polyaniline (PANI) emeralidin base and 3,4-polyethylene dioxythiophene(PEDOT) were synthesized and coated on the PET film dealt with acryl type primer to study the electromagnetic shielding effectiveness. When both PANI and PEDOT were coated on the PET film dealt with acryl type priemer, their surface properties such as he adhesive increased. For PANI, when blended with the binder such as PMMA, it adhesive and surface hardness increased, too. The visible light transmittance decreased, while the electromagnetic shielding effectiveness increased, when coated thickness of PANI and PEDOT increased. For PANI, the electromagnetic shielding effectiveness increased as its surface resistance decreased. For PANI, when the surface resistance was 140 Ω/$\square$, the shielding effectiveness was found to be 11 dB in the far field, and 13 dB in the near field at 1 GHz. For PEDOT, when the surface resistance was 200 Ω/$\square$, the shielding effectiveness was found to be 3 dB in the far field, and 7dB in the near field.

  • PDF

Analysis of Electromagnetic Wave Absorbers for Applying Magnetic Levitation (자기부상체 적용을 위한 전자파 흡수체의 특성 분석)

  • Seo, Yong-beom;Kang, Hyun-il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • EMC (Electro Magnetic Compatibility) of the electrical railway must be ensured for safety of passenger. Maglev trains has not friction between the wheels and the rails because levitation by an permanent magnets, electromagnets and superconducting magnets etc. So, it is advantageous to maintain a high speed without noise and vibrations. In this paper, we investigated that the magnetic field of the before and after installation electromagnetic waves absorber in order to analyze the effects of electromagnetic waves. The theoretical analysis of the electromagnetic wave absorber was simulated using finite element method. The magnetic field properties of electromagnetic waves absorber were measured by EMI (Electro Magnetic Interference) test receiver.

Field Circuit Coupling Optimization Design of the Main Electromagnetic Parameters of Permanent Magnet Synchronous Motor

  • Zhou, Guang-Xu;Tang, Ren-Yuan;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.88-93
    • /
    • 2008
  • The electromagnetic parameters of a permanent magnet synchronous motor (PMSM) such as the open load permanent magnet flux, d axis reactance $X_d$, and q axis reactance $X_q$, are most essential to the performance analysis and optimization design of the motor. Based on the numerical analysis of the 3D electromagnetic field, the three electromagnetic parameters of permanent magnet synchronous motors with U form interior rotor structures are calculated by FEA. The rules of the leakage coefficient and reactance parameters changing with the air gap length, permanent magnet magnetism length, and isolation magnetic bridge dimensions in the rotor are given. The calculated values agree well with the measured values. The FEA results are integrated with the self compiled electromagnetic design program to optimize the prototype motor. The tested performances of the prototype motor prove that the method is suitable for the optimization of motor structure.