• Title/Summary/Keyword: Electrolytic cell

Search Result 128, Processing Time 0.028 seconds

An Electrolytic Treatment of Shipboard Sewage by Using DSA Electrode(II) -Continuous Electrolytic Treatment- (DSA 전극에 의한 선박오폐수의 전해처리(II))

  • 김인수;조권희;남청도
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.3 no.2
    • /
    • pp.77-84
    • /
    • 1997
  • For the effective treatment of shipboard sewage continuously, a non-diaphragm electrolytic treatment device using DSA type insoluble electrode, Ti/IrO2, anode and H-C metal cathode, was studied. The most effective electrolytic conditions were obtained when cell clearance, 6mm, pH 5-6 and the concentration of seawater, more than 20% as batch test results. The COD removal rate was varied in logarithmic function, showed as C=Coe-KE and the required current was E = A/QCo [A.min/mgCOD]. When the COD removal effeciency was more than 90%, the electrolytic reaction constant was 0.02.

  • PDF

A Study on Chemical Cleaning of Electrolytic Facilities with Sea Water (해수전해설비의 화학세정 최적화 방안에 관한 연구)

  • 이한철;이창우;현성호
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.114-119
    • /
    • 1999
  • When NaOCl was generated and put into sea-water cooling machine in order to overcome the biological hindrances against sea-water cooling machine, it was converted into metallic ion, particularly Ca and Mg, as a hydrate in sea-water and is to stick to electrolyte as a side reaction. This phenomena make the distance between the electrolytes narrow to decrease the flow rate, which induces the local vortex flow which erodes the pole plate. Moreover, this increases the resistance of the electrolyte as well as voltage to decrease the electrolytic efficiency, which has curtailed a chlorine yield and caused a pole plate cut. We are able to overcome these problems by chemical cleaning and intend to extend the life-time of electrolyte and to increase output of the sea-water electrolysis facilities by studying optimal policy regarding chemical cleaning of electrolytic cell. Cleaning time of electrolytic facilities is determined when both increase in electrolytic efficiency and decrease in pole-plate voltage are 10%. At this time as operating current of electrolytic facilities is high, operating time is diminished. Whereas, parameter of end point determination according to cleaning is Mg ionic concentration in solution. When we use Cleaner as a 7wt% HCl, cleaning time is about 80min proper. We are able to maintain pole plate performance by protecting against pole plate cut by means of electrolytic by-product, improve operating rate of facilities, and cut down on maintenance expenditure after acidic cleaning.

  • PDF

A Study on Control Disinfection By-products in High Sodium Hypochlorite Generation (고농도 차아염소산나트륨 발생장치의 소독부산물 제어에 관한 연구)

  • Cho, Haejin;Shin, Hyunsoo;Ko, Sungho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.183-189
    • /
    • 2017
  • Sodium hypochlorite used in water disinfection processes is generally in the production of chlorine to 0.8%. As the dose of chlorine increases, disinfection by-products (Chlorate) also increase simultaneously and exceed water quality standards. In this study, the electrolytic cell of a sodium hypochlorite generator (12% chlorine) was adjusted to control the production of the disinfection by-products. As a result, it was possible to reduce Chlorate concentrations by more than 95% by adjusting the pH of the electrolytic cell from 1.53 to 4.2 (normal pH of the electrolytic cell). As a low current is required to obtain these results, a 15% improvement in the efficiency of the positive electrode is also observed. For the development of High Sodium Hypochlorite Generation can be used in a safe sodium hypochlorite solution, which is expected to contribute to improvement in the safety of the disinfection process.

Effect of NaOCl and Gold Plating Additive on the Gold Recovery in Cyclone Electrolytic Cell from Solution for Stripping Gold of PCB by Cyanide (시안을 이용한 PCB 금 박리용액으로부터 사이클론 전해조에서의 금 회수거동에 미치는 차아염소산나트륨과 금 도금첨가제의 영향)

  • Jo, Hyeonji;Yoo, Kyoungkeun;Bae, Mooki;Sohn, Jeongsoo;Yang, Donghyo;Kim, Sookyung
    • Resources Recycling
    • /
    • v.26 no.4
    • /
    • pp.88-94
    • /
    • 2017
  • The recovery of gold in cyclone type electrolytic cell was conducted from solution for stripping gold of PCB by cyanide. The electrolytic recovery behaviors of gold was investigated by reaction time and addition of electrolytic sodium hypochlorite (NaOCl) and gold plating additive (KG-120). Because the electrolysis generated NaOCl reacted with the cyanide in the leachate by alkaline chlorination, more than 99% of the cyanide was removed at a $NaOCl(g)/CN^-(g)$ ratio of 1.0. When NaOCl was added during the recovery of the gold from cyanide leachate in the cyclone electrolytic cell, the recovery of gold was 98% at the ratio of $NaOCl(g)/CN^-(g)$ from 0.5 to 2.5 in 480 minutes and decreased rapidly over the ratio of 3.0. Gold was recovered more than 99% by adding 1.5 and 4.5%(v/v) of KG-120 with NaOCl in 480 minutes. In particular, when the concentration of KG-120 was 3.5 and 4.5%(v/v), more than 96% of gold was recovered within 240 minutes and the initial recovery rate was relatively faster. The optimum concentration of KG-120 is 3.5%(v/v) considering the economic feasibility and efficiency.

HOT CELL RENOVATION IN THE SPENT FUEL CONDITIONING PROCESS FACILITY AT THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE

  • YU, SEUNG NAM;LEE, JONG KWANG;PARK, BYUNG SUK;CHO, ILJE;KIM, KIHO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.776-790
    • /
    • 2015
  • Background: The advanced spent fuel conditioning process facility (ACPF) of the irradiated materials examination facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI) has been renovated to implement a lab scale electrolytic reduction process for pyroprocessing. The interior and exterior structures of the ACPF hot cell have been modified under the current renovation project for the experimentation of the electrolytic reduction process using spent nuclear fuel. The most important aspect of this renovation was the installation of the argon compartment within the hot cell. Method: For the design and system implementation of the argon compartment system, a full-scale mock-up test and a three-dimensional (3D) simulation test were conducted in advance. The remodeling and repairing of the process cell (M8a), the maintenance cell (M8b), the isolation room, and their utilities were also planned through this simulation to accommodate the designed argon compartment system. Results and conclusion: Based on the considered refurbishment workflow, previous equipment in the M8 cell, including vessels and pipes, were removed and disposed of successfully after a zoning smear survey and decontamination, and new equipment with advanced functions and specifications were installed in the hot cell. Finally, the operating area and isolation room were also refurbished to meet the requirements of the improved hot cell facility.

Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater (중금속폐수에서 구리의 전기화학적 침전처리)

  • 김재우;이재동;이우식;지은상
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

Synthesis of Cyclitol Derivatives (IV) Electrolytic Reduction of DL-epi-inosose-2 (Cyclitol 유도체 합성에 관한 연구 (제4보) DL-epi-inosose-2의 전해환원)

  • Sohn, Joo-Hwan;Nam, Chong-Woo;Park, Heung-Cho
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.93-99
    • /
    • 1972
  • To obtain the various kinds of inositol stereomers, we have selected the process of electrolytic reduction of DL-epi-inosose-2 using Ni, Ta, Cu, Mo, Pb, Sn, W, Cd and Hg etc., as cathode. We think that this process gives greater variety than chemical processes. DL-epi-inosose-2 was synthesized by chemical oxidation of myo-inositol, dissolved in aqueous solution of potassium hydroxide, and used as electrolytic solution. To prevent anodic oxidation of cathode products the H-type diaphragm cell was used. As the results of paper chromatography of cathodic products, we obtained the $R_f$ values of myo-inositol and epi-inositol were in good agreement with literature values.

  • PDF

Effective Electrolytic Water Generation Characteristics by Overlapped Multi-layer Electrode (중첩형 다단전극에 의한 효율적인 전해 이온수 발생 특성)

  • Shin, Dong-Hwa;Hwang, Deok-Hyun;Jung, Jae-Seung;Kim, Hyung-Pyo;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.59-64
    • /
    • 2016
  • Applications of electrolytic ion water generated by the oxidation-reduction have gradually been expanded due to their strong sterilizing power and a surface active force. We demonstrate the effect of the multi-layer type electrode for effective ion water generation. The multi-layer type electrode has ability to generate stronger acid and alkali water by increase of the electrode reactive area. Also power consumption efficiency enhances because the electrodes disposed in middle position of the reactive cell raise the usage rate by overlapped effect as an electrolysis electrode.

Etch Pit Growth on Aluminum of Cathode Film for Aluminum Electrolytic Capacitor (알루미늄 전해 커패시터용 음극박의 에칭 피트 성장)

  • Kim, Hong-Il;Choi, Ho-Gil;Kim, Sung-Han;Kim, Young-Sam;Shin, Jin-Sik;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.407-408
    • /
    • 2005
  • High surface area electrodes for aluminum electrolytic capacitors are produced by AC electrochemical processes. Optimization of crystallographic etch pit growth on aluminium during AC etching of cathode film for aluminium as electrolytic capacitor has been established. In this work, we present the observations of pit distributions by galvanostatic measurements. The effects of electrolyte concentration, current density, frequency, various pre-treatments and etching time have been studied. The specimen was pretreated in 0.5M NaOH and 1M HCl at $40\sim60^{\circ}C$, and transferred into a cell containing 1M HCl, then various mol $H_2SO_4$ etchant was added. Pit size distributions were determined with scanning electron microscopy (SEM).

  • PDF

An Anomaly Detection Algorithm for Cathode Voltage of Aluminum Electrolytic Cell

  • Cao, Danyang;Ma, Yanhong;Duan, Lina
    • Journal of Information Processing Systems
    • /
    • v.15 no.6
    • /
    • pp.1392-1405
    • /
    • 2019
  • The cathode voltage of aluminum electrolytic cell is relatively stable under normal conditions and fluctuates greatly when it has an anomaly. In order to detect the abnormal range of cathode voltage, an anomaly detection algorithm based on sliding window was proposed. The algorithm combines the time series segmentation linear representation method and the k-nearest neighbor local anomaly detection algorithm, which is more efficient than the direct detection of the original sequence. The algorithm first segments the cathode voltage time series, then calculates the length, the slope, and the mean of each line segment pattern, and maps them into a set of spatial objects. And then the local anomaly detection algorithm is used to detect abnormal patterns according to the local anomaly factor and the pattern length. The experimental results showed that the algorithm can effectively detect the abnormal range of cathode voltage.