• 제목/요약/키워드: Electrolysis water

검색결과 389건 처리시간 0.024초

수전해용 Pt/공유가교 SPEEK-HPA 복합막/Pt-Ru MEA의 전기화학적 특성 (The Electrochemical Characteristics of MEA with Pt/Cross-Linked SPEEK-HPA Composite Membranes/Pt-Ru for Water Electrolysis)

  • 황용구;우제영;이광문;정장훈;문상봉;강안수
    • 한국수소및신에너지학회논문집
    • /
    • 제20권3호
    • /
    • pp.194-201
    • /
    • 2009
  • The e1ectrocatalytic properties of heteropolyacids(HPAs) entrapped in covalently cross-linked sulfonated polyetheretherketone(CL-SPEEK/HPA) membranes have been studied for water electrolysis. The HPAs, including tungstophosphoric acid(TPA), molybdophosphoric acid(MoPA), and tungstosilicic acid(TSiA) were used as additives in the composite membranes. The MEA was prepared by a non-equilibrium impregnation-reduction(I-R) method, using reducing agent, sodium borohydride(NaBH4) and tetraamineplatinum(II) chloride(pt(NH$_3$)$_4$Cl$_2$). The electrocatalytic properties of composite membranes such as the cell voltage were in the order of magnitude CL-SPEEKlMoPA40 (wt%) > /TPA30 > /TSiA40. In the optimum cell applications for water electrolysis, the cell voltage of PtlPEM/Pt-Ru MEA with CL-SPEEKlTPA30 membrane was 1.75 V at 80$^{\circ}$C and I A/cm$^2$ and this voltage carried lower than that of 1.81 V of Nafion 117. Consequently, in regards of electrochemical and mechanical characteristics and oxidation durability, the newly developed CL-SPEEKITPA30 composite membrane exhibited a better performance than the others, but CLSPEEKlMoPA40 showed the best electrocatalytic activity (1.71 Vat 80$^{\circ}$C and 1 A/cm$^2$) among the composite membranes.

고분자 전해질 막을 이용한 일체형 재생 연료전지용 촉매전극 개발 (Development of Bifunctional Electrocatalyst for PEM URFC)

  • 임성대;박구곤;손영준;양태현;윤영기;이원용;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-31
    • /
    • 2004
  • For the fabrication of high efficient bifunctional electrocatalyst of oxygen electrode for PEM URFC (Polymer Electrolyte Membrane Unitized Regenerative Fuel Cell), which is a promising energy storage and conversion system using hydrogen as the energy medium, several bifunctional electrocatalysts were prepared and tested in a single cell URFC system. The catalysts for oxygen electrode revealed fuel cell performance in the order of Pt black > PtIr > PtRuOx > PtRu ~ PtRuIr > PtIrOx, whereas water electrolysis performance in the order of PtIr ~ PtIrOx > PtRu > PtRuIr > PtRuOx ~ Pt black. Considering both reaction modes PtIr was the most effective elctrocatalyst for oxygen electrode of present PEM URFC system. In addition, the water electrolysis performance was significantly improved when Ir or IrOx was added to Pt black just 1 wt.% without the decrease of fuel cell performance. Based on the catalyst screening and the optimization of catalyst composition and loading, the optimum catalyst electrodes for PEM URFC were $1.0mg/cm^2$ of Pt black as hydrogen electrode and $2.0mg/cm^2$ of PtIr (99:1) as oxygen electrode.

해수전해장치 전해조 개선에 의한 전극 부착물 저감 (Reduction of Deposits on the Electrode by the Cell Modification in Direct Sea Water Electrolysis System)

  • 박승수;김기형;안희수;박광규;이태원
    • 공업화학
    • /
    • 제16권4호
    • /
    • pp.563-569
    • /
    • 2005
  • 발전소에서 운영하고 있는 해수전해장치의 전극에 부착물이 다량으로 부착하여 성능이 저하되고 전극 손상사고가 발생하고 있어 전극 부착물을 억제할 수 있는 방안을 연구하였다. 현재 사용하고 있는 grating type의 양극을 plate type으로 변경하고 양극판 수를 9매에서 8매로 줄이는 한편, 전극 간격을 2.4 mm에서 3.0 mm로 늘리고, 극간 간격을 유지하기 위한 스페이서를 27개에서 10개로 줄인 전해조를 개발하였다. 발전소 현장에 개발 전해조를 설치하여 성능을 시험한 결과 기존의 제품에 비하여 전류효율은 15~20% 높았고, 전극 부착물은 36~60% 감소하였으며, 전력소비율은 20% 정도 낮은 것으로 나타났다.

PWM 전압제어로 생체에 필요한 알칼리 이온수의 농도(ph)변화에 관한 연구 (Study about a density (ph) change of an alkaline ion by PWM voltage control necessary for a living body)

  • 권윤중;이성창
    • 전자공학회논문지SC
    • /
    • 제41권6호
    • /
    • pp.37-42
    • /
    • 2004
  • 사람의 체질이 산성화로 변화되는 것을 막고 생체 밸런스를 유지하기위해 알칼리수를 인간의 인체에 공급할 필요가 있다. 알칼리수는 인체에 유익한 칼슘(Ca/sup +/), 칼륨(K/sup +/), 마그네슘(Mg/sup +/), 나트륨(Na/sup +/)등을 포함한 물로 되어있다. 이러한 알칼리수를 생성하기 위해서는 물을 전기분해하여 격막(격리된 특수막)을 통해 - 전극 쪽으로 미네랄들을 모아 생성한다. 물론 반대로 + 전극쪽으로는 염소(Cl), 인(P), 유황(S) 등의 - 이온을 띈 유기물들이 모여 산성수도 발생되어 다른 용도의 물로 사용할 수 있다. 이 전기분해 과정에서 - 극판과 + 극판에 PWM(pulse width modulation)전압을 Microprocessor를 이용하여 4종류의 PWM 전압을 구현하고, 전압별 ph농도 변화를 고찰해 보았다. 이와 같이 PWM제어를 이용하면 필요한 ph농도 값의 알칼리 이온수를 설정 값으로 하면 정확하게 얻을 것으로 예상된다.

SOEC에 과열기의 고온 스팀을 공급하는 Interface의 열전달에 관한 전산해석 (A CFD Analysis on Heat Transfer of High Temperature Steam through Interface with Superheater and SOEC for Hydrogen Production)

  • 변현승;한단비;박성룡;조종표;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.169-176
    • /
    • 2020
  • There is a growing interest in hydrogen energy utilization since an alternative energy development has been demanded due to the depletion of fossil fuels. Hydrogen is produced by the reforming reaction of natural gas and biogas, and the electrolysis of water. An solid oxide electrolyte cell (SOEC) is reversible system that generates hydrogen by electrolyzing the superheated steam or producing the electricity from a fuel cell by hydrogen. If the water can be converted into steam by waste heat from other processes it is more efficient for high-temperature electrolysis to convert steam directly. The reasons are based upon the more favorable thermodynamic and electrochemical kinetic conditions for the reaction. In the present study, steam at over 180℃ and 3.4 bars generated from a boiler were converted into superheated steam at over 700℃ and 3 bars using a cylindrical steam superheater as well as the waste heat of the exhaust gas at 900℃ from a solid refuse fuel combustor. Superheated steam at over 700℃ was then supplied to a high-temperature SOEC to increase the hydrogen production efficiency of water electrolysis. Computational fluid dynamics (CFD) analysis was conducted on the effects of the number of 90° elbow connector for piping, insulation types and insulation layers of pipe on the exit temperature using a commercial Fluent simulator. For two pre-heater injection method of steam inlet and ceramic wool insulation of 100 mm thickness, the highest inlet temperature of SOEC was 744℃ at 5.9 bar.

알칼라인 수전해용 Ni-Zn-Fe 전극의 산소 발생 반응 특성 (Study on Oxygen Evolution Reaction of Ni-Zn-Fe Electrode for Alkaline Water Electrolysis)

  • 이태경;김종원;배기광;박주식;강경수;김영호;정성욱
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.549-558
    • /
    • 2018
  • The overall efficiency depend on the overpotential of the oxygen evolution reaction in alkaline water electrolysis. Therefore, it is necessary to research to reduce the oxygen evolution overpotential of electrodes. In this study, Ni-Zn-Fe electrodes were prepared by electroplating and the surface area was increased by Zn leaching process. Electroplating variables were studied to optimize the plating parameters(electroplating current density, pH value of electroplating solution, Ni/Fe content ratio). Ni-Zn-Fe electrode, which is electroplated in a modified Watts bath, showed 0.294 V of overpotential at $0.1A/cm^2$. That result is better than that of Ni and Ni-Zn plated electrodes. As the electroplating current density of the Ni-Zn-Fe electrode increased, the particle size tended to increase and the overpotential of oxygen evolution reaction decreased. As reducing pH of electroplating solution from 4 to 2, Fe content in electrode and activity of oxygen evolution reaction decreased.

Effect of Ramping Rate on the Durability of Proton Exchange Membrane Water Electrolysis During Dynamic Operation Using Triangular Voltage Cycling

  • Hye Young Jung;Yong Seok Jun;Kwan-Young Lee;Hyun S. Park;Sung Ki Cho;Jong Hyun Jang
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.253-260
    • /
    • 2024
  • Proton exchange membrane water electrolysis (PEMWE) is an efficient method for utilizing renewable energy sources such as wind and solar powers to produce green hydrogen. For PEMWE powered by renewable energy sources, its durability is a crucial factor in its performance since irregular and fluctuating characteristics of renewable energy sources, especially for wind power, can deteriorate the stability of PEMWE. Triangular voltage cycle is well able to simulate fluctuating wind power, but its effect on the durability has not been investigated extensively. In this study, the performance degradation of the PEMWE cell operated with the triangular voltage cycling was investigated at different ramping rates. The measured current responses during the cycling gradually decreased for both ramping rates, and I-V curve measurements before and after the cycling confirmed the degradation of the performances of PEMWE. For both measurements, the degradation rate was larger for 300 mV s-1 than 30 mV s-1, and they were determined as 0.36 and 1.26 mV h-1 (at the current density of 2 A cm-2) at the ramping rates of 30 and 300 mV s-1, respectively. The comparison with other studies on triangular voltage cycling also indicate that an increase in the ramping rate accelerates the deterioration of the PEMWE performance. X-ray photoelectron spectroscopy and transmission electron microscopy results showed that the Ir catalyst was oxidized and did not dissolve during the voltage cycling. This study suggests that the ramping rate of the triangular voltage cycling is an important factor for the evaluation of the durability of PEMWE cells.

알칼리 수전해 적용을 위한 하이브리드 다공성 격리막 제조 및 특성평가 (Preparation and Evaluation of Hybrid Porous Membrane for the Application of Alkaline Water Electrolysis)

  • 한성민;임광섭;정하늘;김도형;남상용
    • 멤브레인
    • /
    • 제31권6호
    • /
    • pp.443-455
    • /
    • 2021
  • 본 연구에서는 낮은 막 저항을 가지는 알칼리 수전해 시스템 적용을 위한 격리막 제조를 위하여 PPS (Polyphenylene sulfide)를 지지체로 사용하고 Polysulfone과 무기물 첨가제를 이용하여 격리막을 제조한 뒤, 지지체의 두께와 다공도에 대한 영향을 분석하였다. 지지체로 사용된 PPS 펠트를 온도(100℃, 150℃, 200℃)와 압력(1톤, 2톤, 3톤, 5톤)의 변수를 두어 압축을 진행하여 두께를 조절하고자 하였으며, 무기입자로서 친수성이 높고 내알칼리성이 뛰어난 BaTiO3와 ZrO2를 사용하여 polysulfone과 함께 슬러리를 제조하고 압축한 PPS 펠트 위에 캐스팅하여 다공성 격리막을 제조할 수 있었다. 전자주사현미경(SEM)을 통해 압축 조건에 따른 분리막의 모폴로지 변화를 확인하고, 기공도를 계산하였으며, 압축 조건이 증가할수록 두께와 기공도가 감소하는 경향을 확인하였다. 수전해용 격리막으로서 사용이 가능한지를 확인하기 위하여 다양한 특성 평가를 진행하였다. 기계적강도를 측정한 결과 압축 조건(온도와 압력)이 증가할수록 인장강도가 점차 증가하는 경향을 확인하였다. 최종적으로 내알칼리성 테스트를 통하여 제조한 다공성 격리막이 우수한 내알칼리성을 가지는 것을 확인하였고, I-V 테스트를 통하여 100℃와 150℃ 조건에서 압축된 막들이 기존의 압축하지 않은 막보다 낮은 전압을 가지며 성능이 향상되었다는 것을 확인하였다.

Enhanced Activity for Oxygen Evolution Reaction of Nanoporous IrNi thin film Formed by Electrochemical Selective Etching Process

  • Park, Shin-Ae;Shim, Kyubin;Kim, Kyu-Su;Moon, Young Hoon;Kim, Yong-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권4호
    • /
    • pp.402-407
    • /
    • 2019
  • Water electrolysis is known as the most sustainable and clean technology to produce hydrogen gas, however, a serious drawback to commercialize this technology is due to the slow kinetics in oxygen evolution reaction (OER). Thus, we report on the nanoporous IrNi thin film that reveals a markedly enhanced OER activity, which is attained through a selective etching of Os from the IrNiOs alloy thin film. Interestingly, electrochemical selective etching of Os leads to the formation of 3-dimensionally interconnected nanoporous structure providing a high electrochemical surface area (ECSA, 80.8 ㎠), which is 90 fold higher than a bulk Ir surface (0.9 ㎠). The overpotential at the nanoporous IrNi electrode is markedly lowered to be 289 mV at 10 mA cm-2, compared with bulk Ir (375 mV at 10 mA cm-2). The nanoporous IrNi prepared through the selective de-alloying of Os is promising as the anode material for a water electrolyzer.

출력 커패시터가 없는 위상천이 풀브릿지 컨버터의 전류 전향 보상을 이용한 출력 전압 제어 기법 (Output Voltage Control Technique Using Current Forward Compensation for Phase Shifted Full Bridge Converter Without Output Capacitor)

  • 신유승;백승우;김학원;조관열;강정원
    • 전력전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.40-47
    • /
    • 2022
  • At present, the low-voltage, high-current type power supply is mainly used for effective sterilization in the ballast water treatment system. Research on PSFB converters without output capacitors has been ongoing. Such converters effectively treat ballast water without a separate disinfectant through electric pulses by applying a pulse-type power to the output electrode without an output capacitor. However, in the case of the pulse-type electrolysis treatment method, voltage overshoot can occur due to abrupt voltage fluctuations when the load changes, resulting in circuit reliability problems because of the output capacitorless system. Therefore, a new voltage control algorithm is required. In this paper, we will discuss voltage control for pulsed electrolysis topology without an output capacitor. The proposed voltage control method has been verified using Simulation and experiment. The usefulness of the proposed control method has been proven by the experimental results.