• Title/Summary/Keyword: Electrodeless

Search Result 175, Processing Time 0.038 seconds

A Review of power supply technology of Electrodeless lamps (무전극램프 전원장치에 대한 기술동향)

  • Park S.;Han S.;Jeong H.;Jung B.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.826-829
    • /
    • 2004
  • This paper reviews electrodeless lamp technology. The lamp has very long life time but very high cost compared to conventional lamps such as fluorescent lamp. For optimizing the overall system in performance and cost, power supply as well as lamp is very important. First, this paper describes various electrodeless lamps and its market condition. Then, a lot of circuit technology for constructing the power supply is reviewed and circuit characteristics are discussed.

  • PDF

Brightness Property by Ferrite on Electroness Flurescent Lamp (무전극 형광램프용 페라이트에 따른 휘도특성)

  • Pack, Gwang-Hyeon;Lee, Jong-Chan;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.607-610
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie propertye of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. Coill turn was changed from 13th to 13th turn to recognize brightness change of lamp by winding number. Optical equipment that used in an experiment was used to measure brightness (LS-100). When an electrodeless fluorescent ]amp was made using and T company's PE22, was it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

  • PDF

The research for the luminous flux variation of electrodeless fluorescent lamp system as a voltage drop and short interruption (전압변동 및 순간정전에 따른 무전극 형광등 시스템의 광속변화에 대한 연구)

  • Shin, Sang-Wuk;Kim, Hyun-Sook;Lee, Se-Hyun;Hwang, Myung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.207-210
    • /
    • 2002
  • In this paper, We have measured the luminous flux variation of electrodeless fluorescent lamp system reducing a power source to 70% and applying a short interruption caused by the power failure. So we can understood that the protective device for apparatus of power sources is important thing to control electrodeless fluorescent lamp system.

  • PDF

Optical E-H Transition Properties of Inductively Coupled Plasma with Ar Gas Pressure and RF Pourer (Ar 가스 압력과 RF 전력변화에 따른 유도결합형ㆍ플라즈마 E-H모드 변환의 광학적 특성)

  • 허인성;조주웅;이영환;김광수;최용성;박대희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.20-23
    • /
    • 2004
  • In this paper, the emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma. To transmit the electromagnetic energy into the chamber, a RF power of 13.56 [MHz] was applied to the antenna and considering the Ar gas pressure and the RF electric power change, the emission spectrum, Ar I line, luminance were investigated. At this time, the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10∼60 [mTorr], 10∼300 [W], respectively. From emission intensity and lumnance intensity results, the mode transition from E-mode to H-mode was observed. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

A Study on the Sensibility Evaluation on the Color Temperatures of Electrodeless HID Lamp (무전극 HID 램프의 색온도 감성평가에 관한 연구)

  • Pak, Hyensou;Park, Bonjour;Jang, Woojin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.9-15
    • /
    • 2014
  • An experiment was carried out to evaluate the emotion and sensibility evoked from the different color temperatures(CCT) of electrodeless HID (ELHID) lamp. For this purpose, three ELHID lamps and a metal halide lamp were used as the experimental light sources and thirty Korean adjectives related to the lighting affectiveness were selected for the evaluation. The results showed that ELHID lamps induced different sensibilities according to their color temperature. In particular, 6500 K ELHID was similar to metal halide which has the CCT of 5600 K in the evaluation. Based on the results, we suggested some Korean adjectives and their corresponding English ones which are thought to be suitable for the verbal descriptions of ELHID lamps.

Self Reversal Effect of the High-pressured Diatomic Sulfur in the Electrodeless Sulfur Discharge Lamp (무전극 황방전등에서 고압 이원자 황($S_2$)의 자체 역전 효과)

  • Chu, Jang-Hee;Goo, Sun-Geun;Park, Ki-Jun;Yi, Young-Woo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.609-615
    • /
    • 2000
  • A prototype electrodeless sulfur lamp was developed and investigated the spectroscopic characteristics. The emission spectra of $S_2$ in the microwave-discharged eletrodeless sulfur lamp (ESL) were studied at various input power. The emission spectra of the ESL shift to longer wavelength with increasing of the input power. We have shown that this is due to the self reversal effect in the high pressure gas discharge. We also show that the self reversal effect increases as the rotation of the discharged bulb. The spectral distribution of the ESL shifts about 45 nm toward visible region from UV region due to the rotation of the lamp bulb.

  • PDF

Characteristic Change of Electrodeless Sulfur Lamp Induced by Adding of Nal (전구내 NaI 첨가에 의한 무전극 황전등의 특성 변화)

  • Goo, Sun-Geun;Park, Gi-Jun;Chu, Jang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.724-729
    • /
    • 1999
  • We developed the correlated color temperature (CCT) control technique for electrodeless sulfur lamp (ESL) by adding a few milligrams of NaI into sulfur discharge bulb. Nal produces intense Na D-line that changes the CCT of the ESL. We can adjustthe CCT in the range of 8,400 K to 3,600 K. Color rendering index can be maintained between 79 and 90 for the adjustable range of the CCT. the NaI helps the ESL dischargeable at below 0.5 kW of forward microwave power into the bulb. We have shown that this technique did not cause reduction of luminance compared to electrodeless elemental sulfur lamp.

  • PDF

A Study on the Standards of High Efficiency Electrodeless Fluorescent Lamps (고효율 무전극 형광등 시스템의 표준화에 관한 연구)

  • Cho, M.R.;Shin, S.W.;Lee, S.H.;Hwang, M.K.;Lee, D.Y.;Yang, S.Y.;Ham, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1667-1668
    • /
    • 2006
  • Electrodeless fluorescent lamps don't have standards yet. So we study applicable standards of electrodeless fluorescent lamps and analyze evaluation items and test method. Then we will use this paper basic information of standards.

  • PDF

Impedence and Q-factor of frequence dependance accoding to ferrites on electrodeless fluorescent lamp (무전극 형광램프의 주파수에 따른 임피던스 및 Q-factor 변화 연구)

  • Pack, Gwang-Hyoen;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Jong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.153-156
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined resistance kind, impedance, Q-factor's frequency characteristic by ferrite. Impedance, resistance and capacitance did not show difference in start frequency 2.65 [MHz] but there was difference quantity. We could know Q-factor's difference according to material, and Q-factor's is important part of antenna design.

  • PDF

Electric & Optical Characteristics of Electrodeless Fluorescent Lamp by Changing Ferrite Position (무전극 형광램프의 페라이트 위치변화에 따른 전기적, 광학적 특성)

  • Lee, Joo-Ho;Yang, Jong-Kyung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.244-245
    • /
    • 2007
  • The RF inductive discharge of inductively couples plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. Although most practical ICPs operate at 13.56 [MHz] and 2.65 [MHz], the trend to reduce the operating frequency is clearly recognizable from recent ICP developments. in and electrodeless fluorescent lamp, the use of a lower operating frequency simplifies and reduces cost of RF matching systems and RF generators and can eliminate capacitive coupling between the inductor coil and plasma, which could be a strong factor in wall erosion and plasma contamination. In this study, electric and optical characteristics of electrodeless fluorescent lamp by changing ferrite position is discussed.