• 제목/요약/키워드: Electrode-Plate

검색결과 398건 처리시간 0.03초

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

불평등 전계에서 변압기 절연유 절연파괴 연구 (Study on the Breakdown of the Transformer Insulating Oil in Nonuniform Electric Field)

  • 조하영;이순형;황미용;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권3호
    • /
    • pp.280-285
    • /
    • 2023
  • A breakdown voltage and breakdown electric field of the transformer insulating oil of liquid dielectric were studied in uniform electric field and non-uniform electric field and the transformer insulating oil was observed by the process reached breakdown. Insulation performance evaluation of the liquid dielectric was evaluated at the electrode spacing of 2.5 mm under the conditions of domestic and international standards (KS C IEC 60156), so a comparative review was conducted at the electrode spacing of 2.5 mm. When the electrode spacing is 2.5 mm, the average breakdown voltage is 38.5 kV for sphere-sphere electrodes, 26.6 kV for plate-plate electrodes, 22.9 kV for needle-needle electrodes, and 24.3 kV for sphere-needle electrodes. 23.7 kV for the sphere-plate electrode, and 20.7 kV for the needle-plate electrode. From these results, it can be seen that the average value of the breakdown voltage at the electrode spacing of 2.5 mm, in ascending order, is sphere-sphere, plate-plate, sphere-needle, sphere-plate, needle-needle and needle-plate. It was found that the breakdown voltage of the unequal field was lower than that of the equal field.

Photoactive Layer Formation with Oven Annealing for a Carbon Electrode Perovskite Solar Cell

  • Kim, Kwangbae;Song, Ohsung
    • 한국재료학회지
    • /
    • 제30권11호
    • /
    • pp.595-600
    • /
    • 2020
  • The photovoltaic properties of perovskite solar cells (PSCs) with a carbon electrode fabricated using different annealing processes are investigated. Perovskite formation (50 ℃, 60 min) using a hot-plate and an oven is carried out on cells with a glass/fluorine doped TiO2/TiO2/ZrO2/carbon structure, and the photovoltaic properties of the PSCs are analyzed using a solar simulator. The microstructures of the PSCs are characterized using an optical microscope, a field emission scanning electron microscope, and an electron probe micro-analyzer (EPMA). Photovoltaic analysis shows that the energy conversion efficiency of the samples fabricated using the hot-plate and the oven processes are 2.08% and 6.90%, respectively. Based on the microstructure of the samples and the results of the EPMA, perovskite is formed locally on the carbon electrode surface as the γ-butyrolactone (GBL) solvent evaporates and moves to the top of the carbon electrode due to heat from the bottom of the sample during the hot plate process. When the oven process is used, perovskite forms evenly inside the carbon electrode, as the GBL solvent evaporates extremely slowly because heat is supplied from all directions. The importance of the even formation of perovskite inside the carbon electrode is emphasized, and the feasibility of oven annealing is confirmed for PSCs with carbon electrodes.

Energy Efficiency Improvement of Vanadium Redox Flow Battery by Integrating Electrode and Bipolar Plate

  • Kim, Min-Young;Kang, Byeong-Su;Park, Sang-Jun;Lim, Jinsub;Hong, Youngsun;Han, Jong-Hun;Kim, Ho-Sung
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권3호
    • /
    • pp.330-338
    • /
    • 2021
  • An integral electrode-bipolar plate assembly, which is composed of electrode, conductive adhesive film (CAF) and bipolar plate, has been developed and evaluated for application with a vanadium redox flow battery (VRB) to decrease contact resistance between electrode and bipolar plate. The CAF, made of EVA (ethylene-vinyl-acetate) material with carbon black or CNT (Carbon Nano Tube), is applied between the electrode and the bipolar plate to enable an integral assembly by adhesion. In order to evaluate the integral assembly of VRB by adhesive film, the resistivity of integral assembly and the performance of single cell were investigated. Thus, it was verified that the integral assembly is applicable to redox flow battery. Through resistance and contact resistance of bare EVA and CAF films on bipolar plate were changed. Among the adhesive films, CAF film coated with carbon black showed the lowest value in through resistance, and CAF film coated with CNT showed the lowest value in contact resistance, respectively. The efficiency of VRB single cell was improved by applying CAF films coated with carbon black and CNT, resulting in the reduced overvoltage in charging process. Therefore, the energy efficiency of both CAF films, about 84%, were improved than that of blank cell, about 79.5 % under current density at 40 mA cm-2. The energy efficiency of the two cells were similar, but carbon black coated CAF improved the coulomb efficiency and CNT coated CAF improved the voltage efficiency, respectively.

수조모델 실험에 의한 접지저항 추정 (presumption of Earth Resistance by Water Tank Model)

  • 고희석;최종규;김주찬;이충식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.125-131
    • /
    • 2002
  • It is very important to assume potential distribution to be generated in electrode environs and grounding resistance by current beforehand, when incoming at grounding electrode to plan efficient grounding facilities In this paper, we analyzed grounding resistance through a simulation experiment by a water tank scaled model electrode of the rectangular earth plate, a theoretical Calculation result of the rectangular earth plate and measurement of grounding resistance buried rectangular earth plate analysing earth surface potential.

  • PDF

전기분해를 이용한 크롬과 아연함유 폐수처리 (Treatment of Wastewater containing Cromium and Zinc by Electrolysis)

  • 김재용;엄명헌
    • 환경위생공학
    • /
    • 제16권3호
    • /
    • pp.87-95
    • /
    • 2001
  • We've been investegated to find the optimum operation condition of electrlysis which have an influance on disposal efficiency of heavy metals. When we electrolyzed the testing wastewaters containing each 250mg/L of Cr and Zn ions, we exerimented with using variables like as pH, NaCl, electrode gap, electric current strength, the number of electrodes, after fastening positive electrode plate with Al, Fe, Ti and negative electrode plate with Stainless Steel Plate.

  • PDF

고체 유전율 측정용 cell의 불확도 분석과 보상 (Uncertainty and Compensation on the cell for Measurement of the Solid Permittivity Materials)

  • 김한준;강전홍;유광민;이세현;구경완;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.482-483
    • /
    • 2007
  • For measurement of dielectric constants, the commercial parallel plate electrodes system with guard-ring electrode have been widely used up to now. The capacitance derived from the parallel plate electrodes capacitor with guard-ring electrode is calculated by the equation of ($C={\epsilon}\;{\cdot}\;\frac{area\;of\;electrod}{distance\;between\;electrodes}$). Therefore, in parallel plate electrode capacitor, the diameter of the guarded electrode, the gap size between guarded electrode and guard ring, and distance between two active electrode should be measured precisely to calculate dielectric constants from the measured capacitance. Consequently their mechanical measurement uncertainties are directly contributed. Especially the air-gap between the electrodes and dielectric specimen at the system must be existed and the measurement error derived from the air-gap is impossible to evaluate as measurement uncertainties. In this study, we analyze the uncertainty of the commercial dielectric constant test cell using 3 kinds CRMs.

  • PDF

병렬판상전극의 수조모델 시뮬레이션 해석 (Analysis for Water tank model simulation of parallel plate electrodes)

  • 고희석;김성삼;이충식;최종규;류희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.280-282
    • /
    • 2003
  • In this paper we tried to analyze through the water tank model to solve these kinds of problems about the square plate earth electrode using general facilities with being compared with the theory formula announced before. The square plate earth electrode that haven't investigated so far is analyzed by being based on laid rod electrode. And the each kind of calculation model was investigated with the experiment of water tank. An experiment of the vertical square Plate electrode about laying depth in the center of the surface of the water has already done with the practical models that have different forms of electrodes.

  • PDF

이동 전극형 전기집진기의 집진특성에 관한 연구 - I. 집진판 이동 속도의 영향- (A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - I. Effect of Collection Plate Velocity -)

  • 김용진;하병길;정상현;문상철;유주식
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.901-907
    • /
    • 2004
  • This study investigate the effect of collection plate velocity on the electrical and collection characteristics of a moving electrode electrostatic precipitator (MEEP). Though a high resistivity fly ash is attached at the collecting electrode, the MEEP has very stable characteristics of voltage and corona current. Collection efficiency, corona current, and overall collection efficiency are increased, as the magnitude of the collection plate velocity increases.

활성탄전극의 분진제거에 대한 기초연구 (Preliminary Study on Dust Removal by Electrode-Plate Coated with Activated Carbon)

  • 김광수;박현철;전태환;이주행;김일호
    • 대한환경공학회지
    • /
    • 제35권10호
    • /
    • pp.749-755
    • /
    • 2013
  • 본 연구의 목적은 분진제거를 목적으로 제작된 활성탄 전극의 적정 간격 및 적정 전압 그리고 분진 제거효율을 통하여 전극의 적정한 배열에 대하여 알아보고자 수행하였다. 여러 전극 간격 별로 수행한 실험결과로부터 분진의 부착 및 탈착의 빈도수는 전극의 간격이 가까워질수록 증가하였다. 전극 단위면적 당 분진 부착량은 전극간격이 멀어질수록 증가하였지만 총 부착량에 있어서는 전극간격이 가까울수록 전극의 설치수가 많아져서 증가하였다. 이와같은 실험결과로부터 분진제거 챔버에서 전극의 설치간격은 앞단의 경우는 분진 부하량이 높기 때문에 제거량이 많도록 전극의 간격을 멀리하고 후단은 제거효율을 높이기 위하여 전극간격을 가깝게 설치하는 것이 바람직하다고 사료되었다. 그리고 전압 5 kV, 전극간격 2 cm에서 전압의 변화에 따른 분진부착량 실험결과에서 전압의 변화와 부착량과는 상관관계가 없었다.