• 제목/요약/키워드: Electrode designs

검색결과 32건 처리시간 0.03초

Evaluation of Mixing Performance in Several Designs for Microfluidic Channel Mixers

  • 왕양양;서용권;강상모
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2811-2816
    • /
    • 2007
  • We conducted a numerical study of AC-electroosmotic (alternating current) effect on the fluid flow and mixing in a 3-D microchannel. The microchannel used as an efficient micro-mixer is composed of a channel and a series of pairs of electrodes attached in zigzag pattern on the bottom wall. The AC electric field is applied to the electrodes so that a steady flow current takes place around the electrodes. This current is flowing across the channel and thus contributing to the mixing of the fluid within the channel. We performed numerical simulations by using a commercial code to obtain a steady flow field. This steady flow is then used in evaluation of the mixing performance via the concept of mixing index. It was found that good combination of two kinds of electrode, which gave us a good mixing, is not simple harmonic. And when the length ratio of these two kinds of electrode is 2:1, we can get the best mixing effect.

  • PDF

New PDP cell designs for high luminous efficiency and radiation transport model in PDP

  • Yang, Sung-Soo;Shin, Seung-Won;Kim, Hyun-Chul;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.590-593
    • /
    • 2002
  • Using two- and three-dimensional fluid simulation codes, we have suggested several new plasma display panel (PDP) cell structures that have high luminous efficiency compared with conventional structure. To improve the luminance and discharge efficiency, we utilize long discharge path, lower electric field region, and reduction of power consumption by adding one auxiliary electrode or reducing the electrode area. Consequently, luminous efficiency increases about 1.8 times. Furthermore for the resonance radiation trapping effect in PDP system, we have described a self-consistent radiation transport model coupled with fluid simulation using modified Holstein's equation.

  • PDF

리튬 이온 배터리용 양극 및 음극 재료의 최근 동향 (Recent Advances in Cathode and Anode Materials for Lithium Ion Batteries)

  • 누엔반히엡;김영호
    • 공업화학
    • /
    • 제29권6호
    • /
    • pp.635-644
    • /
    • 2018
  • 리튬 이온 배터리는 휴대용 전자 제품, 전기 자동차 및 그리드 규모의 에너지 저장 장치 등과 같이 일상 생활에서 다양한 용도로 널리 사용되고 있다. 최근 높은 에너지 밀도, 경량 및 저비용과 같은 상업적 요구를 만족하는 리튬 이온 배터리 전극 소재 개발을 위하여 상당한 노력이 진행되어 오고 있다. 이 총설에서는 리튬 이온 배터리 양극 및 음극 재료의 원리와 최근 연구 동향을 요약하였으며, 특히 전극 소재의 설계 및 고급 특성화 기술을 강조하였다.

High Xe-content PDP

  • Oversluizen, G.;Dekker, T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.55-58
    • /
    • 2004
  • High Xe-content PDP characteristics are discussed. A high efficacy, up to 5 lm/W for a 50% Xe in Ne gas mixture, is realized in 4-inch color PDP test panel designs with low cost stripe-type barrier rib structures, that are powder blasted in soda lime glass. Furthermore, for a high Xe-content a high luminance can be obtained with a relatively small electrode area. Therefore the inter cell gap and the driving margin can be increased in a stripe-type barrier rib structure. Finally, for a high Xe-content the panel lifetime increases, due to increasing luminance and firing voltage stability. Clearly, these findings may direct the design development for next generation PDPs towards a high Xe-content

  • PDF

인간 피부에 삽입형 전극설계를 위한 생체임피던스 특성 (Characteristics of Bio-impedance for Implantable Electrode Design in Human Skin)

  • 김민수;조영창
    • 한국산업정보학회논문지
    • /
    • 제19권4호
    • /
    • pp.9-16
    • /
    • 2014
  • 전극 접촉저항은 생리학적 측정에 중대한 인자이며, 전기적 임피던스 측정을 수행할 때 정확성에 제한적 요인이 될 수 있다. 생체전기임피던스 값들은 인간피부에 삽입되는 전극을 이용하여 하부 조직의 도전율과 유전율에 의해서 계산할 수 있다. 본 연구에서는 피지, 각질층, 표피층, 진피, 피하조직 및 근육층의 인체 피부의 생리적 변화를 검출하는데 주안점을 두고 있으며, 피하조직에 삽입되는 전극의 최적설계를 위해 유한요소법을 사용하였다. 이를 위해 전극의 길이(50 mm, 70 mm), 재질(금), 모양(직사각형, 둥근사각, 육각기둥) 및 깊이(22.325 mm)에 따른 전극설계의 차이를 유한요소법을 통해 피하조직 층으로부터 얻어지는 정보를 바탕으로 기하학적으로 평가하였다. 생체임피던스 실험에서 전극모양과 인가전압에 따라서 피하조직에서 생체임피던스 차이가 가장 크게 나타남을 확인하였다. 본 연구의 모의실험은 피부의 전기적 임피던스 측정과 해석에 관한 물리적 현상뿐만 아니라 다른 형태의 전극 설계에 관한 특성들을 설명할 수 있을 것이다.

도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구 (A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels)

  • 구태용;김용민;홍정희;황정호
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

생체신호 측정을 위한 기능성 의류의 디자인 연구 -심전도 센싱 의류를 중심으로- (A Study on the Design of Functional Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing-)

  • 조하경;송하영;조현승;구수민;이주현
    • 감성과학
    • /
    • 제13권3호
    • /
    • pp.467-474
    • /
    • 2010
  • 최근 생체 신호 측정을 위한 기능성 의류는 동작 잡음에 의한 노이즈를 최대한 줄여 정확한 생체 신호를 측정 가능케 하는 것의 중요성에 대한 논의가 이루어지고 있다. 이에 본 연구는 영향 요인별 고려 사항을 반 영하여 3-리드(lead)방식의 은사 자수의 직물 전극을 개발하고, '일자형 절개 타입', '십자형절개 타입', '엑스형 절개 타입', '곡선 엑스형 절개 타입'의 총 네 가지 타입의 생체신호 센싱 스마트 의류의 시안을 설계하고 제작하였다. 디자인 시안은 민소매형태의 남성용 티셔츠로 신축성 있는 소재를 사용하여 인체 굴곡을 따라 의복과 전극이 밀착될 수 있도록 하였으며, 트랜스미터를 이용하여 메인 컴퓨터로 데이터가 무선 전송되게 하였다. 각 재모듈화형 의류 타입별 인체 동작에 의한 영향과 정지 및 동작 상태에서의 심전도 센싱 성능을 평가하기 위해 동작에 따른 전극의 변위를 측정하고, 심전도 측정 평가를 실시하여 SNR을 분석하였다. 본 실험 결과를 반영하여 의류 디자인 시안의 수정 및 보완 과정을 거친 후, 최종적으로 '연속-부착형', '삽입-분리형'의 두 가지 타입의 생체신호 센싱 스마트의류 디자인 모형의 모듈화 방안을 제시하였다.

  • PDF

A Fully Optimized Electrowinning Cell for Achieving a Uniform Current Distribution at Electrodes Utilizing Sampling-Based Sensitivity Approach

  • Choi, Nak-Sun;Kim, Dong-Wook;Cho, Jeonghun;Kim, Dong-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.641-646
    • /
    • 2015
  • In this paper, a zinc electrowinning cell is fully optimized to achieve a uniform current distribution at electrode surfaces. To effectively deal with an electromagnetically coupled problem with multi-dimensional design variables, a sampling-based sensitivity approach is combined with a highly tuned multiphysics simulation model. The model involves the interrelation between electrochemical reactions and electromagnetic phenomena so as to predict accurate current distributions in the electrowinning cell. In the sampling-based sensitivity approach, Kriging-based surrogate models are generated in a local window, and accordingly their sensitivity values are extracted. Such unique design strategy facilitates optimizing very complicated multiphysics and multi-dimensional design problems. Finally, ten design variables deciding the electrolytic cell structure are optimized, and then the uniformity of current distribution in the optimized cell is examined through the comparison with existing cell designs.

Development of High-Definition PDP TV with High-Efficient Hexagonal Array Structure

  • Lee, Byung-Hak;Heo, Eun-Gi;Yoon, Cha-Keun;Lee, Kwang-Sik;Cho, Yoon-Hyoung;Yoo, Min-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.347-350
    • /
    • 2003
  • Optimization of the luminance, luminous efficiency, and address voltage margin characteristics has been made on the delta color array PDP with various hexagonal shape subpixels. The optimal subpixel and electrode designs are obtained for the 42-inch high-definition PDP ($1,366{\times}768$) with the fine pixel pitch less than 0.7 mm. The hexagonal delta array structure shows more improved characteristics than that of the normal delta array structure with rectangular shape subpixels.

  • PDF

DSSC광전극의 나노구조 제어 및 투명전극 소재 개발

  • 장현석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.28-28
    • /
    • 2010
  • Photoelectrochemical solar cells such as dye-sensitized cells (DSSCs), which exhibit high performance and are cost-effective, provide an alternative to conventional p-n junction photovoltaic devices. However, the efficiency of such cells plateaus at 11-12%, in contrast to their theoretical value of 33%. Improvements in efficiency can only occur through a fundamental understanding of the underlying physics, materials, and device designs of DSSCs. A photoelectrode consisting of semiconducting oxide nanoparticles and a transparent conducting oxide electrode (TCO) is a key component of DSSC and design of photoelectrode materials is one of promising strategies to improving energy conversion efficiency. We introduce monodisperesed $TiO_2$ nanoparticles prepared by forced hydrolysis method and their superiority as photoelectrode materials was characterized with aids of optical and electrochemical analysis. Multi-layered TCO materials are also introduced and their feasibility for use as photoelectrodes is discussed in terms of optical absorption and charge collecting properties.

  • PDF