• Title/Summary/Keyword: Electrode bar

Search Result 70, Processing Time 0.031 seconds

Partial Discharge Characteristics of XLPE According to Electrode Shape and Void (전극형상 및 보이드에 따른 XLPE의 부분방전 특성)

  • Shin, Jong-Yeol;Kim, Guin-sik;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.50-57
    • /
    • 2016
  • Transmission equipment is mainly used for the XLPE (cross-linked polyethylene) insulation cable for ultra high voltage power to minimize power loss. The experiment examined the partial discharge characteristics according to the insertion of the bar electrode and needle electrode into the XLPE specimen and the air voids. XLPE insulation cable manufactured by T. company and tungsten electrode material by K. company were used for specimens, by adhering conductive tape on the semi-conductive material of the lower electrode of XLPE specimen with the dimension of $16{\times}40{\times}30$ [mm] was used as negative electrode. In order to investigate the PD with ${\phi}$-q-n of XLPE specimen according to the electrode shape and the size of air voids. we examined the PD by varying the voltage after applying voltage of 3~20 kV on the electrode. Therefore, it was confirmed from the result of PD characteristics of specimen that the larger the air void than the gap between electrode (+) and electrode(-), the larger effect on the discharge when the bar electrode and needle electrode inserted into XLPE, and the closer the distance between the insulation and the needle electrode, the faster insulation breakdown.

Probing of Steel Bar Location inside Concrete using Multi-electrode Array (다전극 배열을 이용한 콘크리트 매립 철근의 위치탐사)

  • 이형우;임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.663-666
    • /
    • 2003
  • Using numerical analysis modeling of Multi-electrode Array that could be applied to the corrosion state measurement of a reinforcing steel bar in concrete, the steel bar location inside concrete can be probed by the investigation of the change of the measured impedance from concrete surface determined by the electrical impedance of interface between the steel bar and concrete, the electrical resistivity of concrete, the array of electrodes and the relative location and diameter of the steel bar.

  • PDF

Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance (기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

Sensory Nerve Conduction Velocity of Median Proper Palmar Digital Nerve Recorded by Bar Electrode (막대전극을 이용하여 기록한 정중고유손바닥쪽 손가락신경의 감각신경전도속도)

  • Kwak, Kyo Ho;Lee, Dong Kuck
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.1
    • /
    • pp.21-26
    • /
    • 2000
  • Background: There has been few electrophysiologic studies in median proper palmar digital nerve(PPDN). Bar electrode may be a useful tool to evaluate the pathophysiologic state of the distal peripheral nerves. Objectives : To evaluate sensory nerve conduction velocities(NCVs) of median PPDNs in normal controls and carpal tunnel syndrome(CTS) patients by bar electrode, and clarify the usefulness of the bar electrode. Methods : We checked NCV of each median PPDN of thumb(D1), index(D2) and middle finger(D3) in normal controls(68 hands) and CTS patients(95 hands) by bar electrode. The each mean NCV of both groups were compared to find the correlation between them. Results : The mean NCV of each median PPDN in control group were $38.7{\pm}4.2$(D1), $32.0{\pm}4.6$(D2), $34.2{\pm}4.4$(D3) m/sec, and in CTS group were $35.3{\pm}8.9$(D1), $20.2{\pm}5.2$(D2), $20.2{\pm}5.1$(D3) m/sec orderly. There were significant differences between mean NCV of each finger in control group(p=0.0001), but not between each left and right finger(p>0.05). The differences between each mean NCV of control and CTS were significant in all 3 fingers(p=0.0014, 0.0000, 0.0000). Conclusion : Bar electrode is a useful tool to evaluate the pathophysiologic state of the median PPDNs in normal controls and CTS patients.

  • PDF

Partial Discharge Characteristics of Ultra-High Voltage Cable Insulators by Needle Electrode (침 전극에 의한 초고압 케이블 절연재료의 부분방전 특성)

  • Kim, Gyun-Sig;Choi, Beom-Kyu;Byun, Doo-Gyoon;Cho, Kyung-Soon;Kim, Gwi-Yeol;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.477-480
    • /
    • 2004
  • In other to estimate an electrical properties of the cross linked polyethylene cable, the partial discharge properties due to charge of electrode shape(needle and bar) and void size were investigated at room temperature. Fast trip and breakdown time were appeared by the closed of needle electrode. The trip and breakdown voltage depend on insulator thickness. As the result, confirmed larger effect of void size than effect of insulator thickness. The effect of voids size than influence of insulation thickness was dominated by internal an electrode of inner insulators.

  • PDF

A Study on the Inflammable Gas Explosion Triggered by the Electric Discharge Static Eliminator on Voltage Application Type (전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구)

  • Lee Chun Ha;Ok Kyoung Jea;Kim Jum-Ho;Kwon Byung-Duck;Cha Ha-Na;Yun Kea Won
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.22-26
    • /
    • 2004
  • The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode.

Commercial Production for the Hydrogen Generation with Alkaline Electrode Cells (수소 생산을 위한 알칼라인 수전해장치 상용품 제작)

  • KIM, BO YEON;KIM, DONG JIN;KANG, EUN YOUNG;KIM, TAE WAN;SIM, HUI CHAN;LEE, TAECK HONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.3
    • /
    • pp.206-211
    • /
    • 2015
  • For the hydrogen production, Gas Lab and Gnc make alkaline watrer electrolyzer and found optimized condition of experimental parameters of cell material and operating procedures. For the commercial production, we saved electric power consumption and caloric based efficiency with over 70%. Used cell pressures are 10 bar, 30 bar and consumed electricity is $4,000A/m^2$, 4.19 kW ($T=100^{\circ}C$) at 10 bar. Another data is $2,000A/m^2$, 3.92 kW ($T=95^{\circ}C$) at 30 bar. Applied voltage is 1.75 V ($100^{\circ}C$, 10 bar), 1.64 V ($95^{\circ}C$, 10 bar), 1.81 V ($85^{\circ}C$, 30 bar), 1.76 V ($95^{\circ}C$, 30 bar). As cell temperature increase, applied voltage has been decreased and current has been increased. The concentration of KOH solution is 30 weight %.

Partial Discharge Characteristics of Ultra-High Voltage CV Cable Insulators by Electrode Shape (전극형상에 의한 초고압 CV케이블 절연체의 부분방전 특성)

  • Kim Gyun-Sig;Kim Byung-Hyun;Jeong Hyeon-Ki;Cha Kwang-Seok
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.712-717
    • /
    • 2005
  • In this thesis, it is investigated that the effect of the cross linked polyethylene(XLPE) insulator do to breakdown phenomenon by the insertion of the needle and bar electrode into XLPE which is used of electric power cable for the ultra-high voltage. The result of the partial discharge properties in the specimen showed that in case of the insertion of needle or bar electrode into XLPE, the effect of the inner discharge become large when the air void is bigger then the clearance of the electrode of the specimen. The closer the distance between the insulator and needle electrode, it takes less time to the insulation breakdown.

  • PDF

Performance of Membrane Electrode Assembly for DMFC Prepared by Bar-Coating Method (Bar-Coating 방법으로 제조한 직접메탄올 연료전지 MEA의 성능)

  • Kang, Se-Goo;Park, Young-Chul;Kim, Sang-Kyung;Lim, Seong-Yop;Jung, Doo-Hwan;Jang, Jae-Hyuk;Peck, Dong-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 2008
  • The key component of a direct methanol fuel cell (DMFC) is the membrane electrode assembly (MEA), which comprises a polymer electrolyte membrane and catalyst layers (anode and cathode electrode). Generally the catalyst layer is coated on the porous electrode supporter (e.g. carbon paper or cloth) using various coating methods such as brushing, decal transfer, spray coating and screen printing methods. However, these methods were disadvantageous in terms of the uniformity of catalyst layer thickness, catalyst loss, and coating time. In this work, we used bar-coating method which can prepare the catalyst layer with uniform thickness for MEA of DMFC. The surface and cross-section morphologies of the catalyst layers were observed by SEM. The performances and resistance of the MEAs were investigated through a single cell evaluation and impedance analyzer.

Effect of Cross-bar Length on Luminous Efficacy in AC-PDP with Fence Electrode Stricture

  • Nam, Hyung-Woo;Choi, Yong-Suk;Bae, Hyo-Won;Kim, Yun-Gi;Ok, Jung-Woo;Kim, Dong-Hyun;Lee, Ho-Jun;Lee, Hae-June;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.721-724
    • /
    • 2009
  • In this paper, we proposed fence electrode structures. The experimental structures change cross-bar length as 145, 105, 65 and $30{\mu}m$ to improve the electro-optical characteristics. The proposed structures improve the addressing time and luminous efficacy compared with the T145 structure which has the cross-bar length of $145{\mu}m$ as the reference. Especially, in the case of the T30 structure with cross-bar length of $30{\mu}m$, it gains lower power consumption by 34%, and higher luminous efficacy by 20% than those of the reference structure.

  • PDF