• Title/Summary/Keyword: Electrode area

검색결과 970건 처리시간 0.031초

Comparison between Two 450 mm Multi-Electrode Models

  • 박기정;이윤성;유대호;이진원;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.490-490
    • /
    • 2013
  • In semiconductor industry, it is expected that plasma process which use 450 mm source will be used at next generation. However, main obstacle of the large area plasma source is plasma uniformity from it. When electrode is enlarged, field difference between center area and side area reduces the plasma uniformity [1-3]. Therefore we investigate multi-electrode which diminish this field difference.We designed two multi-electrode models. One has two segments and the other has five segments. Each multi-electrode model is connected with two power generator and two matchers. One generator and one matcher is connected with center electrode part. The other one generator and the other one matcher is connected with side electrode part. The ion density is measured at 29 points by using floating harmonic method [4-6]. After measuring the data of each multi-electrode model, we discuss the difference of profile between two models' data.

  • PDF

인산형 연료전지 성능 특성에 미치는 전극 제조 조건의 영향 (Effects of electrode fabrication conditions on performance characteristics of phosphoric acid fuel cell)

  • 송락현;김창수;신동렬
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.224-229
    • /
    • 1996
  • Performance characteristics of single cell in phosphoric acid fuel cell were studied for various electrode fabrication parameters such as teflon content, electrode structure, thickness of electrocatalyst layer, platinum content and electrode area. The performance of single cell was decided from the measured voltage-current through a load change. The electrode of 40wt.% teflon exhibited high initial performance of single cell, but in the long term operation, the cell performance of 45 wt.% teflon was better. Also the single cell appeared good performance in case of electrodes with duplicate structure, thin electrocatalyst in thickness, more platinum content, and small area. These results of cell performance were discussed as related to the electrolyte flooding, formation of 3 phase boundary area, internal resistance of electrode, and microstructure of electrode.

  • PDF

전극의 3차원 측정데이터로부터 방전가공조건 결정 (Determination of Electrical Discharge Machining Parameters from the CMM data of a Electrode)

  • 주상윤
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.58-64
    • /
    • 2000
  • This paper proposes a method for determining optimal EDM parameters based on discharge area from the physical model of a tool electrode. Main parameters, which affect the EDM performance, are peak value of currents, pulse-on time, and pulse-off time. Such parameters are closely dependent on the discharge area in EDM process. In this paper the discharge area is estimated from the CMM scanning data to the tool electrode. The method is very useful when any geometric information to the tool electrode is not provided from tool modeler or producer. The method consists of following four steps. First a triangulation mesh is constructed from the CMM data. Secondly, the z-map is modeled from the triangulated mesh. Thirdly, the discharge area is estimated from intersection between the z-map model and a z-height plane. Finally, the machining parameters are easily calculated by some known EDM equations to the discharge area. An example is introduced to show that the machining parameters are calculated from the CMM data to a tool electrode.

  • PDF

음극 전극 표면적과 메틸렌블루 염색이 스펀지 탄소나노 튜브 전극 미생물 연료전지의 전력수율에 미치는 영향 (Effects of anode surface area and methylene blue dye treatment on the power density of microbial fuel cell with sponge and carbon nano tube electrode)

  • 이채영;박수희;송영채;우정희;유규선;정재우;한선기
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.883-888
    • /
    • 2012
  • Anode electrode is one of the most important factors in microbial fuel cell (MFC). This study was conducted to investigate the effects of mediator as methylene blue (MB) and electrode surface area on the power density of MFC with sponge and carbon nano tube (CNT) electrode (SC). The SC electrode with MB (MC) showed the maximum power density increased from 74.0 $mW/m^2$ to 143.1 $mW/m^2$. The grid shaped sponge and CNT (GSC) electrode showed the maximum power density of 209.2 $mW/m^2$ due to the increase of surface area from 88.0 to 152.0 $cm^2$. The GSC electrode with MB (GMC) revealed the maximum power density of 384.9 $mW/m^2$ which was 5.2 times higher than that obtained from the MFC with SC. Therefore MB and increase of surface area led to enhance the performance of microbial fuel cell such as power density.

New electrode structure for reducing power consumption of PDPs

  • Jung, Hae-Yoon;Cheong, Hee-Woon;Lee, Tae-Ho;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.69-72
    • /
    • 2008
  • A new electrode structure is proposed in this paper which can increase the discharge efficiency of plasma display panels and also decrease the panel capacitance by decreasing the electrode area effectively. Even with the decreased electrode area, the proposed structure could suppress the requirement for increasing the voltage and improve efficiency by limiting the discharge current.

  • PDF

광전극 두께와 표면적 변형에 따른 DSSC의 효율 특성 (DSSCs Efficiencies of Photo Electrode Thickness and Modified Photo Electrode Surface Area)

  • 권성열;양욱;주택원
    • 한국전기전자재료학회논문지
    • /
    • 제27권2호
    • /
    • pp.115-120
    • /
    • 2014
  • Photo electrode is an important component for DSSC. DSSCs electrical characteristics and efficiencies fabricated with different $TiO_2$ photo electrodes thickness and modified phoro electrode surface area were studied. $11{\mu}m$ $TiO_2$ photo electrode shows a 4.956% efficiency. The highest short circuit current density was a $9.949mA/cm^2$. Efficiencies and short circuit current density increased as tape casting thickness decreased. Modified surface area of the photo electrode by needle stamp processing were studied. 200 times needle stamp processing on photo electrodes shows a highest 5.168% efficiency. Also the short circuit current density was a $10.261mA/cm^2$.

Research on the Multi-electrode Plasma Discharge for the Large Area PECVD Processing

  • Lee, Yun-Seong;You, Dae-Ho;Seol, You-Bin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.478-478
    • /
    • 2012
  • Recently, there are many researches in order to increase the deposition rate (D/R) and improve film uniformity and quality in the deposition of microcrystalline silicon thin film. These two factors are the most important issues in the fabrication of the thin film solar cell, and for the purpose of that, several process conditions, including the large area electrode (more than 1.1 X 1.3 (m2)), higher pressure (1 ~ 10 (Torr)), and very high frequency regime (VHF, 40 ~ 100 (MHz)), have been needed. But, in the case of large-area capacitively coupled discharges (CCP) driven at frequencies higher than the usual RF (13.56 (MHz)) frequency, the standing wave and skin effects should be the critical problems for obtaining the good plasma uniformity, and the ion damage on the thin film layer due to the high voltage between the substrate and the bulk plasma might cause the defects which degrade the film quality. In this study, we will propose the new concept of the large-area multi-electrode (a new multi-electrode concept for the large-area plasma source), which consists of a series of electrodes and grounds arranged by turns. The experimental results with this new electrode showed the processing performances of high D/R (1 ~ 2 (nm/sec)), controllable crystallinity (~70% and controllable), and good uniformity (less than 10%) at the conditions of the relatively high frequency of 40 MHz in the large-area electrode of 280 X 540 mm2. And, we also observed the SEM images of the deposited thin film at the conditions of peeling, normal microcrystalline, and powder formation, and discussed the mechanisms of the crystal formation and voids generation in the film in order to try the enhancement of the film quality compared to the cases of normal VHF capacitive discharges. Also, we will discuss the relation between the processing parameters (including gap length between electrode and substrate, operating pressure) and the processing results (D/R and crystallinity) with the process condition map for ${\mu}c$-Si:H formation at a fixed input power and gas flow rate. Finally, we will discuss the potential of the multi-electrode of the 3.5G-class large-area plasma processing (650 X 550 (mm2) to the possibility of the expansion of the new electrode concept to 8G class large-area plasma processing and the additional issues in order to improve the process efficiency.

  • PDF

IN713LC-SCM440 이종재 마찰용접부의 부식특성에 미치는 pH의 영향 (The Effects of pH on the Corrosion Characteristics in Dissimilar Friction Welded Zone of IN713LC-SCM440)

  • 조상근;공유식;김영대
    • 한국해양공학회지
    • /
    • 제19권2호
    • /
    • pp.53-59
    • /
    • 2005
  • The effect of pH on the corrosion characteristics in the dissimilar friction welded zone of IN713LC-SCM440 in the loaded torsional stress was studied. The corrosion experiment was performed for 120 hours on the specimens with five steps of pH. The surface corrosion pattern of the SCM440 area showed global corrosion and narrow pitting, which was caused by galvanic corrosion between friction welded IN713LC and SCM440, but corrosion did not proceeded from the IN713LC area. The average relative electrode potential gradually tends to decrease with the elapse of the immersion time in the acidity area. The average corrosion current also gradually tend to decrease The corrosion rate showed a larger value when the average relative electrode potential was higher and the average relative current was lower. The corrosion rate showed a larger value when the average relative electrode potential was higher in the acidity area, and it showed large when the average relative electrode potential was lower in the alkalinity area.

경두개직류자극 시 전극 크기가 손기능에 미치는 영향 (The Effect of Electrode Size during tDCS on Hand Function)

  • 이혜진;박수지;권혜민;이정우
    • 대한임상전기생리학회지
    • /
    • 제10권2호
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose : This study is to examine the effect of electrode size during transcranial direct current stimulation on hand function. Methods : By randomly assigning 26 right hand dominant subjects to two groups (I: carbon rubber electrode / II: disposable circular self-adhesive electrodes) with 13 subjects in each group depending on the electrode size, a positive electrodeof transcranial direct current stimulation was placed on the primary motor area (C4) and a negative electrode was placed on the left primary motor area (C3) and the stimulation was applied for 20 minutes.Hand function assessment before and after transcranial direct current stimulation were measured with JTT (Jebsen-Taylor hand function test). Results : According to hand function assessment by JTT, there were no interactions on both hands, and statistically significant differences according to time appeared in the main effect test. Conclusion : Regardless of the electrode size, it appears that transcranial direct current stimulation on the primary motor area activated hand function affected.

침전극 저주파 자극이 흰쥐 중뇌수도주위 회색질의 nNOS 면역반응세포 변화에 미치는 영향 (The Effect of Needle Electrode Electrical Stimulation on the Change of neuronal Nitric Oxide Synthase Immunoreactive Cells in the periaqueductal area of the Rat)

  • 김수한;김지성;송치원
    • 대한물리치료과학회지
    • /
    • 제10권2호
    • /
    • pp.193-198
    • /
    • 2003
  • Acupuncture has been used as a clinical treatment in Oriental medicine for various diseases. In the present study was carried out to investigate the effects of acupuncture and electrical stimulation on the change neuronal nitric oxide synthase(nNOS) immunoreactive cells in the periaqueductal gray(PAG) area of the male SD rats. Enhanced expression of nNOS was detected in the dorsolateral-PAG(DL-PAG) area of rat with stress by fixed body, and acupuncture and needle electrode electrical stimulation groups at Hapgok like acupoint decreased the stress-induced enhancement in the expression of nNOS. The present results demonstrate that acupuncture and needle electrode electrical stimulation is effective in the modulation of expression of nNOS in the DL-PAG area under stress conditions.

  • PDF