• 제목/요약/키워드: Electrochemical migration

검색결과 65건 처리시간 0.024초

The Electrochemical Migration Phenomenon of the Ni-Cr Seed Layer of Sputtered FCCL

  • Ahn, Woo-Young;Jang, Joong Soon
    • 한국표면공학회지
    • /
    • 제47권2호
    • /
    • pp.63-67
    • /
    • 2014
  • As the demand for fine-pitch FPCB (Flexible Printed Circuit Board) increases, so do the number of applications of sputtered FCCL (Flexible Copper Clad Laminate). Furthermore, as the width between the circuit patterns decreases, greater defects are observed in the migration phenomenon. In this study we observed changes in ion migration in real circuit-pattern width using sputtered FCCL. We found that as the applied voltage and residue thickness of the NiCr seeds increase, ion migration occurs faster. If the NiCr seed layer thickens due to a high cathode power and long deposition time while being sputtered, the NiCr will form a residue that quickly becomes a factor for incurring ion migration.

Ion Migration in Metal Halide Perovskites

  • Nur'aini, Anafi;Lee, Seokwon;Oh, Ilwhan
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.71-77
    • /
    • 2022
  • Metal halide perovskites are promising photovoltaic materials, but they still have some issues that need to be solved. Hysteresis is a phenomenon that strongly is correlated with ion migration; thus, a fast, easy, and low-temperature method for measuring ion migration is required. Through selective blocking, ion migration can be measured separately, apart from electron migration. In this study, ion migration in metal halide perovskites was measured using a vertical device. At different temperatures, ionic activation energies were obtained for a range of perovskite compositions such as MAPbI3, FAPbI3, CsPbI3, and MAPbBr3. By comparing the measured ionic activation energies with the theoretical values, we conclude that among other possibilities, I- is the migrating ion in MAPbI3, FAPbI3, CsPbI3, and Br- is the migrating in MAPbBr3.

Sn-3.0Ag-0.5Cu, Sn-37Pb 표면처리 기판의 전기화학적 이온 마이그레이션 민감도 (Electrochemical Ion Migration Sensitivity of Printed Circuit Board Plated with Sn-3.0Ag-0.5Cu and Sn-37Pb)

  • 홍원식;박노창;오철민;김광배
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년 추계학술발표대회 개요집
    • /
    • pp.136-138
    • /
    • 2006
  • Recently a lots of problems have observed in high densified and high integrated electronic components. One of them is ion migration phenomena, which induce the electrical short of electrical circuit. Ion migration phenomena has been observed in the field of exposing the specific environment and using for a long time. Also as the RoHS restriction was started in July 1st, 2006, Pb-free solder was utilized in electronics assemblies. In this case, it is very important to compatible between components and printed circuit board(PCB), thus surface treatment materials of PCB was changed to Sn, Sn-3.0Ag-0.5Cu, Cu. Therefore these new application become to need to reevaluate the sensitivity about electrochemical ion migration. This study was evaluated the occurrence time of electrochemical ion migration using by water drop test. We utilized PCB(printed circuit board) having a comb pattern as follows 0.1, 0.318, 0.5, 1.0 mm pattern distance. Sn-3.0Ag-0.5Cu and Sn-37Pb were electroplated on the comb pattern. 6.5V and 15.0V were applied in the comb pattern and then we measured the electrical short time causing by occurring the ion migration. In these results, we evaluate the sensitivity and derived the prediction models of ion migration occurrence time depending on the pattern materials, applied voltage and pattern spacing of PCB conductor.

  • PDF

Difference of Potential Range Formed at the Anode Between Water Drop Test and Temperature Humidity Bias Test to Evaluate Electrochemical Migration of Solders for Printed Circuit Board

  • Young Ran Yoo;Young Sik Kim
    • Corrosion Science and Technology
    • /
    • 제22권3호
    • /
    • pp.153-163
    • /
    • 2023
  • Two types of accelerated tests, Water Drop Test (WDT) and Temperature-Humidity-Bias Test (THBT), can be used to evaluate the susceptibility to electrochemical migration (ECM). In the WDT, liquid water is directly applied to a specimen, typically a patterned conductor like a printed circuit board. Time to failure in the WDT typically ranges from several seconds to several minutes. On the other hand, the THBT is conducted under elevated temperature and humidity conditions, allowing for assessment of design and life cycle factors on ECM. THBT is widely recognized as a more suitable method for reliability testing than WDT. In both test methods, localized corrosion can be observed on the anode. Composition of dendrites formed during the WDT is similar to that formed during THBT. However, there is a lack of correlation between the time to failure obtained from WDT and that obtained from THBT. In this study, we investigated the relationship between electrochemical parameters and time to failure obtained from both WDT and THBT. Differences in time to failure can be attributed to actual anode potential obtained in the two tests.

유기 금속 할라이드 페로브스카이트에서 이온 이동 (Ion Migration in Organic Metal Halide Perovskites)

  • 오일환
    • 전기화학회지
    • /
    • 제21권2호
    • /
    • pp.21-27
    • /
    • 2018
  • 본 총설에서는 최근 전세계적으로 각광 받고 있는 유기 금속 할라이드 페로브스카이트 소재에서 일어나는 이온 이동 현상에 대한 최신 연구에 대해 정리하였다. 페로브스카이트 물질 조성, 인가전압에 따라 다른 결과들이 보고되었지만, 실제 태양전지 작동 조건에서 iodide 가 이동하는 것으로 보이며, 때로는 methylammonium의 이동도 관찰된다. 페로브스카이트는 상온에서 전자와 이온이 동시에 이동하는 이른바 mixed conductor이고, 이는 페로브스카이트 태양전지 전류-전압곡선의 hysteresis, 장시간 작동에 따른 성능 저하 등에 지대한 영향을 미친다.

콘크리트 중의 염화물 확산평가를 위한 전기화학적 촉진시험법 (Electrochemical Acceletated Test for Evaluation of Chloride Diffusion in Concrete)

  • 문한영;김홍삼;이승태;정호섭;최두선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.409-412
    • /
    • 2000
  • Many researchers have been trying to evaluate the diffusion coefficient of chloride ion in concrete by using qualitative and quantitative electro-migration tests. Up to now, however, there has been no sufficient method to closely determine the diffusion coefficient of chloride ion through electro-migration test. In this paper, the diffusion coefficient of chloride ion in concrete was investigated through an electro-migration test, that is, AASHTO T 277, Dhir's method, Tang's method and Andrade's method. And the results of these test were compared with each other.

  • PDF

Prediction of ions migration behavior in mortar under 2-D ALMT application to inhibit ASR

  • Liu, Chih-Chien;Kuo, Wen-Ten
    • Computers and Concrete
    • /
    • 제14권3호
    • /
    • pp.263-277
    • /
    • 2014
  • This study investigated four electric field configurations of two-dimensional accelerate lithium migration technique (ALMT), including line-to-line, plane-to-line, contour-to-line and plane-to-plane, and analyzed the ion migration behavior and efficiency. It was found that the free ion distribution diagram and voltage distribution diagram were similar, and ions migrated in the power line direction. The electrode modules were used for the mortar specimen with w/c ratio of 0.5. The effectively processed areas accounted for 14.1%, 39.0%, 49.4% and 51.4% of total area respectively on Day 28. Larger electrode area was more advantageous to ion migration. In addition, it was proved that the two-dimensional electric field could be divided into different equifield line active regions, and regarded as affected by one-dimensional electric field, and the ion migration results in various equifield line active regions were predicted by using the duration analysis method based on the theoretical model of ion migration obtained from one-dimensional test.

Equifield line simulation and ion migration prediction for concrete under 2-D electric field

  • Liu, Chih-Chien;Kuo, Wen-Ten;Huang, Chun-Yao
    • Computers and Concrete
    • /
    • 제12권4호
    • /
    • pp.431-442
    • /
    • 2013
  • This study attempted to find a proper method applicable to simulating practical equifield lines of two-dimensional Accelerate Lithium Migration Technique (ALMT), and evaluate the feasibility of using the theoretical ion migration model of one-dimensional ALMT to predict the ion migration behavior of two-dimensional ALMT. The result showed that the electrolyte or carbon plate can be used as matrix to draw equifield line graph similar to that by using mortar as matrix. Using electrolyte electrode module for simulation has advantages of simple production, easy measurement, rapidness, and economy. The electrolyte module can be used to simulate the equifield line distribution diagram in practical two-dimensional electrode configuration firstly. Then, several equifield line zones were marked, and several subzones under one-dimensional ALMT were separated from various equifield line zones. The theoretical free content distribution of alkali in concrete under two-dimensional electric field effect could be obtained from duration analysis.