• 제목/요약/키워드: Electrochemical immunoassay

검색결과 17건 처리시간 0.023초

An Electrochemical Enzyme Immunochip Based on Capacitance Measurement for the Detection of IgG

  • Yi, Seung-Jae;Choi, Ji-Hye;Kim, Hwa-Jung;Chang, Seung-Cheol;Park, Deog-Su;Kim, Kyung-Chun;Chang, Chulhun L.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권4호
    • /
    • pp.1298-1302
    • /
    • 2011
  • This study describes the development of an electrochemical array immunochip for the detection of IgG. Interdigitated immunochip platforms were fabricated by sputtering gold on a glass wafer by using MEMS process and then were coated with Eudragit S100, an enteric polymer, forming an insulating layer over the working area of immunochips. The breakdown of the polymer layer was exemplified by the catalytic action of urease which, in the presence of urea, caused an alkaline pH change. This subsequently caused an increase of the double layer capacitance of the underlying electrode. Used in conjunction with a competitive immunoassay format, this allowed the ratio of initial to final electrode capacitance to be directly linked with the concentration of analyte, i.e. IgG. Responses to IgG could be detected at IgG concentration as low as $250\;ngmL^{-1}$ and showed good linearity up to IgG concentration as high as $20\;{\mu}gmL^{-1}$.

Electrochemical Immunosensing of GOx-labeled CRP Antigen on Capture Antibody Monolayer Immobilized on Calixcrown-5 SAMs

  • Jung, Hye-Sook;Song, Kum-Soo;Kim, Tai-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권10호
    • /
    • pp.1792-1796
    • /
    • 2007
  • Insulating effects on Au electrode according to the thickness and density of coated materials are well-known. To do electrochemical immunoassay reproducibly the glod electrode would be coated with self-assembled monolayers and antobodies. To get reproducibility, the antobody monolayer should be packed at highest density so that the amount of immobilized antibody at defined area should be the same. The calix[4]crown-5 SAMs could provide the basis for the antibodies to be immobilized reproducibly and at highest density. But the insulating effect would be highest too. We proved that the compactly packed protein monolayers on SAMs inhibited the electron transfer by block the free shuttling of redox molecules. The inhibition was minimized by inserting redox molecules in between the proteins during immobilization process. In this paper, we demonstrated that the calix[4]crown-5 SAMs would provide the protein monolayers with highest density and new method to minimize the insulating effect by inserted redox molecules in between the compactly packed protein monolayers.

휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩 (One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System)

  • 박신욱;강태호;이준황;윤현철;양상식
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

Mass Spectrometry-Based Analytical Methods of Amatoxins in Biological Fluids to Monitor Amatoxin-Induced Mushroom Poisoning

  • Choi, Jin-Sung;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.95-105
    • /
    • 2022
  • Amatoxin-induced mushroom poisoning starts with nonspecific symptoms of toxicity but hepatic damage may follow, resulting in the rapid development of liver insufficiency and, ultimately, coma and death. Accurate detection of amatoxins, such as α-, β-, and γ-amanitin, within the first few hours after presentation is necessary to improve the therapeutic outcomes of patients. Therefore, analytical methods for the identification and quantification of α-, β-, and γ-amanitin in biological samples are necessary for clinical and forensic toxicology. This study presents a literature review of the analytical techniques available for amatoxin detection in biological matrices, and established an inventory of liquid chromatography (LC) techniques with mass spectrometry (MS), ultraviolet (UV) detection, and electrochemical detection (ECD). LC-MS methods using quadrupole tandem mass spectrometry, time-of-flight mass spectrometry, and orbitrap MS are powerful analytical techniques for the identification and determination of amatoxins in plasma, urine, serum, and tissue samples, with high sensitivity, specificity, and reproducibility compared to LC with UV and ECD, enzyme-linked immunoassay, and capillary electrophoresis methods.

Development of Disposable Immunosensors for Rapid Determination of Sildenafil and Vardenafil in Functional Foods

  • Vijayaraj, Kathiresan;Lee, Jun Hyuck;Kim, Hyung Sik;Chang, Seung-Cheol
    • 한국식품위생안전성학회지
    • /
    • 제32권2호
    • /
    • pp.83-88
    • /
    • 2017
  • 본 연구의 목적은 screen printed 탄소계 전극에 기반하여 기능성 식품중에 포함된 소량의 Sildenafil과 Vardenafil(SDF 및 VDF)을 쉽게 검출하기 위한 전류계 면역센서를 개발하고자 하였다. 본 연구에서 개발한 면역센서는 horseradish peroxidase로 labeling 시킨 후 비경쟁적 샌드위치 ELISA 측정법에 의한 원리를 이용하였다. 개발된 센서는 그래핀 산화물 및 키토산(ErGO-CS) 복합체를 단순한 전기화학적 증착에 의해 screen printed 탄소계 전극을 이용하는 원리이며, 감지된 화학물질을 평가하고 센서특성을 최적화하기 위해 전기 화학적 임피던스분광법, 순환 전압 전류법 등을 포함한 일련의 전기화학적 실험방법에 기초하여 완성되었다. 본 연구에서 개발된 센서는 100 pg/mL ~ 300 ng/mL 농도의 SDF 및 VDF에 대하여 직선상의 농도-의존적인 반응을 나타내었다. 또한 최저 검출 한계는 55 pg/mL이었으며, 센서의 민감도는 $1.02{\mu}Ang/mL/cm^2$로 산출되었다. 센서의 성능은 7.1%의 상대 표준편차로 매우 우수한 재현성을 나타내었다. 본 연구에서 개발된 센서의 전략적 가치는 향후 건강기능식품중에 함유된 SDF 및 VDF과 같은 의약품의 미량을 현장에서 쉽게 분석 할 수 있어서 비용-효과적 측면에서 그 가치가 우수하다는 것을 제시한다.

유체소자가 집적화된 면역검사용 휴대용 CMOS 바이오칩의 분석 (ANALYSIS OF FLUIDIC BEAD CUBE EMBEDDED PORTABLE CMOS SENSING SYSTEM FOR IMMUNO REACTION MONITORING)

  • 정용원;박세완;김진석;김현철;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.755-758
    • /
    • 2005
  • This paper describes the novel immunoassay sensing system for a portable clinical diagnosis system. It consists of a bead cage reactor and a CMOS integrated biosensor. It showed the simple and easy antibody coating method on beads by flow-through avidin biotin complex technology in a microfluidic device. It showed just 90 nL sample consumption and good result for the application of alpha feto protein. The bead cage reactor has the role of the antibody coating, antigen binding and enzyme linking for the electrochemical sensing method. The CMOS biosensor consists of ISFET (ion selective field effect transistor) biosensor and temperature sensor for detecting pH that is the byproduct of enzyme reaction. The sensitivity is 8 $kHz/^{\circ}C$ in a temperature sensor and 33 mV/pH in a pH sensor. After filling the 15 um polystyrene beads in bead cage, antibody flowed and reacted to beads. Subsequently, the biotinylated antigen flowed and bound to the antibody and GOD (glucose oxidase)-avidin conjugate flowed and reacted to the biotin of the biotinylated antigen. After this reaction process, glucose solution flowed and reacted to the GOD on beads. The hydrogen was generated by glucose-GOD reaction. And it was detected by the pH sensor.

  • PDF

폐암 질환 진단에 활용 가능한 바이오마커 검출용 바이오칩 센서 연구 동향 (Research Trend of Biochip Sensors for Biomarkers Specific to Diagnostics of Lung Cancer Diseases)

  • 이상혁;고은서;이혜진
    • 공업화학
    • /
    • 제29권6호
    • /
    • pp.645-651
    • /
    • 2018
  • 한국인의 암 사망률 1위를 차지하는 폐암은 발견되기 전까지 별다른 증상이 없어 환자는 병을 쉽게 인지하지 못하고, 기존의 진단법 또한 초기단계에는 적용이 어렵다. 해결책으로서, 분자수준에서의 체액분석을 폐암진단에 도입하는 방안이 제시되고 있다. 이를 위한 분석기기 가운데 대표적으로는 칩 기반 바이오센서가 있으며, 이 센서의 큰 장점으로는 고가의 분석장비나 숙련된 분석인력이 없이도 현장에서의 진단이 가능하다는 점이다. 본 미니총설에서는 폐암 진단에 활용가능한 혈액 내 바이오마커와 바이오칩 센서의 연구현황을 소개하고 이들의 발전가능성에 대해 논의하고자 한다.