• 제목/요약/키워드: Electrochemical compressor

검색결과 8건 처리시간 0.02초

전기화학적 수소 압축기의 열역학적 성능에 관한 연구 (Study on Thermodynamic Performance of Electrochemical Hydrogen Compressor)

  • 김태헌;김동윤;이동근;김영상;안국영;배용균;박진영;김영
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.141-148
    • /
    • 2023
  • The thermodynamic performance of the electrochemical hydrogen compressor was analyzed to perform a comparative analysis with the performance of the mechanical compressor. The performance was analyzed through the applied current and the measured voltage value. The test results showed that the efficiency of the electrochemical hydrogen compressor was high in the low current density range. In addition, it was confirmed that the amount of increasing compress work of the electrochemical hydrogen compressor is smaller than that of the mechanical compressor. Therefore, it is expected to have higher efficiency than mechanical compression when compressed with a sufficiently high-pressure range.

전기화학식 수소 압축기 직렬 스택 기술 (Series Stacking Techniques of Electrochemical Hydrogen Compressors)

  • 조상훈;김창종;김민수;김동규
    • 한국수소및신에너지학회논문집
    • /
    • 제35권2호
    • /
    • pp.168-174
    • /
    • 2024
  • The electrochemical hydrogen compressor was run under diverse operating conditions in order to probe its capabilities and limitations. It was found that, unlike single-cell operations, the electrochemical hydrogen compressor stack performance improved with a rise in temperature. This improvement in performance was attributed to the gradual weakening of the electro-osmotic drag over time, impacting membrane resistance. As a result of these experiments, compression levels, up to an impressive 120 bar, using the electrochemical hydrogen serial stack were achieved.

전기화학적 수소 압축기 기술 (A Review of Electrochemical Hydrogen Compressor Technology)

  • 김상경
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.578-586
    • /
    • 2020
  • There is growing interest worldwide in a hydrogen economy that uses hydrogen as an energy medium instead of hydrocarbon-based fossil fuels as a way to combat climate change. Since hydrogen has a very low energy density per unit volume at room temperature, hydrogen must be compressed and stored in order to use as an energy carrier. There are mechanical and non-mechanical methods for compressing hydrogen. The mechanical method has disadvantages such as high energy consumption, durability problems of moving parts, hydrogen contamination by lubricants, and noise. Among the non-mechanical compression methods, electrochemical compression consumes less energy and can compress hydrogen with high purity. In this paper, research trends are reviewed, focusing on research papers on electrochemical hydrogen compression technology, and future research directions are suggested.

$CO_2$ 환경하에서 접촉 표면에 적용한 마이크로 딤플 패턴이 마찰 및 마멸에 미치는 영향 연구 (Friction and Wear Characteristics of the Micro-dimple Surfaces in Rotary Compressor with Carbon Dioxide as Refrigerants)

  • 이영제;전홍규;한규철;최진호;김규만;조성욱
    • Tribology and Lubricants
    • /
    • 제24권6호
    • /
    • pp.374-377
    • /
    • 2008
  • Due to the environmental concerns, especially the greenhouse effect and GWP (Global Warming Potential), the carbon dioxide was investigated as an alternative natural refrigerant to replace HFCs (HydroFluoroCarbons) in refrigerator or air conditioning systems. Because new compressor with carbon dioxide is going to be operated under the high pressure, the tribology of sliding surfaces in the compressor becomes very important. To improve of wear resistance in compressor parts, especially rotary type, the friction and wear characteristics of improved sliding surfaces between vane and flange were evaluated in this paper. The method of reformed sliding surface, such as micro-dimple processes, was applied on surfaces in order to improve the tribological characteristics, and their performances were evaluated experimentally. The vane-on-flange type lubricated sliding tests were performed with a high pressure wear tester using carbon dioxide. Test results showed that the reformed surfaces were very effective to reduce the friction and the wear amounts of vane surfaces. The method of improved surfaces showed good tribological properties at vane and flange.

연료전지 자동차용 흡기 소음기의 설계 변수 최적화에 관한 연구 (Optimization of the Multi-chamber Perforated Muffler for the Air Processing Unit of the Fuel Cell Electric Vehicle)

  • 김의열;이상권
    • 한국소음진동공학회논문집
    • /
    • 제19권7호
    • /
    • pp.736-745
    • /
    • 2009
  • Fuel cells convert a fuel together with oxygen in a highly efficient electrochemical reaction to electricity and water. Since the electrochemical reaction in the fuel cell stack dose not generate any noise, Fuel cell systems are expected to operated much quieter than combustion engines. However, the tonal noise and the broad band noise caused by a centrifugal compressor and an electric motor cause which is required to feed the ambient air to the cathode of the fuel cell stack with high pressure. In this study, the multi-camber perforated muffler is used to reduce noise. We propose optimized muffler model using an axiomatic design method that optimizes the parameters of perforated muffler while keeping the volume of muffler minimized.

연료전지 자동차용 흡기 소음기의 설계 변수 최적화에 관한 연구 (Optimization of the multi-chamber perforated muffler for the air processing unit of the fuel cell electric vehicle)

  • 김의열;김민수;이상권;서상훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.342-350
    • /
    • 2009
  • Fuel cells convert a fuel together with oxygen in a highly efficient electrochemical reaction to electricity and water. Since the electrochemical reaction in the fuel cell stack dose not generate any noise, Fuel cell systems are expected to operated much quieter than combustion engines. However, the tonal noise and the broad band noise caused by a centrifugal compressor and an electric motor cause which is required to feed the ambient air to the cathode of the fuel cell stack with high pressure. In this study, the multi-camber perforated muffler is used to reduce noise. We propose optimized muffler model using an axiomatic design method that optimizes the parameters of perforated muffler while keeping the volume of muffler minimized.

  • PDF

수소와 질소 혼합 가스의 전기화학적 수소 분리에 관한 연구 (Study on Electrochemical Hydrogen Separation of Hydrogen and Nitrogen Mixture Gas)

  • 김동윤;김태헌;이동근;김영상;안국영;배용균;박진영;김영
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.149-154
    • /
    • 2023
  • In the Fourth Industrial Revolution, hydrogen energy is in the spotlight. There is a difficulty in commercialization due to the lack of hydrogen infrastructure. Therefore, a lot of hydrogen should be imported and a method using ammonia is the most useful. In this study, using the mixed gas of hydrogen and nitrogen generated when ammonia is decomposed, the hydrogen separation performance is to be tested. Hydrogen was separated using an electrochemical hydrogen compressor based on a fuel cell and the experiment was conducted by changing the ratio of hydrogen and nitrogen. In addition, the performance was also compared by the difference both the pressure and the membrane.

암모니아 활용 고체산화물 연료전지 재순환 발전 시스템 (Ammonia-fueled Solid Oxide Fuel Cell Recirculation Systems for Power Generation)

  • 박진영;쿠 엔;김진선;배용균;이동근;김영상;이선엽;김영
    • 한국수소및신에너지학회논문집
    • /
    • 제35권1호
    • /
    • pp.40-47
    • /
    • 2024
  • Ammonia is drawing attention as carbon free fuel due to its ease of storage and transportation compared to hydrogen. This study suggests ammonia fueled solid oxide fuel cell (SOFC) system with electrochemical hydrogen compressor (EHC)-based recirculation. Performance of electrochemical hydrogen pump is based on the experimental data under varying hydrogen and nitrogen concentration. As a result, the suggested system shows 62.04% net electrical efficiency. The efficiency is 10.33% point higher compared to simple standalone SOFC system (51.71%), but 0.02% point lower compared to blower-based recirculation system (62.06%). Further improvement in the EHC-based SOFC recirculation system can be achieved with EHC performance improvement.