• Title/Summary/Keyword: Electrochemical Corrosion Behavior

Search Result 304, Processing Time 0.02 seconds

Repassivation Behavior of Ni Base Alloys in a Mild Alkaline Water at 300℃

  • Hwang, Seong Sik;Kim, Dong Jin;Kim, Joung Soo;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.85-89
    • /
    • 2006
  • KAERI(Korea Atomic Energy Research Institute) has developed a repassivation rate test system which can be operated at $300^{\circ}C$. It consists of an autoclave, three electrodes for an electrochemical test and a diamond scratch tip. All the electrodes are electrically insulated from the autoclave by using high temperature fittings. Reproducible repassivation curves of alloy 600 at 300 C were obtained. Repassivation rate of alloy 600 at pH 13 was slower than that of pH 10. Stress corrosion cracking test was carried as a function of the pH at a high temperature. At pH 10, alloy 600 showed a severe stress corrosion cracking(SCC), whereas it did not show a SCC at pH 7. From the viewpoint of a relationship between the current density and the charge density, a big difference was observed in the two solutions; the slope of pH 13 was steeper than that of pH 10. So the stress corrosion susceptibility at pH 13 seems to be higher than that of pH 10. The system would be a good tool to evaluate the SCC susceptibility of alloy 600 at a high temperature.

Electrochemical corrosion study on base metals used in nuclear power plants in the HyBRID process for chemical decontamination

  • Kim, Sung-Wook;Park, Sang-Yoon;Roh, Chang-Hyun;Shim, Ji-Hyung;Kim, Sun-Byeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2329-2333
    • /
    • 2022
  • Base metal corrosion forms a significant issue during the chemical decontamination of the primary coolant loop in nuclear power plants as it is directly related to the economic and safety viability of decommissioning. In this technical note, potentiodynamic evaluations of several base metals (304 stainless steel, SA106 Grade B carbon steel, and alloy 600) were performed to determine their corrosion behavior during the hydrazine (N2H4)-based reductive ion decontamination (HyBRID) process. The results suggested that N2H4 protected the surface of the base metals in the HyBRID solution, which is primarily composed of H2SO4. The corrosion resistance of the carbon steel was further improved through the addition of CuSO4 to the solution. The corrosion rate of carbon steel in the H2SO4-N2H4-CuSO4 solution was lower than that exhibited in an oxalic acid solution, a commonly used reaction medium during commercial decontamination processes. These results indicate the superiority of the HyBRID process with respect to the base metal stability.

Effect of Phase Transformation Behavior of Electroless Nickel Plating Layer on Corrosion and Cavitation-Erosion with Heat Treatment (열처리에 따른 무전해 니켈 도금 층의 상변태 거동이 부식과 캐비테이션 침식에 미치는 영향)

  • Il-Cho Park;Seong-Jong Kim
    • Corrosion Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.64-71
    • /
    • 2024
  • The objective of this study was to investigate corrosion and cavitation-erosion characteristics of the electroless nickel plating layer with heat treatment. The crystallization temperature of the electroless nickel plating layer was about 410 ℃. The phase transformation energy was confirmed to be 12.66 J/g. With increasing heat treatment temperature, the amorphous electroless nickel plating layer gradually changed to crystalline Ni and Ni3P. At the same time, the crystal grain size was also increased. Additionally, when heat treatment was performed at a temperature above 400 ℃, NiO phase was observed due to oxidation phenomenon. As a result of the electrochemical polarization experiment, the corrosion resistance of the heat-treated electroless nickel plating layers was superior to that of the as-deposited plating layer. This was because crystal grains became larger and grain boundaries decreased during heat treatment. The cavitation-erosion resistance of heat-treated plating layers tended to be superior to that of as-deposited plating layers due to increased microhardness.

Electrochemical Behavior of Plasma Electrolytic Oxidized Films Formed in Solution Containing Mn, Mg and Si Ions

  • Lim, Sang-Gyu;Choe, Han Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.80-80
    • /
    • 2017
  • Titanium and its alloys that have a good biocompatibility, corrosion resistance, and mechanical properties such as hardness and wear resistance are widely used in dental and orthopedic implant applications. However, they do not form a chemical bond with bone tissue. Plasma electrolytic oxidation (PEO) that combines the high voltage spark and electro-chemical oxidation is a novel method to form ceramic coatings on light metals such as tita-nium and its alloys. This is an excellent re-producibility and economical, because the size and shape control of the nano-structure is relatively easy. Silicon (Si), manganese (Mn), and magne-sium (Mg) have a useful to bone. Particularly, Si has been found to be essential for normal bone, cartilage growth, and development. Mn influences regulation of bone remodeling be-cause its low content in body is connected with the rise of the concentration of calcium, phosphates and phosphatase out of cells. Pre-studies have shown that Mg plays very im-portant roles in essential for normal growth and metabolism of skeletal tissue in verte-brates and can be detected as minor constitu-ents in teeth and bone. In this study, Electrochemical behavior of plasma electrolytic oxidized films formed in solution containing Mn, Mg and Si ions were researched using various experimental in-struments. A series of Si-Mn-Mg coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 5 and 10%. The potentiodynamic polarization and AC impedance tests for corrosion behav-iors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV. Also, AC impedance was performed at frequencies anging from 10MHz to 100kHz for corrosion resistance.

  • PDF

A Study on the Flow-Accelerated Corrosion Characteristics of Galvanically Coupled Dissimilar Metals. (이종금속 연결에 따른 침부식(FAC) 특성에 관한 연구)

  • Kim, Jung-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.269-272
    • /
    • 2000
  • The flow accelerated galvanic corrosion characteristics of a carbon steel coupled to stainless steel were investigated in deaerated alkaline-chloride solutions as a function of flow velocities(0, 0.2, 0.4 and 0.6 m/s), pH(8, 9, and 10) and temperature(25, 50 and $75^{\circ}C$). The electrochemical properties of specimens were investigated by potentiodynamic test and galvanic corrosion test using RCE(Rotating Cylinder Electrode). Carbon steel did not show passive behavior in the alkaline-chloride solution. The galvanic current density increases with increasing flow velocity and temperature, but decreased with increasing pH. Flow velocity had a small effect on the galvanic current density at $25^{\circ}C$, whereas the flow velocity increased galvanic current density significantly at $50^{\circ}C$ and $75^{\circ}C$. This might be due to the increased solubility of magnetite at the higher temperature.

  • PDF

Corrosion characteristics of separator for MCFC (용융탄산염형 연료전지의 분리판 부식특성)

  • Kim, G.Y.;Eom, S.W.;Moon, S.I.;Moon, G.H.;Choi, Y.T.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1407-1408
    • /
    • 1996
  • The development of MCFC is going to the second stage of development and recent studies have been focusing on long-term durability of cell component. Systematic investigation on corrosion behavior of Fe-based alloys has been done in (62+38) mol % (Li+K) $CO_3$ melt at 923K by using steady-state polarization and electrochemical impedance spectroscopy method. It was found that the corrosion current t of these Fe-based alloys decreased with increasing Cr, Al content.

  • PDF

Beams affected by corrosion influence of reinforcement placement in the cracking

  • Ortega, Nestor F.;Rivas, Irene E.;Aveldano, Raquel R.;Peralta, Maria H.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.2
    • /
    • pp.163-175
    • /
    • 2011
  • The results of experimental and numerical investigations on reinforced concrete beams, with different longitudinal rebars affected by corrosive processes are presented in this paper. Different diameters and/or different distributions of longitudinal rebars were employed keeping constant the total section in each analyzed case, (maintaining a constant stirrup diameter and distribution). The rebars were subjected to accelerated corrosion in the experimental study. Electrochemical monitoring of the process, periodic measuring of the cover cracking and gravimetry of the rebars were performed through the test. Some building recommendations are obtained in order to be considered by designers of concrete structures. The numerical simulation was carried out through the application of the Finite Element Method (FEM), employing plane models, and using linear-elastic material model. The cracking process was associated with the evolution of the tensile stresses that were originated. This numerical methodology allows the monitoring of the mechanical behavior until the beginning of the cracking.

The Study on the Corrosion Characteristics of STS 304 Pipeline Steel Weldment for Gas Cooling & Heating System (가스 냉온수기용 STS 304 배관 용접부의 부식특성에 관한 연구)

  • Kim, Hwan-Sik;Lim, Uh-Joh
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.31-36
    • /
    • 2007
  • In order to study on the corrosion characteristics of STS 304 pipeline steel weldment for gas cooling & heating system. the electrochemical polarization test and corrosion test by impressed potential in 0.5M $H_2SO_4+0.01M$ KSCN solution was carried out. Also, SEM and hardness of welding zone was measured. And then passive behavior, corrosion behavior by the impressed potential and SEM aspect and hardness behavior of base metal(BM) and heat affected zone(HAZ) for STS 304 pipe were investigated. The main results are as follows: 1) The critical anodic current density of heat affected zone(HAZ) is drained more highly than that of base metal(BM), and primary passive potential of HAZ become higher than that of BM. 2) The passive current density of TUE is drained more highly than that of BM, and passive region of BM become bigger than that of HAZ. 3) By the impressed potential, the current density of HAZ is drained more than that of BM.

  • PDF

A Study on the Effect of Electrolyte Additives on Zn Electrode with Pb3O4 in Zn-AgO Secondary Battery System (Zn-AgO 이차 전지에서 Pb3O4가 첨가된 아연 전극에 미치는 전해질 첨가제의 영향에 관한 연구)

  • Park, Kyung-Wha;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.4
    • /
    • pp.242-249
    • /
    • 2003
  • Zn electrode was widely used as an anode material in alkaline battery systems in highly concentrated KOH electrolyte, however it was well known that its cycle life is significantly shortened by growth of dendrite due to the high dissolution of $Zn(OH)_2$ and rapid electrochemical reaction. In this study when by the additives such as $Ca(OH)_2$, Citrate, tartrate and Gluconate were added to $40\%$ KOH electrolyte at solution temperature of $25^{\circ}C$ and the amount of $5wt\%\;Pb_3O_4$ was mixed to Zn electrode and then the effect of $Pb_3O_4$ and additives on the electrochemical behavior of Zn electrode was investigated by Potentiodynamic Polarization Curves, Cyclic Voltammetry, Accelerated Life Cycle lest, and SEM image analyses. The addition of $Pb_3O_4$ reduced the corrosion rate of Zn electrode. The corrosion potential of Zn electrode with $Pb_3O_4$ was higher or lower than that of pure Zn electrode however was not influenced practically to the open circuit voltage. And the addition of 4 type additives had an important role in improving both cycle life in accelerated cycle life test and corrosion resistance. Furthermore the additive of Tartrate indicated comparatively a good effect to corrosion resistance as well as charging-discharging property Improvement among those four type additives.

An Overview on Hydrogen Uptake, Diffusion and Transport Behavior of Ferritic Steel, and Its Susceptibility to Hydrogen Degradation

  • Kim, Sung Jin;Kim, Kyoo Young
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.209-225
    • /
    • 2017
  • Development of high strength steel requires proper understanding of hydrogen behavior since the higher the steel strength the greater the susceptibility of hydrogen assisted cracking. This paper provides a brief but broad overview on hydrogen entry and transport behavior of high-strength ferritic steels. First of all, hydrogen absorption, diffusion and trapping mechanism of the steels are briefly introduced. Secondly, several experimental methods for analyzing the physical/chemical nature of hydrogen uptake and transport in the steels are reviewed. Among the methods, electrochemical permeation technique utilized widely for evaluating the hydrogen diffusion and trapping behavior in metals and alloys is mainly discussed. Moreover, a modified permeation technique accommodating the externally applied load and its application to a variety of steels are intensively explored. Indeed, successful utilization of the modified permeation technique equipped with a constant load testing device leads to significant academic progress on the hydrogen assisted cracking (HAC) phenomenon of the steels. In order to show how the external and/or residual stress affects mechanical instability of steel due to hydrogen ingress, the relationship among the microstructure, hydrogen permeation, and HAC susceptibility is briefly introduced.