• 제목/요약/키워드: Electrocatalytic oxidation

검색결과 80건 처리시간 0.021초

A Kinetic Investigation of Ethanol Oxidation on a Nickel Oxyhydroxide Electrode

  • Danaee, I.;Jafarian, M.;Sharafi, M.;Gobal, F.
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권1호
    • /
    • pp.50-56
    • /
    • 2012
  • Nickel modified NiOOH electrodes were used for the electrocatalytic oxidation of ethanol in alkaline solutions where the methods of cyclic voltammetry (CV) and chronoamperometry (CA) were employed. In CV studies, in the presence of ethanol, an increase in the current for the oxidation of nickel hydroxide is followed by a decrease in the corresponding cathodic current. This suggests that the oxidation of ethanol is being catalysed through mediated electron transfer across the nickel hydroxide layer comprising of nickel ions of various valence states. Under the CA regime the reaction followed a Cottrellian behavior and the diffusion coefficient of ethanol was found to be $1{\times}10^7cm^2s^{-1}$.

Pt-Ru@TiO2-H 나노구조체촉매의 합성 및 전기화학적 특성평가 (Electrocatalytic activity of the bimetallic Pt-Ru catalysts doped TiO2-hollow sphere nanocomposites)

  • 이인호;권해두;최성호
    • 분석과학
    • /
    • 제26권1호
    • /
    • pp.42-50
    • /
    • 2013
  • 이 논문은 센서 및 연료전지에 사용할 수 있는 $Pt-Ru@TiO_2-H$ 나노구조체촉매의 제조 및 전기화학적 촉매의 특성에 대한 것이다. 이 $Pt-Ru@TiO_2-H$ 나노구조체촉매는 주형제인 폴리스틸렌볼(PSB)을 제조하고, 이 주형제의 표면에 졸-겔 반응을 통해 $TiO_2$를 코팅한 후, $Pt^{4+}$$Ru^{3+}$의 환원에 의해 제조하였다. 제조된, $Pt-Ru@TiO_2-H$ 나노구조체촉매는 전자투과현미경(TEM), X-선 회절(XRD)와 원소분석에 의해 특성평가 하였고, $Pt-Ru@TiO_2-H$의 전기화학적 촉매특성은 에탄올, 메탄올, 도파민, 아스크로브 산, 프로말린과 글루코오즈의 산화-환원 능력에 의해 평가 하였다. 이 $Pt-Ru@TiO_2-H$ 나노구조체촉매는 바이오분자에 대해 전기화학적촉매 특성을 나타내어, 연료전지 전극 또는 비효소바이오센서에 사용 될 것으로 기대된다.

금속이 첨가된 탄소전극의 전기화학적 특성과 이를 이용한 L-lactate 바이오센서의 개발 (Electrocatalytic Properties of Metal-dispersed Carbon Paste Electrodes for Reagentless L-lactate Biosensors)

  • 윤현철;김학성
    • KSBB Journal
    • /
    • 제11권4호
    • /
    • pp.489-496
    • /
    • 1996
  • Carbon paste electrode를 채용함으로써 L-lac tate 측정용의 전기화학식 바이오센서를 성공적으로 개발할 수 있었다. 특히 뛰어난 electrocatalytic activity를 갖는 platinum이 첨가된 platinum-CPE 를 이용하여 낮은 전위에서의 NADH의 전기척 산 화가 가능하였다. Enzyme (lactate dehydrogen­a ase)과 $NAD^+$를 carbon paste형식으로 직접 제조 함으로써 L-lactate 측정을 위한 성공적인 바이요센 서의 개발이 가능하였다. 위와 같은 개발연구를 통 하여 다른 $NAD^+$ -dependent dehydrogenase를 채 용한 바이오센서로의 적용이 기대된다.

  • PDF

Facile Synthesis of Pt Nanoparticle and Graphene Composite Materials: Comparison of Electrocatalytic Activity with Analogous CNT Composite

  • Lee, Jihye;Jang, Ho Young;Jung, Insub;Yoon, Yeoheung;Jang, Hee-Jeong;Lee, Hyoyoung;Park, Sungho
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권7호
    • /
    • pp.1973-1978
    • /
    • 2014
  • Here, we present a facile method to synthesize Pt nanoparticles (NPs) and graphene composite materials (Pt/G) via vacuum filtration. Anodic aluminum oxide (AAO) templates were used to separate Pt/G composite and liquid phase. This method can be used to easily tune the mass ratio of Pt NPs and graphene. Pt NPs, graphene, and carbon nanotubes (CNTs) as building blocks were characterized by a variety of techniques such as scanning electron microscopy, UV-Vis spectroscopy, and Raman spectroscopy. We compared the electrocatalytic activities of Pt/G with Pt NP and CNT films (Pt/CNT) by cyclic voltammetry (CV), CO oxidation, and methanol oxidation. Pt/G was much more stable than pure Pt films. Also, Pt/G had better electrochemical activity, CO tolerance and methanol oxidation than Pt/CNT loaded with the same amount of Pt NPs due to the better dispersion of Pt NPs on graphene flakes without aggregation. We further synthesized Au@Pt disk/G and Pt nanorods/G to determine if our synthetic method can be applied to other NP shapes such as nanodisks and nanorods, for further electrocatalysis studies.

개미산 산화 반응을 위한 카본 담지 표면 합금의 전기촉매 활성 (Electrocatalytic activity of Carbon-supported near-surface alloys (NSAs) for Formic acid oxidation)

  • 박인수;최종호;이국승;전태열;성영은
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.459-462
    • /
    • 2006
  • Formic acid recently attracted attention as an alternative fuel for direct liquid fuel cells(DLFCs) due to its high theoretical open circuit voltage(1.45V). In this paper, a novel chemical strategy is described for the preparation and characterization of carbon-supported and surface-alloys, which were prepared by using a successive reduction process. After preparing Au colloid nanoparticles, the deposition of Au colloid nanoparticles occurred spontaneously in the carbon black-dispersed aqueous solution. Then nano-scaled Pt layer were formed on the surface of carbon-supported Au nanoparticles. The Au-Pt[x] showed the higher electrocatalytic activity than those of the particle-alloys and commercial one (Johnson-Matthey) for the reaction of formic acid oxidation when the mass-specific currents were compared. The increased electrocatalytic activity might be attributed to the effective surface structure of surface-alloys, which have a high utilization of active materials for the surface reaction of electrode.

  • PDF

Pyrocatechol Violet Modified Graphite Pencil Electrode for Flow Injection Amperometric Determination of Sulfide

  • Emir, Gamze;Karakaya, Serkan;Dilgin, Yusuf
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권3호
    • /
    • pp.248-256
    • /
    • 2020
  • In this study, pyrocatechol violet (Pcv) is proposed for the first time as an efficient electrocatalyst for oxidation of sulfide and flow injection analysis (FIA) of sulfide. A graphite pencil electrode (GPE) was modified with Pcv via immersion of the GPE into 0.01 M Pcv solution for 15 min. Cyclic voltammograms (CVs) demonstrated that Pcv/GPE exhibits a good electrocatalytic performance due to shift in the potential from +400 at bare GPE to +70 mV at Pcv/GPE and obtaining an enhancement in the peak current compared with the bare GPE. A linear range between 0.25 and 250 μM sulfide with a detection limit of 0.07 μM was obtained from the recorded current-time curves in Flow Injection Analysis (FIA) of sulfide. Sulfide in water samples was also successfully determined using the proposed FI amperometric methods.

SAMs of 2-Aminoethanethiol Modified with 3,4-Dihydroxyphenylalanine for the Electrocatalytic Oxidation of NADH on Gold Electrodes

  • Cha, Seong-Keuck
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.786-790
    • /
    • 2004
  • 2-Aminoethanethiol (aet) has been used to make self-assembled monolayer (SAMs) on gold electrodes, which are subsequently modified with 3,4-dihydroxy phenylalanine (dpa). Such modified electrodes having various types of Au/aet-dpa were employed in the electrocatalytic oxidation of NADH. The purpose of this study to characterize the responses of such modified electrodes in terms of the immobilization procedure, pH of the solution and applied potential. The reaction of the surface immobilized dpa with NADH was studied using the rotating disk electrode technique and a value of $2.2{\times}10^4M^{-1}s^{-1}$ was obtained for the second-order rate constant in 0.1 M Tris/$NO_3^-$buffer (pH=8.0). The hydration behavior of the films was characterized by quartz crystal microbalance. When used as a NADH sensor, the Au/aet-dpa electrode exhibited good sensitivity and an excellent correlation (r ${\geq}$ 0.99) for NADH concentration which extended to $3.8{\times}10^{-3}$ M.

Electro-Catalytic Behavior of an Antiarrhythmic Drug, Procainamide and its Electro-Analytical Applications

  • Abbar, Jyothi C.;Meti, Manjunath D.;Nandibewoor, Sharanappa T.
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권4호
    • /
    • pp.292-300
    • /
    • 2018
  • The electrocatalytic oxidative behavior of an antiarrhythmic drug, procainamide hydrochloride (PAH) at the gold electrode surface has been examined using different voltammetric methods like cyclic, linear-sweep and differential pulse voltammetry. Voltammograms obtained in this study reveal that the electrode exhibit excellent electrocatalytic activity towards oxidation of the drug. The parameters that can affect the peak current at different pH, scan rate and concentration were evaluated. The number of electrons transferred was calculated. The current displayed a wide linear response ranging from 0.5 to $30.0{\mu}M$ with a limit of detection of 56.4 nM. The impact of potential interfering agents was also studied. The electrode displayed wide advantages such as simple sample preparation, appreciable repeatability, reproducibility and also high sensitivity. Furthermore, the feasibility of the proposed method was successfully demonstrated by determining PAH in the spiked human biological sample.