• 제목/요약/키워드: Electrocardiograph

검색결과 46건 처리시간 0.024초

Optimal Selection of Wavelet Coefficients for Electrocardiograph Compression

  • Del Mar Elena, Maria;Quero, Jose Manuel;Borrego, Inmaculada
    • ETRI Journal
    • /
    • 제29권4호
    • /
    • pp.530-532
    • /
    • 2007
  • This paper presents a simple method to implement a complete on-line portable wireless holter including an electrocardiogram (ECG) monitoring, processing, and communication protocol. The proposed algorithm significantly reduces the hardware resources of threshold estimation for ECG compression, using the standard deviation updated with each new input signal sample. The new method achieves superior performance in terms of hardware complexity, channel occupation and memory requirements, while keeping the ECG quality at a clinically acceptable level.

  • PDF

심전도 및 맥파신호 기반의 감정인식 시스템에 관한 연구 (Research on the Emotion Recognition System based on Electrocardiograph and Pulse Signals)

  • 홍윤정;황윤경;신동규;김동현;신동일
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2008년도 춘계학술발표대회
    • /
    • pp.175-178
    • /
    • 2008
  • 본 논문은 생체 신호들 중 데이터 획득이 간편한 심전도와 맥파를 실시간으로 취득하여 기계학습 기법인 SVM (Support Vector Machine)알고리즘과 클러스터링 기법인 k-NN (Nearest Neighbor)알고리즘을 적용한 인간의 감정을 분석하는 시스템에 대한 연구결과를 제시한다.

Design of Kalman Filter to Estimate Heart Rate Variability from PPG Signal for Mobile Healthcare

  • Lee, Ju-Won
    • Journal of information and communication convergence engineering
    • /
    • 제8권2호
    • /
    • pp.201-204
    • /
    • 2010
  • In the mobile healthcare system, a very important vital sign in analyzing the status of user health is the HRV (heart rate variability). The used signals for measuring the HRV are electrocardiograph and PPG (photoplethysmograph). In extracting the HRV from the PPG signal, an important issue is that extract the exactly HRV from PPG signal distorted from the user's movements. This study suggested a design method of the Kalman filter to solve the problem, and evaluated the performances of a proposed method by PPG signals containing motion artifacts. In the results of experiments that compared with a variable step size adaptive filter proposed in recently, the proposed method showed better performance than an adaptive filter.

도로주행 중 휴대전화 수신시 핸드폰 형태와 대화난이도에 따른 심전도 변화 (Heart Rate Variability on Telephone types and IOD of Conversation while Driving)

  • 이경태;장필식;김기현;임정빈;이동현
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2005년도 춘계공동학술대회 발표논문
    • /
    • pp.554-559
    • /
    • 2005
  • It seems to be dangerous to use a cellular phone while driving since it increases driver's mental stress and makes driver's reaction time slow. This study is to investigate driver's psycho-physiological responses on mobile telephoning while driving. Among the three experimental factors (mobile-phone types, message IODs over mobile-phone, road types), only the message IODs over mobile-phone changed R-R intervals of electrocardiograph significantly. This result suggests that the regulations on the mobile telephoning while driving be changed.

  • PDF

Enhancement of Blood Compatibility of Albumin-Immobilized Polyurethane

  • Gyu Ha Ryu;Don
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권4호
    • /
    • pp.269-274
    • /
    • 1992
  • In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.raph.

  • PDF

R-to-R Extraction and Preprocessing Procedure for an Automated Diagnosis of Various Diseases from ECG Data

  • Timothy, Vincentius;Prihatmanto, Ary Setijadi;Rhee, Kyung-Hyune
    • Journal of Multimedia Information System
    • /
    • 제3권2호
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, we propose a method to automatically diagnose various diseases. The input data consists of electrocardiograph (ECG) recordings. We extract R-to-R interval (RRI) signals from ECG recordings, which are preprocessed to remove trends and ectopic beats, and to keep the signal stationary. After that, we perform some prospective analysis to extract time-domain parameters, frequency-domain parameters, and nonlinear parameters of the signal. Those parameters are unique for each disease and can be used as the statistical symptoms for each disease. Then, we perform feature selection to improve the performance of the diagnosis classifier. We utilize the selected features to diagnose various diseases using machine learning. We subsequently measure the performance of the machine learning classifier to make sure that it will not misdiagnose the diseases. The first two steps, which are R-to-R extraction and preprocessing, have been successfully implemented with satisfactory results.

ECG-NIBP-$SpO_2$ 환자감시장치 개발 (Development of ECS-NIBP-$SpO_2$ Patient Monitoring System)

  • 김남현;심원흠;이건기;라상원;김경하
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

Pulmonic stenosis with atrial septal defect in a Siamese cat

  • Kim, Ji-Youn;Lee, Sung-Wook;Lee, Seung-Gon;Suh, Sang-Il;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제57권1호
    • /
    • pp.63-66
    • /
    • 2017
  • A 6-month-old mature intact female Siamese cat presented with exertional dyspnea. Diagnostic studies revealed pleural effusion, grade 4/6 left basal systolic murmur, deep S-wave in electrocardiograph leads I, II, and III, cardiomegaly with pleural effusion on radiography, pulmonic systolic (~5.8 m/sec) and tricuspid (3.6 m/sec) regurgitant jets, atrial septal defect, and a hypoplastic right outflow tract. Based on these results, the case was diagnosed as pulmonic stenosis with atrial septal defect. To the best of our knowledge, this is the first case report describing pulmonic stenosis with atrial septal defect in a cat in Korea.

모듈형 환자 모니터의 개발 (Development of a Module-Based Bedside Monitor for Patient Monitoring)

  • 우응제;박승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.133-146
    • /
    • 1997
  • In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases, each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO with plethysmograph.raph.

  • PDF

A 10-Lead Long Duration Ambulatory ECG Design -Minimizing power consumption-

  • Kim, Eung-Kyeu;Lee, Hoon-Kyeu
    • 융합신호처리학회논문지
    • /
    • 제16권1호
    • /
    • pp.29-34
    • /
    • 2015
  • The ECG(Electrocardiograph) ambulatory test as called Holter is performed usually to diagnose several heart diseases causing different arrhythmias. This paper exposes the insights of the design of a 10-lead ambulatory ECG recorder. Reducing the size and minimizing the power consumption of the ECG recorder are crucial to allow long recording time without causing discomfort to the patient. This paper proposes lower hardware design and differential compression algorithm to extend the maximum 72 hours recording time in consideration of smaller and light-weighted recorder size. The performance results by newly introduced compression algorithm are shown and discussed.