• Title/Summary/Keyword: Electro magnetic

Search Result 1,044, Processing Time 0.026 seconds

A Study on Surface Tension Measurement for the Water through Electro-Magnetic Field (전자장을 통과한 물의 표면장력 측정에 대한 연구)

  • 고영하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.826-831
    • /
    • 2003
  • The purpose of this study was to measure the surface tension of hard water through electro-magnetic field for investigating the effect of electro-magnetic water treatment. The maximum reduction of surface tension was 8% comparing to the no treatment case. When the flow velocity through the permanent magnetic device (PMD) was 6.3 m/s, sample of hard water had the minimum surface tension.

A study on physical characteristics by temperature changes of electro-magnetic clutch installed in electric point machine (전기전철기용 전자클러치의 온도 변화에 따른 물리적 특성에 대한 연구)

  • Shim Jae-Bock;Ohn Jung-Guen;Kwon Ki Jin;Choi Yeng-Ha
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1259-1265
    • /
    • 2004
  • Electro-magnetic clutch which is affected by elements of electric, magnetic and mechanical friction is important that it has a characteristic changes by environmental impact. Expecially, it is equipped in railroad sideway which is bleak external environment. Therefore, this paper investigated affections by temperature changes, which can make out through physical characteristics such as friction torque, minimum slipping torque, rated slipping torque of electro-magnetic dutch.

  • PDF

Quality Evaluation of Pork with Various Freezing and Thawing Methods

  • Ku, Su Kyung;Jeong, Ji Yun;Park, Jong Dae;Jeon, Ki Hong;Kim, Eun Mi;Kim, Young Boong
    • Food Science of Animal Resources
    • /
    • v.34 no.5
    • /
    • pp.597-603
    • /
    • 2014
  • In this study, the physicochemical and sensory quality characteristics due to the influence of various thawing methods on electro-magnetic and air blast frozen pork were examined. The packaged pork samples, which were frozen by air blast freezing at $-45^{\circ}C$ or electro-magnetic freezing at $-55^{\circ}C$, were thawed using 4 different methods: refrigeration ($4{\pm}1^{\circ}C$), room temperature (RT, $25^{\circ}C$), cold water ($15^{\circ}C$), and microwave (2450 MHz). Analyses were carried out to determine the drip and cooking loss, water holding capacity (WHC), moisture content and sensory evaluation. Frozen pork thawed in a microwave indicated relatively less thawing loss (0.63-1.24%) than the other thawing methods (0.68-1.38%). The cooking loss after electro-magnetic freezing indicated 37.4% by microwave thawing, compared with 32.9% by refrigeration, 36.5% by RT, and 37.2% by cold water in ham. The thawing of samples frozen by electro-magnetic freezing showed no significant differences between the methods used, while the moisture content was higher in belly thawed by microwave (62.0%) after electro-magnetic freezing than refrigeration (54.8%), RT (61.3%), and cold water (61.1%). The highest overall acceptability was shown for microwave thawing after electro-magnetic freezing but there were no significant differences compared to that of the other samples.

Changes in Ultrastructure and Sensory Characteristics on Electro-magnetic and Air Blast Freezing of Beef during Frozen Storage

  • Choi, Yun-Sang;Ku, Su-Kyung;Jeong, Ji-Yun;Jeon, Ki-Hong;Kim, Young-Boong
    • Food Science of Animal Resources
    • /
    • v.35 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • The ultrastructure in the beef muscle of the electro-magnetic resonance and air blast freezing during the frozen storage, and the changes in the quality characteristics after thawing were evaluated. The size of ice crystal was small and evenly formed in the initial freezing period, and it showed that the size was increased as the storage period was elapsed (p<0.05). The beef stored by the electro-magnetic resonance freezing showed the size of ice crystal with a lower rate of increase than the air blast freezing during the frozen storage. The thawing loss of beef stored by the electro-magnetic resonance freezing was significantly lower than the air blast freezing during frozen storage (p<0.05), and it showed that the thawing loss of the round was higher than the loin. Water holding capacity decreased as the storage period became longer while the electro-magnetic resonance freezing was higher than the air blast on 8 month (p<0.05). As a result of sensory evaluation, the beef stored by the electro-magnetic resonance freezing did not show the difference until 4 months, and it showed higher acceptability in comparison with the beef stored by the air blast freezing. Thus, it is considered that the freezing method has an effect on the change in the ultrastructure and quality characteristics of the beef.

A Study on the Applicability of High Manganese Steel to Naval Ship Hulls (고망간강의 함정 선체 적용 가능성에 관한 연구)

  • Kwangho Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.1
    • /
    • pp.61-67
    • /
    • 2024
  • A naval mine is an effective weapon system implemented for defending defends ports and seas. A mine is an underwater weapon that poses a great threat to ships sailing over the sea from shallow areas. Most of the influence-type naval mines detect magnetic field signals from ships and determine the final time of fire. Therefore, the level of underwater electro-magnetic signatures of ships is a key requirement for determining the survival of ships in wartime situations where mines are emplaced. The main reason why the high manganese steel is attracting attention for naval ship hulls is its nature as a non-magnetic steel. The non-magnetic hull does not generate electro-magnetic signatures; thus, it has the advantage improving the stealth of the ship. In this paper, I examine whether this material can be applied in the hulls material of naval ships that must be ableto reduce underwater electro-magnetic signatures by considering the non-magnetic characteristics of the first developed high manganese steel in the world.

Experimental Study on the chuncking Pressure Distribution of Electro-Magnetic Chucks (전자척의 고정압력분포에 관한 실험적 연구)

  • 김청균
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.1
    • /
    • pp.27-32
    • /
    • 1996
  • This paper deals with the distributions of magnetic flux of an electro-magnetic chuck which is one of the most commonly used chucking attachments in a surface grinding machine. The measured results showed good correspondence with the theoretical results which were previously presented by the same author. The normal and tangential components of the magnetic flux density were measured using the gauss meter. The measured results indicated that the magnetic flux density was periodically changing over the transverse position to the magnetic pole. The normal component of magnetic flux decreases very rapidly for the increased z position.

  • PDF

Theoretical Analysis of Magnetic Flux Density Distribution in an Electro-Magnetic Chuck

  • Kim, Chung-Kyun
    • KSTLE International Journal
    • /
    • v.2 no.2
    • /
    • pp.114-119
    • /
    • 2001
  • The distribution of magnetic flux density of electro-magnetic chucks may clarify the clamping characteristics, which is strongly related to the machining efficiency and machining accuracy in surface grinding machine. Therefore the distribution of the normal and the tangential components of magnetic flux density have been analyzed theoretically. It appears that the normal component of magnetic flux density increases and the tangential component of magnetic flux density increases as the ratio of the separator width to the pitch, e/p decreases. The results seem to increase the stability and uniformity of normal component of magnetic flux density for the decreased e/p.

  • PDF

Magnetic Characteristic of Square Electro-Magnetic Chuck using for Grinding Machine (연삭기용 직각 전자척의 자력특성에 관한 연구)

  • 맹희영;이용구
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.215-222
    • /
    • 2003
  • The new square electro-magnetic chuck, which is using for the clamping devices on a grinding machine, is developed in this study to improve the convenience of grinding works. The various kinds of structures are recommended to find the most adequate magnetic characteristics through the analytical approach using finite element methods. The analyzed results are retrofitted to solve the drawbacks of previous models step by step by considering the magnetic fields, strength and distribution of drag force, and thermal deformations of chuck. such as high parallelism and flatness. Finally the best recommended models is designed to satisfy the KS specifications required for the commercial magnetic chuck. The prototype chuck with this dimensions and structures is manufactured. For this final model, the experimental verifications are investigated whether the KS specifications are satisfied.

  • PDF

Magnetic Charateristics of Square Electro-Magnetic Chuck for Grinding Machine (연삭기용 직각 전자척의 자력특성에 관한 연구)

  • Maeng Hee-young;Kim SungHwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.8-15
    • /
    • 2005
  • The new square electro-magnetic chuck, which can be used for the clamping devices on a grinding machine, is developed in this study to improve the convenience of grinding works. The various kinds of structures are recommended to find the most adequate magnetic characteristics through the analytical approach using finite element methods. The analyzed results are retrofitted to solve the drawbacks of previous models step by step by considering the magnetic fields, strength and distribution of drag force, and thermal deformations of chuck such as high parallelism and flatness. Finally the best recommended models is designed to satisfy the KS specifications required fur the commercial magnetic chuck. The prototype chuck with this dimensions and structures is manufactured. For this final model, the experimental verifications are investigated whether the KS specifications are satisfied.