• Title/Summary/Keyword: Electro interstitial scan

Search Result 3, Processing Time 0.018 seconds

Evaluation of Clinical Usefulness of EIS(Electro Interstitial Scan) (EIS(Electro Interstitial Scan) 방법의 임상적 유효성 연구)

  • Kim, Soochan;Bae, Jang-Han;Jun, Min-Ho;Kim, Jaeuk U.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.124-133
    • /
    • 2015
  • Electro interstitial scan shows potential as a non-invasive screening method. It can discriminate some diseases based on electric current response to induce low intensity direct current to limbs or local area of body. DDFAO was invented in France and it is claimed that multi-channel EIS(Electro Interstitial Scan) is useful for various diseases, especially, diagnoses of endocrine system such as diabetics are very effective. In this study, we verified the repeatability and sensitivity of DDFAO by using a RC phantom model and its clinical usefulness using data obtained from normal and diabetes subject groups. As a result, it showed the repeatability and the output change according to change of phantom characteristic, but it was hard to distinguish normal and patient groups non-invasively with just six surface electrodes of DDFAO. The repeatability and the clinical accuracy was not sufficient for screening or diagnostic purposes, as well. In spite of the results with low repeatability and accuracy conducted in this study, we still need further investigations to improve the EIS-based measurement method; EIS is very convenient and simple and it shows potential as a screening tool of the whole body health conditions rather than localized disease diagnosis.

Diagnosis of Diabetes Using Voltage Analysis Based on EIS (Electro Interstitial Scan) (EIS 기반 전압신호 분석을 통한 당뇨병 진단 가능성 평가)

  • Bae, Jang-Han;Kim, Soochan;Kaewkannate, Kanitthika;Jun, Min-Ho;Kim, Jaeuk U.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.114-122
    • /
    • 2016
  • EIS (Electro interstitial scan) is a non-invasive and simple method to find the physio-pathological information inferred by electric current response with respect to low direct current applied between remote sites of the body. Although a few EIS-based devices for diagnosing diabetes were commercialized, they were not successful in offering clinical validity nor in confirming diagnostic principle. In this study, we measured the voltage responses of diabetic patients and normal subjects with a commercialized EIS device to test the usefulness of EIS in screening diabetes. For this purpose, voltage was measured between pairs of electrodes contacted at both palm, both soles of the feet and left and right forehead above both eyes. After feature extraction of voltage signals, the AUC (area under the curve) between the two groups was calculated and we found that seven variables were appropriately shown above 60% of accuracy. In addition, we applied the k-NN (k-nearest neighbors) method and found that the accuracy of classification between the two groups reached the accuracy of 76.2%. This result implies that the voltage response analysis based on EIS has potential as a diabetics screening method.

Mild stimulation of stomach 36 acupuncture point by organic nanoscale SP6 patch improves cellular physiologic functional status of different organs

  • Nazeran, Homer;Blake-Greenberg, Sherry;Haltiwanger, Emily
    • CELLMED
    • /
    • v.2 no.1
    • /
    • pp.10.1-10.6
    • /
    • 2012
  • Acupuncture works by stimulating peripheral sensory nerves and their endings causing an increase in cutaneous blood flow and microcirculation, as well as release of neurotransmitters, neuropeptides, and hormones. SP6 Patch is a nanoscale nontransdermal device that mildly stimulates Stomach 36 (zusanli) and other acupuncture points. As stimulation of these points has been indicated to have an effect on hypothalamic function, it is of great research interest to investigate the effect of SP6 Patch on the physiology of organs that are affected by hypothalamic regulation. Bioelectrical tissue impedance data indicative of cellular physiologic organ function, using an Electro Interstitial Scan (EIS) system, were acquired from hypothalamus, pancreas, liver, intestines, kidneys, thyroid and adrenal glands in 10 (1 male, 9 females) volunteers while wearing the SP6 Patch daily for 1 week. EIS testing was performed at baseline with no patch, 30 min after wearing the patch, and after wearing the patch 12 h/day for 1 week. Subjects were instructed to keep well hydrated during the study period. All subjects served as their own control. The hypothesis was: The SP6 Patch worn 12 h/day on the Stomach 36 acupuncture point for 1 week, may significantly improve cellular physiologic functional status of different organs measured by EIS. All tested organs achieved significant improvement in their functional physiologic status after wearing the SP6 Pach 12 h/day for 1 week compared to baseline with an overall average statistical power > 89%. Based upon these results the hypothesis was accepted as true.