• 제목/요약/키워드: Electricity production

검색결과 460건 처리시간 0.029초

Electrochemical Regeneration of FAD by Catalytic Electrode Without Electron Mediator and Biochemical Reducing Power

  • JEON SUNG JIN;SHIN IN HO;SANG BYUNG IN;PARK DOO HYUN
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.281-286
    • /
    • 2005
  • We created a new graphite-Cu(II) electrode and found that the electrode could catalyze FADH$_2$ oxidation and FAD reduction coupled to electricity production and consumption, respectively. In a fuel cell with graphite-Cu(II) anode and graphite-Fe(III) cathode, the electricity was produced by coupling to the spontaneous oxidation of FADH$_2$ Fumarate and xylose were not produced from the enzymatic oxidation of succinate and xylitol without FAD, respectively, but produced with FAD. The production of fumarate and xylose in the reactor with FAD electrochemically regenerated was maximally 2- 5 times higher than that in the reactor with FAD. By using this new electrode with catalytic function, a bioelectrocatalysts can be engineered; namely, oxidoreductase (e.g., lactate dehydrogenase) and FAD can function for biotransformation without an electron mediator and second oxidoreductase for cofactors recycling.

Analysis on the EU Energy Market Trends and Policies

  • Kim Eun-Sun;Koo Young-Duk;Park Young-Seo
    • Journal of information and communication convergence engineering
    • /
    • 제3권2호
    • /
    • pp.63-66
    • /
    • 2005
  • In 2000, the EU set up an energy policy related renewables use for electricity demand up to $22\%$ on the purpose of preventing energy exhaustion and world climate exchange. Technology development and energy production policy on coal, oil and natural gas focus on how to minimize their environmental effects since the world energy system will continue to be dominated by fossil fuels with almost $90\%$ of total energy supply in 2030. In the long run, the EU drives expansion policy of the renewable energy. If related policies and programs will show successful operation in the near future and will be resulted in increase of budget, we could expect the possibility of expansion of renewable energy market in Korea in the future.

An Analysis of the Environmental Benefits of the Price Signal Recovery under the Current Electricity Tariff in Korea (국내 계약종별 전기요금 체계의 가격신호 회복에 따른 환경편익 분석)

  • Jae Yeob Kim;Yeonjei Jung
    • Environmental and Resource Economics Review
    • /
    • 제31권4호
    • /
    • pp.909-930
    • /
    • 2022
  • Although the electricity tariff for each customer class in Korea has an institutional basis which can be linked to cost fluctuations caused by the increase in fuel cost, there is a situation in which it cannot be raised in a timely manner, considering the national economic burden such as inflation. There can be some disagreements about unconditionally raising electricity rates when cost increases occur. It is, however, well known that Korean domestic electricity rates are very low around the world and are in an environment in which rates are not easily adjusted. Moreover, as Korean electricity rates cannot be easily raised due to various factors, domestic electricity rates for each customer class itself have not delivered a desirable price signal for power consumption. Based on historical data such as fuel costs and power production by power source from 2017 to 2020, this study estimated how much power consumption would change if electricity rates were adjusted in 2030 and price signal distortion was resolved. As a result of the estimation, power consumption will be reduced by 9,000 GWh if the current electricity bill is adjusted to a level which can be 100% recovered even with the supply cost alone. This led to a reduction of about 3.82 million CO2tons of greenhouse gas emissions in the Korean power sector.

Electricity Generation Using Cyanobacteria Synechocystis PCC 6803 in Photosynthetic Bio-Electrochemical Fuel Cell (남조류 Synechocystis PCC 6803을 이용한 생물전기화학적 물분해 전기 생산)

  • Kim, Min-Jin;Oh, You-Kwan;Kim, Mi-Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제19권6호
    • /
    • pp.529-536
    • /
    • 2008
  • Cyanobacteria Synechocystis PCC 6803 or the extracted thylakoid membrane from this strain was appled to photosynthetic bio-electrochemical fuel cell(PBEFC) for the production of hydrogen under the illumination of 48Klux using halogen lamp. PBEFC was composed of anode, cathode and membrane between them. Electrode material was carbon paper while electron mediator and receptor were added phenazine methosulfate(PMS) and potassium ferricyanide respectively. When water and 50 mM tricine buffer and $300{\mu}M$ PMS were added to the anode under the light condition, PBEFC produced the current density $4.4{\times}10^{-5}\;mA/cm^2$, $1.4{\times}10^{-4}\;mA/cm^2$ and $2.4{\times}10^{-4}\;mA/cm^2$, respectively. And the addition of the thylakoid membrane to the system increased current density to $1.3{\times}10^{-3}\;mA/cm^2$. Two times increase of the thylakoid membrane into the anode doubled the current density to $2.6{\times}10^{-3}\;mA/cm^2$. But the current density was not increased proportionally to the amount of thylakoid membrane increased. The system was unstable to measure the electricity output due to the foam production in the anode. Addition of triton X-100 and tween 80 stabilized the system to measure the electricity output but the current density was not increased higher than $8.4{\times}10^{-4}\;mA/cm^2$ and $2.3{\times}10^{-3}\;mA/cm^2$. When the thylakoid membrane was substituted to Synechocystis PCC 6803 cells of four-day culture which has chlorophyll contents $20.5{\mu}g/m{\ell}$, maximum current density was $1.3{\times}10^{-3}\;mA/cm^2$ with $1\;k{\Omega}$ resistance.

A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building (차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구)

  • Park, Se-Hyeon;Kang, Jun-Gu;Bang, Ah-Young;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • 제35권2호
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

Optimal response of process type customer under the electricity spot pricing (시 변화 요금제 하의 공정형 수용가의 최적 전력 사용)

  • Son, K.M.;Hong, J.H.;Choi, J.Y.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.197-201
    • /
    • 1990
  • Under the electricity spot pricing, a customer can maximize its profit by adjusting its production schedule. This paper discusses the optimal response of process type customer to the spot pricing. A fast optimization algorithm is proposed. A case study reveals the potential benefits of customer under the electricity spot pricing.

  • PDF

Calculation for Components of Locational Marginal Price considering Demand-Side Bidding in a Competitive Electricity Market (경쟁시장내의 수요자원입찰을 고려한 모선별 한계가격의 구성요소산정 기법)

  • Kim, Hyun-Houng;Kim, Jin-Ho;Park, Jong-Bae;Shin, Joong-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제57권7호
    • /
    • pp.1157-1166
    • /
    • 2008
  • This paper presents a new approach for the evaluation of location marginal prices (LMPs) considering demand-side bidding (DSB) in a competitive electricity market. The stabilization of the electric power supply and demand balance is one of the major important activities in electric power industry. In this paper, we present an analytical method for calculation of LMPs considering DSB, which has opportunity to compete with generating units, as England & Wales Pool's DSB scheme[1]. Also, we propose a new approach that LMP considering DSB is divided into three components. The proposed approach can be used for the evaluation of demand-side bidding into the electricity market and the assessment of the influence of DSB on total production costs and LMPs as well as three components.

Strategy Equilibrium in Stackelberg Model with Transmission Congestion in Electricity Market

  • Lee, Kwang-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.90-97
    • /
    • 2014
  • Nash Cournot Equilibrium (NCE) has been widely used in a competitive electricity market to analyze generation firms' strategic production quantities. Congestion on a transmission network may lead to a mixed strategy NCE. Mixed strategy is complicated to understand, difficult to compute, and hard to implement in practical market. However, Stackelberg model based equilibrium does not have any mixed strategy, even under congestion in a transmission line. A guide to understanding mixed strategy equilibrium is given by analyzing a cycling phenomenon in the players' best choices. This paper connects the concept of leader-follower in Stackelberg model with relations between generation firms on both sides of the congested line. From the viewpoint of social welfare, the surplus analysis is presented for comparison between the NCE and the Stackelberg equilibrium (SE).

Development of Korean Market Simulator (한국형 Market Simulator 개발)

  • Hur, Jin;Kang, Dong-Joo;Kook, Kyung-Soo;Kim, Tai-Hyun;Lee, Jeong-Ho;Moon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.108-110
    • /
    • 2002
  • Power System deregulation has become a worldwide trend which introduces competition in electric power system in order to realize efficient electricity production and investment. In this regard, it is very important to develop an electricity market simulator so that it is to analyze power market and study bidding strategies, market operation and market power and train market participants. In this paper, we introduce general functions and a structure of market simulator, also design the framework of the Korean market simulator based on core concepts of electricity market simulator.

  • PDF

Development of ultra high frequency Surgery machine using LCC Inverter (LCC인버터를 이용한 초고주파 수술기 개발)

  • Kim, Sang-Hyo;Lee, Joon-Tark;Lee, Oh-Keol
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2328-2330
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current.

  • PDF