• Title/Summary/Keyword: Electricity IT

Search Result 1,877, Processing Time 0.03 seconds

Optimal Capacity Determination of Hydrogen Fuel Cell Technology Based Trigeneration System And Prediction of Semi-closed Greenhouse Dynamic Energy Loads Using Building Energy Simulation (건물 에너지 시뮬레이션을 이용한 반밀폐형 온실의 동적 에너지 부하 예측 및 수소연료전지 3중 열병합 시스템 적정 용량 산정)

  • Seung-Hun Lee;Rack-Woo Kim;Chan-Min Kim;Hee-Woong Seok;Sungwook Yoon
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.181-189
    • /
    • 2023
  • Hydrogen has gained attention as an environmentally friendly energy source among various renewable options, however, its application in agriculture remains limited. This study aims to apply the hydrogen fuel cell triple heat-combining system, originally not designed for greenhouses, to greenhouses in order to save energy and reduce greenhouse gas emissions. This system can produce heating, cooling, and electricity from hydrogen while recovering waste heat. To implement a hydrogen fuel cell triple heat-combining system in a greenhouse, it is crucial to evaluate the greenhouse's heating and cooling load. Accurate analysis of these loads requires considering factors such as greenhouse configuration, existing heating and cooling systems, and specific crop types being cultivated. Consequently, this study aimed to estimate the cooling and heating load using building energy simulation (BES). This study collected and analyzed meteorological data from 2012 to 2021 for semi-enclosed greenhouses cultivating tomatoes in Jeonju City. The covering material and framework were modeled based on the greenhouse design, and crop energy and soil energy were taken into account. To verify the effectiveness of the building energy simulation, we conducted analyses with and without crops, as well as static and dynamic energy analyses. Furthermore, we calculated the average maximum heating capacity of 449,578 kJ·h-1 and the average cooling capacity of 431,187 kJ·h-1 from the monthly maximum cooling and heating load analyses.

Construction and Operation of Small Solar Plant Using Smart-Off-Grid: Case of Tanzania-Korea Innovative Technology and Energy Center (스마트-독립전력망을 사용한 소규모 태양광 발전소의 건설과 운영: 한국-탄자니아 적정기술 거점센터의 사례)

  • Kim, Jisoo;Jung, Woo-Kyun;Ha, Bo-Ra;Moon, Ji-Hyun;Rhee, Herb;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.5 no.2
    • /
    • pp.62-69
    • /
    • 2019
  • Supplying stable electric power is one of the important objectives of the Official Development Assistance (ODA) because it is strongly related with improving living standards and income levels in the region. However, rural areas in many developing countries are not properly connected to national power grids, and even areas connected to national power grids are frequently blacked out due to limitations in power capacity. These lack of electric power is a major obstacle to improving income levels and improving living standards in those areas. The Korea-Tanzania Innovative and Energy Center (iTEC), which was established by Seoul National University in cooperation with the Nelson-Mandela Africa Institute of Science and Technology and Technology (NM-AIST) try to build a small solar power plant using a smart-off grid in rural area of Tanzania, where there is no electricity. 10 kW and 7 kW solar power plants are built in Mkalama Village in Kilimanajaro Region and Ngurdoto Village in Arusha Region to provide power to about 50 households each. In addition, smart monitoring systems were installed to collect data about status of power system and power consumption of each house. iTEC seeks for sustainable improvement the income level and quality of life of rural residents in developing countries through the construction of small solar power plants using smart-off grid, and the implementation of various connected projects.

Scenario Analysis, Technology Assessment, and Policy Review for Achieving Carbon Neutrality in the Energy Sector (에너지 부문의 탄소중립 달성을 위한 국내외 시나리오 분석 및 기술, 정책현황 고찰)

  • Han Saem Park;Jae Won An;Ha Eun Lee;Hyun Jun Park;Seung Seok Oh;Jester Lih Jie Ling;See Hoon Lee
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.496-504
    • /
    • 2023
  • Countries worldwide are striving to find new sources of sustainable energy without carbon emission due to the increasing impact of global warming. With the advancement of the fourth industrial revolution on a global scale, there has been a substantial rise in energy demand. Simultaneously, there is a growing emphasis on utilizing energy sources with minimal or zero carbon content to ensure a stable power supply while reducing greenhouse gas emissions. In this comprehensive overview, a comparative analysis of carbon reduction policies of government was conducted. Based on international carbon neutrality scenarios and the presence of remaining thermal power generation, it can be categorized into two types: "Rapid" and "Safety". For the domestic scenario, the projected power demand and current greenhouse gas emissions in alignment with "The 10th Basic Plan for Electricity Supply and Demand" was examined. Considering all these factors, an overview of the current status of carbon neutrality technologies by focusing on the energy sector, encompassing transitions, hydrogen, transportation and carbon capture, utilization, and storage (CCUS) was offered followed by summarization of key technological trends and government-driven policies. Furthermore, the central aspects of the domestic carbon reduction strategy were proposed by taking account of current mega trends in the energy sector which are highlighted in international scenario analyses.

Application of LCA on Lettuce Cropping System by Bottom-up Methodology in Protected Cultivation (시설상추 농가를 대상으로 하는 bottom-up 방식 LCA 방법론의 농업적 적용)

  • Ryu, Jong-Hee;Kim, Kye-Hoon;Kim, Gun-Yeob;So, Kyu-Ho;Kang, Kee-Kyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1195-1206
    • /
    • 2011
  • This study was conducted to apply LCA (Life cycle assessment) methodology to lettuce (Lactuca sativa L.) production systems in Namyang-ju as a case study. Five lettuce growing farms with three different farming systems (two farms with organic farming system, one farm with a system without agricultural chemicals and two farms with conventional farming system) were selected at Namyangju city of Gyeonggi-province in Korea. The input data for LCA were collected by interviewing with the farmers. The system boundary was set at a cropping season without heating and cooling system for reducing uncertainties in data collection and calculation. Sensitivity analysis was carried out to find out the effect of type and amount of fertilizer and energy use on GHG (Greenhouse Gas) emission. The results of establishing GTG (Gate-to-Gate) inventory revealed that the quantity of fertilizer and energy input had the largest value in producing 1 kg lettuce, the amount of pesticide input the smallest. The amount of electricity input was the largest in all farms except farm 1 which purchased seedlings from outside. The quantity of direct field emission of $CO_2$, $CH_4$ and $N_2O$ from farm 1 to farm 5 were 6.79E-03 (farm 1), 8.10E-03 (farm 2), 1.82E-02 (farm 3), 7.51E-02 (farm 4) and 1.61E-02 (farm 5) kg $kg^{-1}$ lettuce, respectively. According to the result of LCI analysis focused on GHG, it was observed that $CO_2$ emission was 2.92E-01 (farm 1), 3.76E-01 (farm 2), 4.11E-01 (farm 3), 9.40E-01 (farm 4) and $5.37E-01kg\;CO_2\;kg^{-1}\;lettuce$ (farm 5), respectively. Carbon dioxide contribute to the most GHG emission. Carbon dioxide was mainly emitted in the process of energy production, which occupied 67~91% of $CO_2$ emission from every production process from 5 farms. Due to higher proportion of $CO_2$ emission from production of compound fertilizer in conventional crop system, conventional crop system had lower proportion of $CO_2$ emission from energy production than organic crop system did. With increasing inorganic fertilizer input, the process of lettuce cultivation covered higher proportion in $N_2O$ emission. Therefore, farms 1 and 2 covered 87% of total $N_2O$ emission; and farm 3 covered 64%. The carbon footprints from farm 1 to farm 5 were 3.40E-01 (farm 1), 4.31E-01 (farm 2), 5.32E-01 (farm 3), 1.08E+00 (farm 4) and 6.14E-01 (farm 5) kg $CO_2$-eq. $kg^{-1}$ lettuce, respectively. Results of sensitivity analysis revealed the soybean meal was the most sensitive among 4 types of fertilizer. The value of compound fertilizer was the least sensitive among every fertilizer imput. Electricity showed the largest sensitivity on $CO_2$ emission. However, the value of $N_2O$ variation was almost zero.

A Study on the Indoor-Outdoor $NO_2$ Levels and Personal Exposures to $NO_2$ with Analysis of factors Affecting the $NO_2$ Concentrations - Centering on Urban Homes and Housewives - (실내외 $NO_2$농도 및 $NO_2$개인폭로량과 이들에 영향을 미치는 요인에 관한 연구 -도시지역 주택 및 주부를 대상으로-)

  • Chun, Jin-Ho;Lee, Chae-Un;Kim, Joon-Youn;Chung, Yo-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.132-151
    • /
    • 1988
  • This study was conducted to establish the control program for preventing unfavorable health effects of nitrogen dioxide($NO_2$) exposure in homes by preparing the fundamental data for evaluation of relation-ships between $NO_2$ levels and influencing factors through measurements of indoor-outdoor $NO_2$ levels and personal $NO_2$ exposures for housewives with questionnaire survey on 172 homes in Pusan area from April to June, 1987 $NO_2$ measurements were made by using diffusion tube samplers(Palmes tube $NO_2$ sampler) for one week at 4 sites in homes ; kitchen(KIT), bedroom(BED), living room(LIV), outdoor(OUT) and near the collar of housewives(personal exposure livel, PNO). The details of questionnaire were number of household members(FAM), number of regular smokers (SMOKER), daily number of meals eaten(MEAL), type of housing units(HOUSE), location of house with distance from the heavy traffic roads as walking time(DIST), and of kitchen(KAREA), kind of cooking fuels(FUEL), cooking time of each meal(CTIME), usage of kitchen fan for cooking(FAN), type of heating facilities(HEAT) and so on of subject homes. The Obtained results were as fellows : 1) The mean $NO_2$ level was significantly higher at indoors than outdoors(p<0.01) and the kitchen $NO_2$ level was the highest with $33.7{\pm}13.6ppb$(9.5-81.5ppb). The mean personal exposure level of $NO_2$ for housewives was $20.6{\pm}8.8ppb$(3.1-46.9ppb). 2) The mean indoor $NO_2$ level was significantly higher in the group of household members above 5 than below 4(p<0.05), in detached dwellings than apartments(p<0.001), within 5 minutes of distance than over 5 minutes(p<0.001), in the group of unusing fan(p<0.001), in the group of longer cooking time(p<0.001), and it was in order of coal briquette, gas, electricity and oil by kind of cooking fuels(p<0.05). 3) Variables showing significant correlation(p<0.001) with indoor $NO_2$ level were kitchen $NO_2$ level(r=0.8677), cooking time(r=0.5921), outdoor $NO_2$ level(r=0.5192), personal $NO_2$ exposure level(r=0.4615), usage of kitchen fan(r=0.3573) and location of house(r=-0.2988) 4) As a result of multiple regression analysis, the most significant influencing variable to the kitchen $NO_2$ level was cooking time[KIT=$-0.378{\pm}11.772$(CTIME)+0.298(OUT)+3.102(FAN)], it was kitchen $NO_2$ level to the indoor $NO_2$ level[IND=6.996+0.458(KIT)+0.230(OUT)-1.127(KAREA)], and it was indoor $NO_2$ level to the personal $NO_2$ exposure level[PNO=15.562+0.729(IND)-4.542(DIST)-0.200(KIT)] 5) It was recognized that aritificial ventilation in the kitchen, suppression of unnecessary combustion and replacement of cooking fuel, as much as possible, were effective means for decreasing indoor $NO_2$ levels in homes.

  • PDF

A Study of material analysis and its experimentation of metamorphosis and its utilities in Copper Alloy plates for contemporary metal craft (현대금속공예용 동합금판의 재료분석과 형질변환 실험 및 응용에 관한 연구)

  • Lim, Ock-Soo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.241-250
    • /
    • 2004
  • In this research, the copper alloy plates C2200, C5210, C7701, C8113 were selected to make datum and to identify further usage of metal craft experimentation. For its experimentation, the general welding and TIG welding methods were researched; for 2nd experimentation, the Reticulation and Electroforming skill's differences in color and temperature were researched. With these methods 3 different kinds of works are introduced for sample studies. For this research, Dr. Lee, Dong-Woo who works in Poongsan Metal Co, supported 4 kinds of copper alloy metals. Which are Commercial bronze (Cu-Zn), Deoxidiged Copper(Cu-Sn-P), Nickel Silver (Cu-Ni-Zn), and White Bronze (Cu-Ni); they were applied partly and wholly by the method of Laminatin, Reticulation, Fusing, and Electroforming skills. In case of C2200, the brass, the A. C. TIG welding method is better under 2mm slight plate; the D.C. TIG welding is better upper 2mm plate; and 250~300$^{\circ}C$ is recommended for remain heat treatment. In case of C5210, not having Hydrogen in high temperature return period, doesn't need Oxygen in high temperature and hardening in comparative high temperature neither, it is good for welding. It contains Sn 2-9% ad P 0.03-0.4% generally; and in accordance with the growth rate of Sn contain amount, the harden temperature boundary become broad. In case of cold moment after welding, they are recommended that higher speed TIG welding, smaller melting site and less than 200$^{\circ}C$ for pre-heating temperature. In case of C7701, the 10-20% Ni, 15-30% Zn are widely used.. If it is upper 30% Zn, it become (${\alpha}+{\beta}$) system and adhesive power rate become lower, and the productivity become lower in low temperature but the productivity become higher in high temperature. Nickel Silver's resistance of electricity is well; and the heatproof and incorrodibility is good, too. Lastly, in case of C8113, good at persistence in salty and grind; high in strength of high temperature. In case of white brass, contain 10-30% Nickel and hardened in high temperature and become single phrase. For these reason, the crystallization particles easily become large, if the resistance become higher small amount of Pb, P, S separation rate become higher.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

A Study on the Improvement of User Value through the Analysis of the Status of Smart Home Service in Korea Based on the Internet of Things (사물인터넷 기반 국내 스마트 홈서비스 현황 및 사용 후기 분석을 통한 사용자 가치 제고방안에 관한 연구)

  • Yoon, Seong-Jeong;Kim, Min-Yong
    • Management & Information Systems Review
    • /
    • v.36 no.5
    • /
    • pp.45-60
    • /
    • 2017
  • This study aims to elucidate the key improvements through the current state of customer support for smart home services based on the Internet of things and the evaluation of user's usage. Smart home services typically provide a wide range of value in terms of security, safety, manageability (electricity and water use), convenience, and remote management accessibility. In this study, we analyzed the current state of smart home service based on Internet of Samsung, SKT and LG U + companies in Korea. However, since LG U+ is the only company providing user reviews, there is a limit to generalization, but we are trying to figure out whether the customer value is conveyed properly or not, and in which part the customer support is focused to support the service. As a result of analyzing the results of the study, we found that the smart home service is commercialized and marketed in various forms. However, it is questionable whether the technological level and user satisfaction level are sufficiently satisfied. The results of this study are as follows. First, although each company provides usage guidance, they still ask many questions about joining products and using products. Second, there are many defects in the product itself, and it is found that the companies are not satisfied with the overall response. Third, the three companies are focusing on switches, outlets, sensors, and lamps. This is an individual intelligent product rather than an interlocking or linking level, and it can be seen that there are many parts that are not compatible with the concept of the original Internet of things. In conclusion, this study shows that there are still many areas to improve on the level of customer service provision of smart home service, in particular, the ease of use is low and the quality of products is not reliable. We would like to present the improvement of this in detail through this study and reflect the companies that provide it and the service providers.

Feasibility Study on the Fault Tree Analysis Approach for the Management of the Faults in Running PCR Analysis (PCR 과정의 오류 관리를 위한 Fault Tree Analysis 적용에 관한 시범적 연구)

  • Lim, Ji-Su;Park, Ae-Ri;Lee, Seung-Ju;Hong, Kwang-Won
    • Applied Biological Chemistry
    • /
    • v.50 no.4
    • /
    • pp.245-252
    • /
    • 2007
  • FTA (fault tree analysis), an analytical method for system failure management, was employed in the management of faults in running PCR analysis. PCR is executed through several processes, in which the process of PCR machine operation was selected for the analysis by FTA. The reason for choosing the simplest process in the PCR analysis was to adopt it as a first trial to test a feasibility of the FTA approach. First, fault events-top event, intermediate event, basic events-were identified by survey on expert knowledge of PCR. Then those events were correlated deductively to build a fault tree in hierarchical structure. The fault tree was evaluated qualitatively and quantitatively, yielding minimal cut sets, structural importance, common cause vulnerability, simulation of probability of occurrence of top event, cut set importance, item importance and sensitivity. The top event was 'errors in the step of PCR machine operation in running PCR analysis'. The major intermediate events were 'failures in instrument' and 'errors in actions in experiment'. The basic events were four events, one event and one event based on human errors, instrument failure and energy source failure, respectively. Those events were combined with Boolean logic gates-AND or OR, constructing a fault tree. In the qualitative evaluation of the tree, the basic events-'errors in preparing the reaction mixture', 'errors in setting temperature and time of PCR machine', 'failure of electrical power during running PCR machine', 'errors in selecting adequate PCR machine'-proved the most critical in the occurrence of the fault of the top event. In the quantitative evaluation, the list of the critical events were not the same as that from the qualitative evaluation. It was because the probability value of PCR machine failure, not on the list above though, increased with used time, and the probability of the events of electricity failure and defective of PCR machine were given zero due to rare likelihood of the events in general. It was concluded that this feasibility study is worth being a means to introduce the novel technique, FTA, to the management of faults in running PCR analysis.

Effects of an Improved Side Vent on Yield of Oriental Melon and Temperature in Single-span Plastic Greenhouse with Roof Ventilation Fans (지붕 환기팬이 설치된 단동 플라스틱 온실에서 개선된 측창형태가 하우스 내 온도 및 참외 수량에 미치는 영향)

  • Yu, In Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Shin, Young An
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.283-290
    • /
    • 2017
  • In this study, the method to attach plastic film on the side vent from inside of greenhouse for the entire length was developed as the way to make crops less stressful while uniformly getting outside air into the greenhouse when ventilating using roof ventilation fans at single-span plastic greenhouse for oriental melon in a low-temperature period. The plastic film was installed from ground to 10cm below from the height where side vent is fully opened. In order to verify that the improved side vent can improve greenhouse environment and fruit yield, it was compared with the control plot of conventional side vent. Both greenhouses were not ventilated until February 25th, 2017. Air temperature in both greenhouses exceeded $40^{\circ}C$ in mid February. Therefore, it is judged that the greenhouse should be ventilated from mid February. Air temperature in the control plot exceeded $30^{\circ}C$ from late April. Therefore, it is judged that the plastic film attached to the inside of side vent should be removed in late April, or in early May at the latest. Soil temperature in the treatment plot in the mid Aril exceeded $20^{\circ}C$, which is suitable for growth, while that in the control plot was still below $20^{\circ}C$. Soil temperature in the control plot finally exceeded $20^{\circ}C$ in late April. The consumption of electricity was 47.2 kWh in the treatment plot, and 48.3 kWh in the control plot, which was no significant difference. The marketable yield of oriental melon in the treatment plot was 5,094kg, which was 23.9% more than that in the control plot, 4,113kg. The marketable fruit ratio was 73.5% in the treatment plot, and that in the control plot was 73.9%, which was no significant difference.