• Title/Summary/Keyword: Electrical strength

Search Result 2,277, Processing Time 0.024 seconds

Mechanical Strength Properties of Hanger Insulator for Arrestor (피뢰기 절연행거의 기계적 강도 특성)

  • 박기호;조한구;한동희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.589-592
    • /
    • 2001
  • Generally, hanger insulator for polymer arrestor have to be good insulation properties and mechanical strength and weatherability, But many remark and repairs have been to think about low cost and light weight. The Paper is used Polymer arrestor for post and performance analysis and mechanical strength insulator hanger according to development of simplest product. To enhance the efficiency of experimental modal analysis, we proposed the process which is the selection of the locations and the number of measurement points for pre-test.

  • PDF

A Study on the Dielectric Strength of Composite Materials(I) (복합재료의 전기적 절연특성과 개발에 관한 연구(I))

  • 정은식;강창남;박정후
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.8
    • /
    • pp.323-330
    • /
    • 1985
  • Dielectric loss tangent and ac dielectric strength of GFRP (Glass Fiber Reinforced Plastics, G-10)was investigated as parameters of mechanical and thermal stresses, in order to study the basic dielectrical characteristics of composite insulating materials. The dielectric loss tangent was increased and the ac dielectric strength was decreased with increase in the mechanical stresses beyond the mechanical yield point on account of fiber-matrix debonding, but the dielectric constant was not varied sigificantly. the dielectric strength of G-10 was about 2 MV/cm and the dielectric constant was about 4.8.

  • PDF

Development of High Strength and Low Loss Overhead Conductor(I) - Mechanical Properties (고강도 저손실 가공송전선의 개발(I) - 기계적 특성)

  • Kim, Byung-Geol;Kim, Shang-Shu;Park, Joo-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1152-1158
    • /
    • 2005
  • New conductor is developed by using high strength nonmagnetic steel(NM) wire as the core of overhead conductor. This conductor is called ACNR overhead conductor(Aluminum Conductor Nonmagnetic Steel Reinforced). Formed by the combination of aluminum alloy wire and high strength nonmagnetic steel wire, it has about the same weight and diameter as conventional ACSR overhead conductor. To enhance properties beneficial in an electrical and mechanical conductor during the process of high strength nonmagnetic steel wire, we made a large number of improvements and modifications in the working process, aluminum cladded method, and other process. ACNR overhead conductor, we successfully developed, has mechanical and electrical properties as good as or even better than conventional galvanized wire. Microstructure of raw material M wire was austenite and then deformed martensite after drawing process. Strength at room temperature is about $180kgf/mm^2\~200kgf/mm^2$. NM wire developed as core of overhead conductor shows heat resistant characteristics higher than that of HC wire used as core of commercial ACSR overhead conductor, Strength loss was not occur at heat resistant test below $600^{\circ}C$. Fatigue strength of vibration fatigue is about $32kgf/mm^2\~35kgf/mm^2$ and that of tension-tension fatigue is $90kgf/mm^2\~120kgf/mm^2$ which is $50\~65\%$ of tensile strength.

Mechanical Properties of Insulator FRP Rod According to the Winding Orientation of Glass Fiber (유리섬유의 배향에 따른 전기절연용 FRP의 강도특성)

  • Park, Hyo-Yeol;Gang, Dong-Pil;Han, Dong-Hui;Pyo, Hyeon-Dong;Kim, Tae-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.6
    • /
    • pp.321-327
    • /
    • 2000
  • FRP has been used very much as high strength and electrical insulation materials. The fiber contributes the high strength and modulus to the composite. The main roles of the matrix in composite materials like FRP are to transmit and distribute stresses among the individual fibers. The fiber orientation in FRP has a great effect on the strength of FRP because the strength of FRP mainly depends on the strength of fiber. In this study, compressive and bending stresses of FRP rods were simulated and measured according to the winding orientation of glass fiber. Inner part of FRP was made unidirectionally by pultrusion method and outer part of FRP was made by filament winding method to give fiber orientation to the FRP. The shear stresses had great effect on the strength of FRP although the stress of parallel direction of FRP was much higher. The tendency of compressive and bending strengths with glass fiber orientation was different each other.

  • PDF

Electrical Insulation Properties of Nanocomposites with SiO2 and MgO Filler

  • Jeong, In-Bum;Kim, Joung-Sik;Lee, Jong-Yong;Hong, Jin-Woong;Shin, Jong-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.6
    • /
    • pp.261-265
    • /
    • 2010
  • In this paper, we attempt to improve the electrical characteristics of epoxy resin at high temperature (above $80^{\circ}C$) by adding magnesium oxide (MgO), which has high thermal conductivity. Scanning electron microscopy (SEM) of the dispersion of specimens with added MgO reveals that they are evenly dispersed without concentration. The dielectric breakdown characteristics of $SiO_2$ and MgO nanocomposites are tested by measurements at different temperatures to investigate the filler's effect on the dielectric breakdown characteristics. The dielectric breakdown strength of specimens with added $SiO_2$ decreases slowly below $80^{\circ}C$ (low temperature) but decreases rapidly above $80^{\circ}C$ (high temperature). However, the gradient of the dielectric breakdown strength of specimens with added MgO is slow at both low and high temperatures. The dielectric breakdown strength of specimens with 0.4 wt% $SiO_2$ is the best among the specimens with added $SiO_2$, and that of specimens with 3.0 wt% and 5.0 wt% MgO is the best among those with added MgO. Moreover, the dielectric strength of specimens with 3.0 wt% MgO at high temperatures is approximately 53.3% higher than that of specimens with added $SiO_2$ at $100^{\circ}C$, and that of specimens with 5.0 wt% of MgO is approximately 59.34% higher under the same conditions. The dielectric strength of MgO is believed to be superior to that of $SiO_2$ owing to enhanced thermal radiation because the thermal conductivity rate of MgO (approximately 42 $W/m{\cdot}K$) is approximately 32 times higher than that of $SiO_2$ (approximately 1.3 $W/m{\cdot}K$). We also confirmed that the allowable breakdown strength of specimens with added MgO at $100^{\circ}C$ is within the error range when the breakdown probability of all specimens is 40%. A breakdown probability of up to 40% represents a stable dielectric strength in machinery and apparatus design.

The Influence of Gap Length and Tip Radius on Breakdown of Electrical Insulating Oil (전기절연유의 절연파괴에 미치는 전극간격 및 곡률반경의 영향)

  • Kang, Seong-Hwa;Chae, Hong-In;Lee, Jong-Pil;Lim, Kee-Joe
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.56-59
    • /
    • 2004
  • In this paper, we investigated the influence of gap length and tip radius on breakdown of mineral based insulation oil. Applied voltages were DC and AC voltage. Electrode system was needle-plane structure. The tip radius of needle electrode was 5, 10, 20 and 25${\mu}m$, respectively. We measured breakdown voltage for each of tip radius with increasing electrode gap, 2mm to 12mm. Electric breakdown strength at tip was calculated using Mason's equation contained geometric figure. As gap length increased, breakdown strength increased linearly. But, as tip radius of needle increased, breakdown strength decreased exponentially. It can be explained by the phenomenon that electron is easily injected, as tip radius increases, and effective work function decreases. When appling DC voltage, breakdown strength was higher when polarity of needle was negative than positive. It is because of the space charge effect in accordance with the influence of liquid motion.

Utilization of Kota stone slurry powder and accelerators in concrete

  • Devi, Kiran;Saini, Babita;Aggarwal, Paratibha
    • Computers and Concrete
    • /
    • v.23 no.3
    • /
    • pp.189-201
    • /
    • 2019
  • Recent advances in the concrete technology are aiding in minimizing the use of conventional materials by substituting by-products of various industries and energy sources. A large amount of stone waste i.e., dust and slurry form both are being originated during natural stone processing and causing deadily effects on the environment. The disposal problem of stone waste can be resolved effectively by using waste in construction industries. In present work, Kota stone slurry powder, as a substitution of cement was used along with accelerators namely calcium nitrate and triethanolamine as additives, to study their impact on various properties of the concrete mixtures. Kota stone slurry powder (7.5%), calcium nitrate (1%) and triethanolamine (0.05%) were used separately as well in combination in different concrete mixtures. Mechanical Strength, modulus of elasticity and electrical resistivity of concrete specimens of different mix proportions under water curing were studied experimentally. The durability properties in terms of strength and electrical resistivity against sulphate and chloride solution attack at various curing ages were also studied experimentally. Results showed that accelerators and Kota stone slurry powder separately enhanced the mechanical strength and electrical resistivity; but, their combination decreased strength at all curing ages. The durability of concrete specimens was also affected under the exposure to chemical attack too. Kota stone slurry powder found to be the most effective material among all materials. Material characterization was also done to study the microstructural properties.

Changes in Flexural Strength and Electrical Resistivity of Bulk Graphite According to the Viscosity of Impregnant (함침재의 점도에 따른 벌크흑연의 굽힘강도 및 전기비저항 변화)

  • Lee, Sang-Min;Lee, Sang-Hye;Roh, Jae-Seung
    • Korean Journal of Materials Research
    • /
    • v.31 no.2
    • /
    • pp.108-114
    • /
    • 2021
  • In the manufacturing of bulk graphite, pores produced by vaporization and discharge of volatile materials in binders during carbonization reduce the density of bulk graphite, which adversely affects the electrical conductivity, strength and mechanical properties. Therefore, an impregnation process is introduced to fill the pores and increase the density of bulk graphite. In this study, bulk graphite is prepared by varying the viscosity of the impregnant. The microstructure of bulk graphite is observed. The flexural strength and electrical resistivity are measured. As the viscosity of the impregnants decreases and the number of impregnations increases, it is shown that the number of pores decreases. The density before impregnation is 1.62 g/㎤. The density increases to 1.67 g/㎤ and porosity decreases by 18.6 % after three impregnations using 5.1 cP impregnant, resulting in the best pore-filling effect. After three times of impregnation with a viscosity of 5.1 cP, the flexural strength increases by 55.2 % and the electrical resistivity decreases by 86.76 %. This shows that a slight increase in density due to the pore-filling effect improves the properties of bulk graphite.

An insight into the prediction of mechanical properties of concrete using machine learning techniques

  • Neeraj Kumar Shukla;Aman Garg;Javed Bhutto;Mona Aggarwal;M.Ramkumar Raja;Hany S. Hussein;T.M. Yunus Khan;Pooja Sabherwal
    • Computers and Concrete
    • /
    • v.32 no.3
    • /
    • pp.263-286
    • /
    • 2023
  • Experimenting with concrete to determine its compressive and tensile strengths is a laborious and time-consuming operation that requires a lot of attention to detail. Researchers from all around the world have spent the better part of the last several decades attempting to use machine learning algorithms to make accurate predictions about the technical qualities of various kinds of concrete. The research that is currently available on estimating the strength of concrete draws attention to the applicability and precision of the various machine learning techniques. This article provides a summary of the research that has previously been conducted on estimating the strength of concrete by making use of a variety of different machine learning methods. In this work, a classification of the existing body of research literature is presented, with the classification being based on the machine learning technique used by the researchers. The present review work will open the horizon for the researchers working on the machine learning based prediction of the compressive strength of concrete by providing the recommendations and benefits and drawbacks associated with each model as determining the compressive strength of concrete practically is a laborious and time-consuming task.

Mechanical Properties of FRP for Electrical Insulators (전기절연용 FRP의 강도특성)

  • Park, Hoy-Yul;Kang, Dong-Pil;Han, Dong-Hee;Pyo, Hyun-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1572-1574
    • /
    • 1999
  • FRP has been used very much as high strength core materials for insulators because of its high strength and good insulation properties. The fiber orientation of FRP has a great effect on FRP strength because the strength of FRP mainly depends on the strength of fiber. In this study, compression and bending stress were simulated along to the orientation of glass fiber. In addition, FRP was made by pultrusion and filament winding method. The compression and flexural strength were measured. The tendency of compression and flexural strength according to the fiber orientation of practical measured value of FRP was similar to simulated results.

  • PDF