• Title/Summary/Keyword: Electrical stimulation therapy

Search Result 431, Processing Time 0.02 seconds

The Comparison Effects between Electrical Stimulation Therapy and Isometric Exercise on Improvement of Biceps brachii Muscle Strength (EST와 등척성 운동이 상완이두근의 근력증진에 미치는 효과에 관한 비교연구)

  • Kim, Jeong-Seon;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • Purpose : To compare the effect between isometric exercise group(n=10) and electrical stimulation therapy group(n=10) on improvement of biceps brachii muscle strength. Methods : The experiments were performed for 4 weeks and three times a week. The participants of this study were 20 students(10 male, 10 female) who had not any medical problems. We divided into the two groups. One group received isometric exercise and the other group received EST for 4 weeks. The biceps brachii muscle strength was evaluated by making use of the KIN-COM. Results : The results were as follows 1. One group which received isometric exercise increased 36% for biceps brachii muscle strength. 2.The other group which received EST increased 54% for biceps brachii muscle strength. Conclusion : The results of this study showed that EST group was more effective than isometric exercise group.

  • PDF

Effects of Electrical Stimulation on Muscle functional Change (전기자극이 근기능 변화에 미치는 효과)

  • Joung, Ho-Bal;Ko, Tae-Sung
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.4
    • /
    • pp.105-112
    • /
    • 2002
  • When any damage or disease occurs, muscular strength and muscular endurance are lowered, and thus, if one is able to be restored from the damage or the disease, appropriate stimulus is required, since the muscles have to restore their proper functions. For such stimulus, the way of exercising and the way using electric stimulus are used in physical therapy. In order to examine the change in muscular strength, muscular endurance and girth of limbs for Biceps brachii, according to the lands of stimulus, in this article a total of 42 healthy male and female adults in their twenties were randomly sampled, and a series of tests were conducted for 6 weeks, for 15 minutes per once, 3 times per week, respectively, dividing them into the group for RUS(Russian Current Stimulation), PRE(Progressive Resistive Exercise) and P+R(RUS + PRE). The findings showed that the change in muscular strength was most significant as for the group for P+R, since it increased from $62.12{\pm}25.30$ before experiment to $95.78{\pm}34.07$ after 6 weeks: the change in muscular endurance was most significant as for the group for P+R, since it increased from $17.57{\pm}6.63$ to $42.86{\pm}10.24$; and the change in the girth of limbs was slightly significant only in the group for P+R, and the remaining two groups showed no significance.

  • PDF

Effects of Auricle Electric Stimulation on Pain, Gait and Balance in the Old Aged with Knee Joint Disease (외이전기자극이 슬관절질환 노인의 통증과 보행 및 균형에 미치는 영향)

  • Seo, Sam-Ki;Cho, Woon-Su;Lee, Jeong-Woo;Kim, Yong-Nam;Jung, Jin-Kyue;Hwang, Tae-Yeun
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.2
    • /
    • pp.11-17
    • /
    • 2008
  • Purpose: This study examined the application of electric stimulation to the auricle acupoint (frequency 2 Hz, stimulation level: noxious) with 30 elderly people over 65 years that received treatment in a rural hospital to determine the influence of pain, gait and balance in the aged with knee joint disease. Methods: The subjects were divided into three groups; the degenerative joint diseases (DJD) group (1 male, 9 females), the total knee replacement (TKR) group (1 male, 9 females) and the control group (1 male, 9 females). Auricualr electrical stimulation (AES) was applied with low frequency, high intensity transcutaneous electrical nerve stimulation for 10 seconds per each point. Results: 1. For the change of pain according to AES, there was interaction in the resting period (p<0.001) and gait (p<0.001) and pain of the DJD group and TKR group was decreased. 2. The range of motion (ROM) of the knee joint showed a significant difference in interaction for each group of elderly people (p<0.001) and the ROM for the DJD group and TKR group of elderly people was increased. 3. In the analysis of gait speed changes, there was a significant difference in interaction for each group of elderly people (p<0.001) and for gait speed in the DJD group and TKR group of elderly people. 4. It was found in the change of static balance that there was a significant difference in interaction for each group of elderly people (p<0.01) and balance capacity in the DJD group and TKR group of elderly people was increased. Conclusion: The aged with knee joint disease have pain, and a decreased function of gait and balance. AES was an excellent treatment for control of pain, and an excellent treatment to enhanced joint functions. AES was useful for improving gait and balance due to decreased pain.

  • PDF

The Effects of Auricular Electroacustimulation and Transcutaneous Electrical Nerve Stimulation on Postoperative Pain Control in Total Knee Replacement Patients (외이전기경혈자극과 경피전기신경자극이 슬관절 전 치환슬 환자의 수술 후 통증조절에 미치는 효과)

  • Kim, Tae-Youl;Hwang, Tae-Yeun;Huh, Choon-Bok
    • Journal of Korean Physical Therapy Science
    • /
    • v.1 no.1
    • /
    • pp.145-163
    • /
    • 1994
  • This study was done to determine differences in effect of postoperative pain control in patients receiving auricular electroacustimulation vs transcutaneous electrical nerve stimualtion following total knee replacement surgery. Thirty-one cases referred to physical therapy department after treated by total knee replacement surgery by orthopedic surgery department at the Pohang St. Mary's Hospital from January 1993 through June 1994. Of 31 total knee replacement cases, 13 cases were auricular electroacustimulation group, 11 cases were transcutaneous electrical nerve stimulation group, and 7 cases were control group. The results of the study summerized are as follows: Thirty-one total knee replacement cases(male in 12 cases, female in 19 cases), ranging in age from 34 to 61 years(mean${\pm}$SD=49.90 7.56) with diagnoses of degenerative arthritis(20 cases), rheumatoid arthritis(9 cases), and other(2 cases). In auricular electroacustimulation group, there was a significant change of pain intensity, unpleasantness, and active range of motion after treatment(p<0.01). In transcutaneous electrical nerve stimulation group, there was a significant change of pain intensity, unpleasantness, and active range of motion after treatment(p<0.01). In control group, did not show significant pre-posttreatment differences in pain intensity, unpleasantness, active range of motion(p>0.05). The mean change in pain intensity and unpleasantness, active range of motion from pretreatment baseline for the 3 groups. Auricular electroacustimulation group showed the large magnitude of increase in pain intensity and unpleasantness, active range of motion when compared to its own pretreatment cycle. Transcutaneous electrical nerve stimulation group showed small magnitude of increase in pain intensity and unpleasantness, active range of motion when compared to its own pretreatment cycle. No significant changes were observed in control group. Highly significant differences in pain intensity, unpleasantness, and active rage of motion were found using an ANOVA measures between treatment groups and control group(p<0.01). The squares correlation coefficients of pain and function measures pretreatment-posttreatment differences for each group. In treatment group, there was significant correlation between pain scale and function(p<0.001). In control group, there was no correlation between the pain scale and function (p>0.05). The continuous study is needd for many interesting issues of auricular electroacustimulation in new future.

  • PDF

The Change of The Effect on The Subcutaneous Fat Area and Visceral Fat Area by The Functional Electrical Stimulation and Aerobic Exercise (기능적 전기 자극과 유산소 운동이 복부비만의 피하지방과 내장지방에 미치는 효과)

  • Oh Sung-tae;Lee Mun-hwan;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.85-123
    • /
    • 2004
  • Back ground : Subcutaneous fat area is the main factor involved in replacement disease and arteriosclerosis. Simple weight control is the appropriate medical treatment. It's understood that weight reduction does not only reduce the fat concentrations in blood but also reduces blood pressure, improves glucose levels in diabetes patients and reduces incidents of heart disease. there are several methods for reducing fat in the abdominal region but their effectiveness is not folly understood. one method is electrical stimulation of the problem areas. Method : From May 1st 2002 to October 31st. The 15 subjects who received medical examination were aged between 25 and 53 and were of mixed gender. The subjects were divided into two groups one to received functional electrical stimulation and the other a control group. Using Broca's criterion for judging fat grades. I analysed the differences between the two groups before and after the treatment. Subjects received functional electrical stimulation on the abdominal muscle intensity 50Hz. They received this treatment 4 days a week for 40 minutes a day. In the case of aerobic exercise, at the Treadmill, we used it with the intensity of $75\%$ maximum heart rate (220-age). Result 1)After functional electrical stimulation in the case of male subjects, the weight was reduced 1.93kg, obesity $2.60\%$, fat mass 2.73kg, Percent body fat $4.40\%$, waist circumference 6.53cm, circumference of hips 5.53cm. On the other side, the quality of muscle was increased at the rate of 1.03kg, but it's not attentional level. The subcutaneous fat area was reduced by $26.63cm^2$, the visceral fat area was reduced by $43.00cm^2$, In the female subjects, we can see the reduction of fat grade by $26.63cm^2$, the quantity of body fat by 1.5kg, percent body fat by $1.77\%$, circumference of waist by 4.02cm, circumference of hips by 3.67cm, weight by 1.40kg but was increased 0.72kg at the quantity of muscles. We can see the reduction also in the subcutaneous fat area $24.03cm^2$, the visceral fat area by $25.36cm^2$. 2)After aerobic exercise, on the male subjects, we can see reduction of weight by 3.36kg, obesity by $4.00\%$, fat mass by 2.83kg and we can see increase at the soft lean mass by 2.96kg, but we can see reduction, the percent body fat by $3.03\%$, fat distribution by $0.023\%$, circumference of waist by 3.10cm, circumference of hips by 2.23cm. The female subjects show a reduction in the weight by 2.48kg, percent body fat by $2.20\%$, show an increase in the soft lean mass by 1.54kg. We can see a reduction in the quantity of fat mass by 2.32kg, the percent body fat by $2.80\%$, the circumference of waist by 2.16cm, the circumference of hips by 2.68cm, the fat distribution by $0.016\%$, the subcutaneous fat area by $15.25cm^2$ the visceral fat area by $11.52cm^2$. After aerobic exercise, we can't see the attentional change at the total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. 3)After the application of functional electrical stimulation and aerobic exercise, in result of measurement on the body ingredient, we could see the weight reduction and increase the quantity of muscle with the male group who exercised aerobic. We can see the attentional rate on the electrical stimulation about abdominal fat rate, circumference of waist, circumference of hips. The other hand, I couldn't see the attentional differences between the two groups in the rate of fatness and quantity of body fat and the rate of body fat. There isn't any attentional difference in the area of fat under skin, on the contrary, There is attentional difference in the fat in the internal organs area at the electrical stimulation site. We can't see the attentional change of total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol between electrical stimulation and aerobic exercise. 4)After execution of functional electrical stimulation and aerobic exercise, in result of measurement on change of body ingredient among female objects, We could see weight reduction, increase at muscle quantity in the aerobic exercise group. We could see the attentional differences in the rate of fatness, the rate of abdominal region, the circumference which received electrical stimulation. But, we couldn't see the attentional differences between two groups in the quantity of body fatness, the circumference of hips. The subcutaneous fat area doesn't show the attentional differences. On the Contrary, we could see lots of differences in the visceral fat area of the electrical stimulation group. Conclusion The results show that functional electrical stimulation and aerobic exercise have insignificant differences when if comes to total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. Though there is affirmative change in body ingredient after both electrical stimulation and aerobic exercise. Functional electrical stimulation is more effective on the subcutaneous fat area and in changing visceral fat area. There fore. It is concluded that the physical therapy is more effective in the treatment of abdominal fatness.

  • PDF

Changes of Electroencephalogram according to Contraction Training Methods of Tibialis Anterior Muscle in Healthy Women (정상 여성에게서 앞 정강근의 수축훈련방법에 따른 뇌파의 변화)

  • Lee, Jeong-Woo;Kim, Moon-Jeong;Yoon, Se-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.127-133
    • /
    • 2012
  • Purpose: This study aims to examine the power changes in eletrocenphalogram (EEG) detected from the tibialis anterior muscle, during repetitive contraction exercise in normal female adults. Methods: The subjects of this study were 24 normal adult females, with no musculoskeletal or nervous system disorders. The 24 female subjects were divided into two groups: 12 subjects comprised a voluntary stimulation training group, and the other 12 subjects comprised an electrical stimulation training group. A total of thirty contractions were made repetitively by each woman, with maximal voluntary contraction exercise for six seconds, and a resting time of three seconds. During the experiment, their EEG was measured at eight positions. The eight positions were Fpz, Fz, Cz, CPz, C3, C4, P3, and P4, in accordance with the international 10~20 system. Results: The relative alpha power and beta power showed no statistically significant differences between the two groups. But the relative gamma power of the CPz, C3, C4, P3, and P4 areas showed statistically significant differences between the two groups (p<0.05). The relative theta power of the C4 area showed statistically significant differences between the two groups (p<0.05). Conclusion: Our findings show that tibialis anterior muscle contraction by electrical stimulation and by voluntary repeated contraction differentially affected brain activation. In particular, the CPz, C3, C4, P3 positions of relative gamma power showed brain activation in voluntary contraction. The C4 position of relative theta power showed different brain activation between the two groups.

Effects of Weight-Bearing Training with Elastic Bands on less - Affected Side during Functional Electronic Stimulation on Walking and Balance in Stroke Patients (기능적 전기자극시 비 마비측에 탄력밴드를 적용한 체중지지훈련이 뇌졸중 환자의 보행과 균형에 미치는 영향)

  • Jeong, Chae-min;Woo, Young-Keun;Won, Jong-im;Kim, Su-Jin
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.417-430
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the effect of weight-bearing training with an elastic band during functional electrical stimulation (FES) on walking and balance functions in stroke patients. Methods: Twenty patients with chronic stroke were divided into an experimental group assigned to weight-bearing training with an elastic band during functional electrical stimulation (FES; n=10) and a control group assigned to weight-bearing training alone during FES (n=10). The patients in both groups attended physical therapy sessions five times a week for four consecutive weeks. The experimental group underwent weight-bearing training with an elastic band during FES five times a week for four weeks. The control group underwent weight-bearing training during FES. Balance parameters were measured before and after the intervention using the Balancia program. Moreover, all patients were evaluated using the Berg Balance Scale (BBS), the Time Up and Go Test (TUGT), and the Wisconsin Gait Scale (WGS) before and after each intervention. Results: The results showed that weight-bearing training with elastic bands during FES and weight-bearing training during FES had a significant effect on the affected side's weight-bearing ratio, BBS, TUGT, and WGS in both groups (p <0.05). Additionally, the results showed that the changes observed in the two groups indicate significant differences in path length, average speed, BBS score, TUGT time, and WGS score between the groups (p < 0.05). Conclusion: In patients with stroke, weight-bearing training with an elastic band during FES affected on walking and balance. Therefore, it is an optional intervention for the balance and walking ability of stroke patients.

Effects of Transcutaneous Electrical Nerve Stimulation(TENS), Self-Stretching and Functional Massage on the Muscle Fatigue by Maximum Muscular Strength

  • Yoon, Jung Gyu;Ryu, Je Ju;Roh, Hye Won;Yang, Hyun Ah;Lee, Sang Bin
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.2
    • /
    • pp.422-428
    • /
    • 2012
  • The present study purposed to examine the effects of transcutaneous electrical nerve stimulation, self-stretching and functional massage on the recovery of muscle contraction force for muscle fatigue caused by sustained isotonic contraction. The subjects of this study were 45 healthy students. They were divided into transcutaneous electrical nerve stimulation group(n=15), self-stretching group(n=15) and functional massage group(n=15), and using Primus RS. We observed the pattern of changes in maximal voluntary isometric contraction force(MVIC) after causing muscle fatigue in quadriceps femoris muscle through sustained isotonic contraction. Maximal voluntary isometric contraction force(MVIC) were greatly increased after transcutaneous electrical nerve stimulation, self-stretching and functional massage. In the comparison of recovery rate of muscle contraction force for muscle fatigue caused by sustained isotonic contraction among the treatment groups, it did not show any significant differences. However, it showed that each treatment may be effective in recovery of muscle fatigue caused by sustained isotonic contraction.

Effects of Transcutaneous Electrical Nerve Stimulation and Laser at Auricular Points on Experimental Cutaneous Pain Threshold (외이에 대한 경피신경 전기자극과 레이저가 실험적 피부 통증역치에 미치는 영향)

  • Sim, Youn-Ju;Lee, Mi-Sun;Lee, Yun-Ju
    • Physical Therapy Korea
    • /
    • v.4 no.1
    • /
    • pp.87-94
    • /
    • 1997
  • The purposes of this study were 1) to determine the changes between pre-treatment and post-treatment of four groups of 15 persons each and 2) to compare the effect of conventional transcutaneous electrical nerve stimulation(TENS) and laser at auricular acupuncture points on experimental pain threshold measured at the wrist. Sixty healthy adult men and women(M:32, F:28), aged 20 to 28 years, were assigned randomly to one of four groups. Group 1 received TENS to the appropriate auricular point for wrist pain, Group 2 received laser to the appropriate auricular point for wrist pain, Group 3 received placebo TENS to the appropriate auricular point for wrist pain, Group 4 received no treatment and served as controls. Experimental pain threshold at the wrist was determined with a painful electrical stimulus before and 20 minutes after ear stimulation. Group 1 was the only group that showed a stastically significant increase (p<0.05) in pain threshold after treatment whereas the Group 2,3 and 4 did not. These results suggest that TENS has the capability to higher pain threshold but laser does not.

  • PDF

Effect of electrical stimulation on disused rat soleus (전기자극이 흰쥐의 가자미근 무용성 위축에 미치는 영향)

  • Bae Sung Soo;Park Rae Joon;Kim Jin Sang;Park Sang OK
    • The Journal of Korean Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.175-188
    • /
    • 1991
  • A study was performed to investigate the effect of electrical stimulation on disused rat soleus muscle, of male rat. The animal's hindlimbs were immobilized 4weeks by plaster of paris, and stimulated with E. S. T for 4weeks (20min/day) The changes on soleus were examined with histochemical, histological, and morphometric method. The results are summarized as follows. 1. Disued atrophy group from immobilization, which margin of sarcolemma and myofibril in sarcoplasm were not cleared, also degenerated from necrosis with phagocytosis. 2. The numbers of nuclear were much increased and accumulation of nuclear were finded, and relatively muscular atrophic changed. 3. Increased inflammatory cyte, also finded neutrophil and macrophage. 4. Relatively atrophic changed from severe fibrosis by incleased connectivetissue. 5. The glycogen granules were much decreased in E. S. T group. It means that electrical stimulation effected the muscle exercise. 6, The activity of the NADH-TR reaction of E. S. T. Tgroup were white muscle group are transformed into red muscle fiber than normal group. 7. These results indicate that the electrical stimulation effected to soleus also prevention and delayed muscular atrophy.

  • PDF