• 제목/요약/키워드: Electrical stability

검색결과 4,453건 처리시간 0.031초

Lyapunov 함수를 이용한 동기전동기의 안전도 해석과 동특성 시뮬레이션 (Stability Analysis of Synchronous Motor by Lyapunov Functions and Dynamic Simulation)

  • 이준탁;윤병도;우중인;정형환
    • 대한전기학회논문지
    • /
    • 제39권11호
    • /
    • pp.1163-1173
    • /
    • 1990
  • In the stability analysis of a synchronous motor, the considerations of the initial conditions, that is, field application points and the determination techniques of stability regions to assure stable operations over four quadrants are very important. In this paper, Lyapunov stability regions obtained from a newly proposed algorithm with Lyapunov function of simple type on the basis of numerical analysis method are shown to be true stability regions which can accurately pull in within 2 (rad) after field application.

뉴트럴 시간지연 시스템의 강인 지연의존 안정성 해석을 위한 새로운 리아프노프 함수법 (A New Augmented Lyapunov Functional Approach to Robust Delay-dependent Stability Analysis for Neutral Time-delay Systems)

  • 권오민
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.620-624
    • /
    • 2011
  • This paper propose a new delay-dependent stability criterion of neutral time-delay systems. By employing double-integral terms in augmented states and constructing a new Lyapunov-Krasovskii's functional, a delay-dependent stability criterion is established in terms of Linear Matrix Inequality. Through numerical examples, the validity and improvement results obtained by applying the proposed stability criterion will be shown.

반복 조류 계산 기법에 의한 STATCOM 적용 전력시스템의 전압 안정도 향상 연구 (A Study on Voltage Stability Enhancement of Power Systems with STATCOM using Repeated Power Flow Method)

  • 이세정;이병하;원종률
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.146-148
    • /
    • 2001
  • The STATCOM(Static Compensator) resulted from the FACTS technology can generate or absorb reactive power rapidly so as to increase the transient stability and voltage stability. In this paper, effects of application of the STATCOM to the power system are analyzed from a viewpoint of improving voltage stability. The voltage stability is analyzed by use of repeated power flow method. The IPLAN, which is a high level language used with PSS/E program, is employed for evaluating the voltage stability.

  • PDF

G-parameter를 이용한 직류 마이크로그리드의 컨버터 상호 안정도 분석 및 가상 임피던스를 이용한 안정도 향상 (Stability Analysis Using G-Parameters of Converters Constituting DC Microgrid and Stability Enhancement Through Virtual Impedance)

  • 이재석;이기영;김래영
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.321-327
    • /
    • 2018
  • DC microgrid system composed of multiple converters has a tendency to make the system unstable due to the interaction of converters. To solve this problem, in this paper, the interaction between cascaded converters with LC input filter is analyzed with impedance modeling using g-parameter. The input impedance and the output impedance of the system can be obtained through this technique. The stability of the system can be determined by applying Middlebrook's stability criterion to the impedance. Virtual impedance is added to the controller to enhance stability. The validity of the analysis is verified by the result of several simulations and experiments.

전력계통의 안정도 진단이 가능한 선로 선정에 관한 연구 (Identification of Correlative Transmission Lines for Stability Diagnosis of Power System)

  • 조윤성;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.271-278
    • /
    • 2003
  • Power system stability is correlated with system structure, disturbances and operating conditions, and power flows on transmission lines are closely related with those conditions. This paper proposes a methodology to identify correlative power flows for power system transient and small-signal stability prediction. In transient stability sense, the Critical Clearing Time is used to select some dominant contingencies, and Transient Stability Prediction index is proposed for the quantitative comparison. For small-signal stability, this paper discusses a methodology to identify crucial transmission lines for stability Prediction by introducing a sensitivity factor based on eigenvalue sensitivity technique. On-line monitoring of the selected lines enables to predict system stability in real-time. Also, a Procedure to make a priority list of monitored transmission lines is proposed. The procedure is applied to a test system and the KEPCO systems in the year of 2003 and it shows capabilities of the proposed method

A Note on Schur Stability of Real Weighted Diamond Polynomials

  • Otsuka, Naohisa;Ichige, Koichi;Ishii, Rokuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.421-424
    • /
    • 2004
  • This paper presents a sufficient condition for the real weighted diamond polynomials to be Schur stable using bilinear transformation and Kharitonov's theorem.

  • PDF

퍼지 리아푸노프 함수를 이용한 어파인 퍼지 시스템의 완화된 안정도 조건 (Relaxed Stability Condition for Affine Fuzzy System Using Fuzzy Lyapunov Function)

  • 김대영;박진배;주영훈
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1508-1512
    • /
    • 2012
  • This paper presents a relaxed stability condition for continuous-time affine fuzzy system using fuzzy Lyapunov function. In the previous studies, stability conditions for the affine fuzzy system based on quadratic Lyapunov function have a conservativeness. The stability condition is considered by using the fuzzy Lyapunov function, which has membership functions in the traditional Lyapunov function. Based on Lyapunov-stability theory, the stability condition for affine fuzzy system is derived and represented to linear matrix inequalities(LMIs). And slack matrix is added to stability condition for the relaxed stability condition. Finally, simulation example is given to illustrate the merits of the proposed method.

실시간 전압안정도 프로그램을 이용한 제주지역 전압안정도 (Jeju area's Voltage Stability Analysis which use the Real Time Voltage Stability Analysis Program)

  • 이성우;안교상;서동완;장문종
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1387-1392
    • /
    • 2012
  • These days people use a lot of electric power, because industry advancement and a standard of living is elevated. So voltage stability analysis and control problems are very important in these days. U.S.A has already developed voltage stability analysis program, and use it on power transmission scheme such as generator overhaul, transmission line off and so on. So voltage stability analysis is more and more interested in Korea, too. In this paper, we introduce a standard theory of voltage stability analysis and real time voltage stability analysis program that use sPMU(Satellite Phasor Measurement Unit). And we also introduce the calculation result about voltage stability in Jeju power transmission system.

태양광 전력설비를 위한 오차 보상기 사용의 전력변환기기에 대한 응답특성의 효과 검증 (Response Characteristics Effectiveness of Power Converter According to Using of Error Compensator for PV Power System)

  • 김동은;이현재;손진근
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1388-1394
    • /
    • 2018
  • In this paper, the improvement of the control response by using the error compensator to improve the stability of the control in the power conversion system is verified. Typically a closed loop control method is used to improve the control response characteristics in a traditional power conversion system and this is accomplished by generating a PWM waveform. In this paper, the newly constructed Type3 compensator to overcome the existing such as PI controller or Type2 compensator has been developed to improve the control stability of these closed loop control systems and the effectiveness of the use of error compensation devices was verified by presenting technique to improve stability and select its parameters by expanding the range of phase gains. Stability improvements are shown by the extension of the phase gain range and parameter selection techniques and the effects of using the error compensation device are verified accordingly.

Effect of Circuit Parameters on Stability of Voltage-fed Buck-Boost Converter in Discontinuous Conduction Mode

  • Feng, Zhao-He;Gong, Ren-Xi;Wang, Qing-Yu
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1283-1289
    • /
    • 2014
  • The state transition matrix are obtained by solving state equations in terms of Laplace inverse transformation and Cayley-Hamilton theorem, and an establishment of a precise discrete-iterative mapping of the voltage-fed buck-boost converter operating in discontinuous conduction mode is made. On the basis of the mapping, the converter bifurcation diagrams and Lyapunov exponent diagrams with the input voltage, the resistance, the inductance and the capacitance as the bifurcation parameters are obtained, and the effect of the parameters on the system stability is deeply studied. The results obtained show that they have a great influence on the stability of the system, and the general trend is that the increase of either the voltage-fed coefficient, input voltage or the load resistance, or the decrease of the filtering inductance, capacitance will make the system stability become poorer, and that all the parameters have a critical value, and when they are greater or less than the values, the system will go through stable 1T orbits, stable 2T orbits, 4T orbits, 8T orbits and eventually approaches chaos.