A Study on the Shock Compaction of Ceramic Powders using Explosive (폭약을 이용한 세라믹분말의 충격고화에 관한 연구)

  • Kim, Young-Kook;Kim, See-Jo;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.22 no.2
    • /
    • pp.157-161
    • /
    • 2012
  • ZnO-98% and $Ga_2O_3$-2% powder were consolidated by shock compaction technique, which uses a high performance explosive. The microstructural and electrical characteristics of $ZnOGa_2O_3$ compact with density of 97% and hardness of 220~250 $H_v$ were investigated using SEM (Scanning Electron Microscope) and X-ray diffraction analysis, respectively. In the microstructures of the compact, there were no visible cracks at most of the surface areas, and interparticle bonding between powder particles was confirmed. The broadened peaks were detected due to deformation of crystallited size and high electric resistances were confirmed due to increased grains because of shock energy with a high pressure and high velocity.

Expression of Heat Shock Protein Protein 70 in Umbilical Vein Endothelial Cells Infected by Staphylococcus aureus

  • Chang, Hyun-Ah;Chang, Jun-Keun;Kim, Jong-Won;Kim, Mal-Nam
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.2
    • /
    • pp.137-142
    • /
    • 2000
  • Environmental stres is known to induce heat shock proteins (HSPs) in eukaryotic cells. However, the induction of HSPs in host cells by microbial infection has not yet been well explained. Staphylococcus aureus (S. aureus) is one of the major pathogens in the pathogenesis of endovascular diseases such as infective endocarditis. In this study, the synthesis of stress-inducible 70 kDa HSP was investigated in the endothelial cells (ECs) after 3 h to 20 h of incubation with S. aureus. The dffect of S. aureus infection on the expression of HSP70 in cultured ECs was analyzed using laser scanning confocal microscopy (LSCM). The increase of HSP70 expression in ECs infected by S. aureus ($10^4{\;}cfu/ml$) for 20 h was 1.1-fold higher than that in heat shock treated ECs and 2.2-fold higher than that in untreated cells. Heat shock is known to induce intranucleus HSP70 expression in mammalian cells, whereas the S. aureus infection induced perinuclear expression in ECs as observed by LSCM. Consequently, the expression of HSP70 in ECs plays an important role in the pathogenesis of endovascular infection.

  • PDF

A Study on Installation of Monitoring System of Wireless Power Transmission System (무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.

Protection ability for lightning surge according to the grounding system of low voltage power systems (저압 전원계통 접지방식별 뇌서지보호성능)

  • Lee, Bok-Hee;Lee, Gyu-Sun;Choi, Jong-Hyuk;Yoo, Yang-Woo;Kim, Dong-Sung;Kang, Sung-Man;Ann, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.343-346
    • /
    • 2009
  • The grounding system of low voltage power systems is TT grounding system in Korea. In order to follow the international standard, TN grounding system is adopted. However, the performance of grounding systems has not been evaluated. This paper deals with the experimental results of protection ability of grounding system when lightning surge invades to the neutral line of low voltage power system. As a result, the TT grounding system is most frail for the lightning surge and it does not protect the electrical devices. On the other hand, the TN grounding system perfectly protects the electrical equipment and prevents the electric shock for human through the equipotential bonding. In case of TN system with supplement grounding, it is very important to lower the supplement grounding resistance to protect the electrical equipment and electric shock for human.

  • PDF

Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement (반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템)

  • Jeon, Jeong Chay;Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Design of SDINS Rapid Initial Alignment Technique Robust to the Pyro-shock in Multi-Launch Rocket System (연속발사 충격에 강인한 SDINS 신속 초기정렬기법 설계)

  • Lee, Hyung-Sub;Han, Kyung-Jun;Lee, Sang-Woo;Yu, Myeong-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1038-1044
    • /
    • 2016
  • In this paper, a SDINS(Strapdown Inertial Navigation System) rapid initial alignment technique robust to the pyro-shock in multi-launch rocket system is proposed. The proposed method consists of three steps. Firth, transfer alignment is performed to estimate misalignment between MINS(Master INS) and SINS(Slave INS), and the estimated misalignment is written in the memory when transfer alignment is completed. Next, the pre-filtering process is performed to get rid of the acceleration error induced by launcher vibration. Finally, the horizontal alignment is performed to compensate misalignment variation caused by pyro-shock. We verified the performance of the proposed alignment method comparing with the conventional transfer alignment method. The simulation shows that the proposed initial alignment technique improves alignment performance.

A Method for Evaluating Electric Shock Hazards Based on Human Body Current (인체전류를 기반으로 하는 감전의 위험성 평가방법)

  • Lee, Bok-Hee;Yoo, Yang-Woo;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

Optimal Structural Design of a Tonpilz Transducer Considering the Characteristic of the Impulsive Shock Pressure (충격 특성을 고려한 Tonpilz 변환기의 최적구조 설계)

  • Kang, Kook-Jin;Roh, Yong-Rae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.987-994
    • /
    • 2008
  • The optimal structure of the Tonpilz transducer was designed. First, the FE model of the transducer was constructed, that included all the details of the transducer which used practical environment. The validity of the FE model was verified through the impedance analysis of the transducer. Second, the resonance frequency, the sound pressure, the bandwidth, and the impulsive shock pressure of the transducer in relation to its structural variables were analyzed. Third, the design method of $2^n$ experiments was employed to reduce the number of analysis cases, and through statistical multiple regression analysis of the results, the functional forms of the transducer performances that could consider the cross-coupled effects of the structural variables were derived. Based on the all results, the optimal geometry of the Tonpilz transducer that had the highest sound pressure level at the desired working environment was determined through the optimization with the SQP-PD method of a target function composed of the transducer performance. Furthermore, for the convenience of a user, the automatic process program making the optimal structure of the acoustic transducer automatically at a given target and a desired working environment was made. The developed method can reflect all the cross-coupled effects of multiple structural variables, and can be extended to the design of general acoustic transducers.

An Analysis for 18650 Li-Ion Cell Electrical Characteristics of Vibration and Shock Test (18650 리튬이온 셀의 진동 및 충격 시험 기반 전기적 특성 분석)

  • Yoon, Chang-O;Kim, Jong-Hoon;Jang, Min-ho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.313-314
    • /
    • 2016
  • 본 논문에서는 리튬이온(Li-Ion) 배터리 셀(Cell)의 Shock test와 Vibration test 기반 18650 원통형 셀 내부 전기적 특성 변화를 분석하였다. 전류적산법을 기반으로 방전 용량을 측정하였고, OCV(Open Circuit Voltage) 측정 및 HPPC(Hybrid Pulse Power Characterization) test를 기반으로 내부 저항을 측정하고 진동 및 충격 시험 전 후의 파라미터를 비교 분석하였다.

  • PDF

A Study on the Scheme of Ground Connection for the Mobile Generator (이동용 발전기의 접지방식에 관한 연구)

  • Cho, Kyu-Duek;Kim, Bong-Tae;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.81-84
    • /
    • 2001
  • In industrial field, especially the mobile generator is almost used as a islanding generator source for light, electric thrill, and compressor, and so on. However, because there still exists a lot of aged load, it causes the electric shock against person. In this paper authors introduce the proper method to reduce the electric shock in field discussing the scheme of ground connection.

  • PDF