• 제목/요약/키워드: Electrical safety system

검색결과 1,366건 처리시간 0.027초

애니메이션을 이용한 전기 안전 교육용 모바일 에이전트 기반 비디오 검색 시스템 (A Video Retrieval System for Animation Using Electric Safety Education Based on Mobile Agent)

  • 조현섭;민진경;유인호
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2006년도 춘계학술발표논문집
    • /
    • pp.320-323
    • /
    • 2006
  • Recently, retrieval of various video data has become an important issue as more and more multimedia content services are being provided. To effectively deal with video data, a semantic-based retrieval scheme that allows for processing diverse user queries and saving them on the database is required. In this regard, this paper proposes a semantic-based video retrieval system that allows the user to search diverse meanings of video data for electrical safetyrelated educational purposes by means of automatic annotation processing. If the user inputs a keyword to search video data for electrical safety-related educational purposes, the mobile agent of the proposed system extracts the features of the video data that are afterwards learned in a continuous manner, and detailed information on electrical safety education is saved on the database. The proposed system is designed to enhance video data retrieval efficiency for electrical safety-related educational purposes.

  • PDF

스마트그리드 연계 고객전기설비 전기안전 실시간 감시 및 관리 방안 (Real Time Monitoring and Management Method for Electrical Safety of Customer Electrical Installations Connected to Smart Grids)

  • 전정채;박찬엄;임용배;배석명
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.340-344
    • /
    • 2010
  • In order to achieve purpose of Smart Grids, which is effective use of electrical energy, the safety of electrical installations must be secured. This paper presented real time monitoring and management method for electrical safety of customer electrical installations connected to Smart Grids. And the direction of electrical safety system for the introduction of real time monitoring and management method was suggested. Efficiency improvement of electrical safety management and new supplementary services related with Smart Girds will be available by introducing the presented method.

The Characteristics of Arc Scattering and Fusing Current of Copper Wire in the Fault Process DB System of Cables in a PL Environment

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.52-58
    • /
    • 2008
  • The importance of. identifying the causes of electrical faults cannot be overstated because of the accidents caused by over-current that take place at the home, the office and electrical facilities due to misuse, poor products and system faults. It is necessary to gather objective, scientific data pertaining to electrical fault investigation in a product liability(PL) environment. To date, no database(DB) has been built concerning the accurate cause analysis of faultyfacilities. In this paper, accident hazard and arc scattering when over-current flows in copper wire was investigated. It was found that when over-current flows in a copper wire, the copper wire became heated and bent and beads were scattered around the wire with a flash. It was determinedthat the fusing current and time was related to the current rise per second. For example, when the current rise per second was largethe fusing current was higher than when the current rise per second was small, and the beads dispersed along a wide area. Fusing time, however, was shorter. The possibility of electrical fault became highest when the fusing current was higher. As the current rise per second is short, the dendrite structure is distributed in the surface of the copper wire. These experimental results can be utilized for a fault process DB system in the investigation and the prevention of electrical faults.

TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향 (Personnel safety related to a loss of PEN conductor in TN-C-S system)

  • 김정철;이복희;이규선;조정현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2009
  • In electrical power supply systems, an earthing system determines the electrical potential of the conductors relative to that of the Earth's conductive surface. The choice of earthing system has implications for the safety of the power supply. Note that regulations for earthing (grounding) systems vary considerably among different countries. A protective earth(PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth, This paper investigates that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage is caused at personnel body. According to this paper, we can understand that when TN-C-S system is applied in Korea, what we should set up to ensure the personnel safety from fault current.

  • PDF

저압용 누전차단기의 스위칭에 따른 아크 비산 및 접점의 특성분석 (The analysis of arc dispersion and contacts characteristics according to switching of RCD for low voltage)

  • 김동우;김향곤;길형준;한운기;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.69-73
    • /
    • 2005
  • The arc dispersion and contacts characteristics were analyzed according to switching off Residual Current Protective Device(RCD) switch. Arc dispersion process was taken by high speed imaging system at a rate of 10,000 frames per second. When RCD was switched from on to off, art was observed and it took about 2.3[ms] from the generation of arc to the extinction of arc. When RCD was switched from off to on, arc was not observed. We repeated switching on and off 1000, 3000 and 6000 times. After repetition, the surface characteristics of contacts were taken by stereo microscope and Scanning Electron Microscope(SEM). From the scattering patterns analysis of arc and the analysis of deteriorated contacts, it could be applicable to the research of electric fire and arc suppression.

  • PDF

DSP를 이용한 고조파 측정 및 분석 (Measurement and Analysis Harmonics Using DSP)

  • 이상익;유재근;전정채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.178-180
    • /
    • 2002
  • Limitation countermeasure on harmonics occurred by power conversion installation, motor speed control equipment, and so on of power system is very important problem, and first of all, accuracy harmonics analysis in system is required for appropriate limitation counterplan. Analysis and judgement on power system harmonic by measurement are needed because analysis by mathematical model generally used for these harmonic analysis, if nonlinear ingredient is included in system, is not relatively correct. So, in this paper, system to measure and analyze harmonic by installing it in a power system, using DSP(Digital Signal Processor), is designed and developed. Also, it's performance is verified by installing it in the system that harmonics occurred.

  • PDF

독립 전원설비에서의 접지방법 개선에 관한 연구 (A Study of Ground System improvement on Isolated Power Generation)

  • 류보혁;남택주;김정훈
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.96-102
    • /
    • 2001
  • In construction sites, portable generators and electrical equipments cause frequently electrical accidents due to the poor condition of their usage. However, there are very few technical guidelines on these equipments even though they have serious accident causing potentiality. In order to reduce such accidents in practical and economical, grounding methods are studied in this paper as the countermeasure of electrical accidents. Several Korean national standards and international standards regarding three grounding types are compared each other, and some prevention means of electrical accidents are reviewed in this study. This paper presents the most effective grounding methods by assuming the WCS with the isolated power systems.

  • PDF

인체감전 안전기준에 관한 최근 국제규격의 동향 (Recent Trend of International Standards on the Safety Criteria for Electric Shock Protection)

  • 이종철;김한수;이주철;강성만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.189-193
    • /
    • 2007
  • The grounding of an electrical system is one of the essential elements for public safety. Domestic practice of grounding system design has been to get grounding resistance values which are classified by facilities or equipment in the regulations. But the concept of grounding system design of IEC is, as a main factor of safety index, to consider touch voltage and step voltage instead of the resistance value itself. Recently IEC actively develops or revises safety related standards which are essential for the grounding system performance. In this paper, we present the recent trend of the international standards on the safety criteria for Electric Shock Protection.

  • PDF

Electrical Fire Cause Diagnosis System based on Fuzzy Inference

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.12-17
    • /
    • 2005
  • This paper aims at the development of an knowledge base for an electrical fire cause diagnosis system using the entity relation database. The relation database which provides a very simple but powerful way of representing data is widely used. The system focused on database construction and cause diagnosis can diagnose the causes of electrical fires easily and efficiently. In order to store and access to the information concerned with electrical fires, the key index items which identify electrical fires uniquely are derived out. The knowledge base consists of a case base which contains information from the past fires and a rule base with rules from expertise. To implement the knowledge base, Access 2000, one of DB development tools under windows environment and Visual Basic 6.0 are used as a DB building tool. For the reasoning technique, a mixed reasoning approach of a case based inference and a rule based inference has been adopted. Knowledge-based reasoning could present the cause of a newly occurred fire to be diagnosed by searching the knowledge base for reasonable matching. The knowledge-based database has not only searching functions with multiple attributes by using the collected various information(such as fire evidence, structure, and weather of a fire scene), but also more improved diagnosis functions which can be easily wed for the electrical fire cause diagnosis system.

LED 램프의 특성 분석을 통한 전기안전 관리 방안에 관한 연구 (Study on the Electrical Safety Management Method through the Electrical Characteristic Analysis of LED Lamps)

  • 이기연;문현욱;김동우;임용배;유인호
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1931-1936
    • /
    • 2016
  • In this paper, we analyzed causes of accidents that recently increased in the illegal and defective LED lamps. They were analyzed by the electrical characteristics calculation and reappearance experiments. The causes of the accidents were analyzed from the circuit affected by the variation of voltage, current and power by harmonics. We drew a conclusion for electrical safety in illegal or degraded LED lamps from the analysis result. The management factors for electrical safety in LED lamps were harmonics, reactive power and power factor. It is possible to secure the electrical safety through monitoring of power factor in failure products and available in smart meters or smart distribution boards.