Development of Black Box for Home Battery Energy Storage System Connected with Solar Energy Generation (태양광발전 연계 가정용 배터리 에너지저장장치의 블랙박스 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1295-1302
    • /
    • 2016
  • In this paper, a black box, which is provided the reliability and user safety of home battery energy storage system connected with solar energy generation, is developed. In the developed scheme, a status and diagnosis data of battery management system, power conditioning system, solar energy generation and grid is measured. This status and diagnosis data is stored and displayed in the developed black box. In addition, this status and diagnosis data is stored and displayed in a monitoring system and a smart phone of user. A performance evaluation of the developed black box is carried out using emulator of home battery energy storage system connected with solar energy generation. Consequently, the developed black box is proved its superiority of the reliability and user safety.

Internet Based Remote Control and Monitoring for Motor (인터넷기반 모터 원격제어 및 모니터링)

  • Kang, Shin-Young;Kim, Eun-Ju;Wi, Seog-Oh;Kim, Gwang-Heon;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.279-285
    • /
    • 2002
  • This Paper deals with the economical equipment control which is used by internet network system at the industrial workplace. If the control devices can be accessed by internet, we can have the developed possibility of work conditions. in this paper, we presented the advanced digital timer which has a communication function to control and observe panel to realize control solution based on internet to be easily applicable at workplace with low cost, and we used RS-485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet. As the result for experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.

Development of Monitoring System for Safety Operation of Crane (크레인 안전 운전을 위한 모니터링 시스템 개발)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.11
    • /
    • pp.1305-1310
    • /
    • 2014
  • In this paper, the new integrated crane monitoring system that complemented the point at issue for existing crane monitoring system is implemented. The Implementing monitoring system based on wireless communication system, consist of a measuring system of total load currents of main circuit breaker, a temperature and vibration measuring system with temperature sensors and vibration sensors for monitoring an oil and bearing of a main decelerator, a temperature measuring system with temperature sensors of a main motor bearing, and sensors for fire monitoring of an entire electrical space. The measured data from these sensors transmit main controller which is located in external location. Then the Integrating monitoring system is implemented and is performed the performance test to performing diagnosis of motors of a crane.

Development of Moving and Attaching Diagnosis Device Using IoT (IoT 활용 이동착탈식 열화 진단 장치 개발)

  • Ka, Chool-Hyun;Lee, Dong-Gyu;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.596-601
    • /
    • 2017
  • The advancement and diversification of urban functions has caused an increasing need to improve the reliability of power supplies. The diversification of urban areas causes social disruptions by paralyzing urban functions during power outages. A large power outage occurs in the event of an accident, owing to the subduction of distribution lines. Therefore, in recent years, for the sake of the environment and safety, the safety diagnosis of electric power facilities has become an important issue. In this system, because thermal information changes rapidly during unattended monitoring owing to heat concentration phenomenon due to abnormal load or deterioration, studies have been conducted on the development of a device that can notify the manager at all times.

Specialized Sensors and System Modeling for Safety-critical Application

  • Jeong, Taikyeong Ted
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.950-956
    • /
    • 2014
  • Special purpose sensor design using MEMS (Micro-Electro-Mechanical Systems) technique is commonly used in Nondestructive Testing (NDT) research for the evaluation of existing structures and for the safety control and requirements. Various sensors and network have been developed for general infrastructures as well as safety-critical applications, e.g., aerospace, defense, and nuclear system, etc. In this paper, one of sensor technique using Fiber Bragg Gratings (FBG) and Finite Element Method (FEM) evaluation is discussed. The experimental setup and data collection technique is also demonstrated. The factors influencing test result and the advantages/limitations of this technique are also reviewed using various methods.

A Research Trend on Multi-Agent Transformer Condition Monitoring System On-Line (변압기 상태의 온라인 감시 체계 구축에 대한 연구 동향)

  • Kim, Jung-Hoon;Yong, Hyung-Sik;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2006-2007
    • /
    • 2007
  • On-line condition monitoring is a useful tool for maintaining and extending the longevity of power transformers. An intelligent diagnostic system is desirable for operational safety and reliability. Bringing these concepts together results in a powerful support tool for engineers, reducing the volume of data to deal with, and making the data more meaningful. This paper describes how a multi-agent system for diagnosing the cause of transformer partial discharge activity was coupled with a method of UHF partial discharge monitoring, creating an on-line condition monitoring system. The challenges presented by the on-site environment are discussed, along with the implications for the complete system.

  • PDF

A study Improvement Direction for Arc Interruption Equipment and On-line Monitoring System of Consumer Low Voltage Facilities (수용가 저압 전기설비의 원격 감시시스템 및 아크차단 장치 활성화 방안에 관한 연구)

  • Kim, Gi-Hyun;Park, Chee-Hyun;Lim, Young-Bai;Choi, Myeong-Il;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • Domestic and foreign follows the trend which is that safety checkup of electrical facilities is serviced by on-line system with joining information technology. This paper research improvement of what kind of system and law for market environment of electric power value added service. For improvement of market environment of electric power value added service, this paper researches improvement of on-line monitoring system and necessity of arc interruption and revision of arc related law.

Implementation of Real-time Monitoring System for Marine Elevator using Smart Sensors (스마트 센서를 이용한 선박용 승강기 실시간 모니터링 시스템의 구현)

  • Lee, WooJin;Yim, JaeHong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.405-410
    • /
    • 2016
  • Elevator industry is a field that is mechanical, electrical and electronic technology and constantly requires inspection and maintenance considering various applications and various types. Recently, various elevator control and monitoring technologies with IT are developing for elevators on land. But technologies with IT have been hardly done in marine elevator that is consistently assured safety and reliability of life cycle for its parts in poor environment. In this paper, we implemented embedded main controller, floor controller and car controller that meet the requirements and use NMEA network protocol by analyzing home and abroad integrated elevator operation and management systems. Especially, we secured reliability of maintenance by real-time fault diagnosis and control that was implemented with limit switch, gyro sensor, temperature/humidity/barometric pressure sensor and fire detection sensor thinking over the environmental conditions of terrestrial and marine elevator.

Protective Insulation Monitoring Device in IT Earth Systems (IT접지방식의 보호를 위한 활선절연저항 감시기)

  • Kim, Yong-Jung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.209-213
    • /
    • 2015
  • With the increasing popularity of renewable generation systems and the advancement of power electronics, DC distribution systems have recently received considerable research attention. DC distribution has numerous advantages, including reliability, power quality, and efficiency. Owing to these advantages, DC distribution has been applied to data centers and power quality-sensitive electronic load conditions. Because grounding electrodes in DC are much more susceptible to corrosion than in AC, the IT system defined in IEC Standard 60364 may be a good candidate for an earthing method for DC distribution systems. In addition, IEC Standard 61557 specifies the requirements for insulation monitoring devices (IMD) for protection of the IT system, which continuously monitors the insulation resistances between the power lines and the earth. This paper discusses the development and evaluation of IMD to promote the reliability of distribution systems and increase safety of humans and facilities.

Realization of Information Visualization of Electric Power Monitoring System for MV/LV Distribution Customers

  • Kim Jae-Chul;Chu Cheol-Min;Knag Bong-Seok;Kim Yeong-Il;Choi Duck-Su;Kim Kwang-Soon;Ryu Seung-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.287-294
    • /
    • 2006
  • Recently, switchboards for MV/LV distribution customers have been united and digitalized rapidly. This paper proposes the effective information visualization method for the data measured from cubicle switchboards for MV/LV distribution customers. We developed the algorithm that analyzes abundant data measured by switchboards and displays them to overall users, such as fire information index, power condition index, switchboard safety index, and power diminution index. Using a touch screen made users to operate it easily. User interface was also improved by taking graphic visualization. We guess the information visualization method suggested in this paper shows the new direction that heavy electrical equipments including switchboards are going to develop in the future.