• Title/Summary/Keyword: Electrical safety

Search Result 4,859, Processing Time 0.043 seconds

Analysis of Properties of UV Corona on Insulator in Salt Water Environments (염수 환경 열화 상태를 모의한 절연애자의 자외선 코로나 특성 분석)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Lee, Myeong-Jun;Lee, Woo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1590-1591
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV camera. UV camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The UV camera was developed and measured using a UV image, as applied voltage increased ultraviolet images of the phenomenon could be obtained. And we investigated properties of UV corona image on insulator in salt water environments. From the results, the breakdown voltage was decreased and UV images were taken at low voltages and the UV image is rapidly increased with increasing High voltage.

  • PDF

Analysis of on-site conditions of grounding methods installed in new buildings (신축 건물에 시설된 접지방식의 현장 실태 분석)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2208-2209
    • /
    • 2008
  • 최근 국제 표준 및 규격의 국내 도입에 따라 다양한 접지 방식에 대한 안전성과 신뢰성이 요구되고 있으나, 현재 국내 규정은 국제 규격과 부합되지 않는 측면이 있다. 따라서, 국내 건축물의 접지시스템에 대한 정확한 현장 실태를 바탕으로 국내 실정에 맞는 접지시스템의 개발이 요구되고 있다. 본 논문에서는 아파트, 공장, 상가, 학교 등의 신축 건물에 시설된 접지방식 및 등전위 본딩 실태 등을 현장 조사를 중심으로 분석하였다. 접지실태조사는 접지방식, 접지단자의 접속방식, 공결방식, 접지요소간의 접속방식 등을 분석하였으며, 등전위 본딩 실태조사는 IEC 60364에 규정된 방법을 근거로 계통외 도전성 부분과 기기외함의 연속성을 평가하였다.

  • PDF

The Analysis of Structure Grounding Using Reduced Scale Model (축소모델을 이용한 구조체 접지 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Han, Woon-Ki;Lee, Ki-Yeon;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2046-2048
    • /
    • 2005
  • This paper deals with ground potential rise of structure grounding electrode when a test current flows through grounding electrode. In order to analyze the potential gradient of ground surface on structure grounding electrode, the reduced scale model has been used. The structures were designed through reducing real buildings and fabricated with four types on a scale of one-one hundred sixty. The supporter was made to put up with weight of structure and could move into vertical, horizontal, rotary direction. When a test current flowed through structure grounding electrodes, ground potential rise was the lowest value at electric cage type(type B). According to resistivity and absorption percentage in concrete attached to structure, the potential distribution of ground surface appeared differently.

  • PDF

Assessment System of Safety Level of High Voltage Electrical Facilities Considering Environmental Factors (환경영향 요소를 고려한 특고압 전기설비의 안전등급 평가시스템)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.249-254
    • /
    • 2017
  • This paper presents an assessment system of safety level of 22.9kV grade high voltage electrical facilities considering environmental factors. The assessment system was developed based on the following procedure. Firstly, assessment structure was determined by consulting standards regarding inspection and diagnosis of electrical facilities. Secondly, contents of items and sub items of assessment system were developed. Thirdly, in order to quantify the importance of the assessment system, the weight was calculated using Analytic Hierarchy Process(AHP). Lastly, assessment table of safety level was developed including environmental factors such as period of use and load factor. The developed system can evaluate the safety level of high voltage facilities in an objective way. Therefore it can be applicable to electrical safety management system based on Internet of Things(IoT).

The Study about Fire Judgment Method on Hair Dryer (모발건조기 화재 감정 기법에 관한 연구)

  • Moon, Hyun-Wook;Gil, Hyung-Jun;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2140-2141
    • /
    • 2011
  • 본 논문에서는 생활공간에서 발생하는 모발건조기로 인한 전기화재의 화재 감정 기법에 관하여 알아보았다. 모발건조기의 전원장치, 제어장치, 발열장치, 송풍장치 등의 구조분석과 화재 재현 실험을 통한 각 요소의 화제 위험성 분석으로 모발건조기의 화재 현장 조사 및 감정 포인트에 대해 알아보았다. 그래서 모발건조기에서 발생하는 전기 화재의 정확한 조사 및 감정을 통해 앞으로 일어날 수 있는 전기화재를 예방하고자 한다.

  • PDF

Determination method of auxiliary probe locations for measuring touch and step voltage of ground electrode (접지전극의 접촉전압 및 보폭전압 측정시 보조전극의 위치 결정 방법)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Moon, Hyun-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2128-2129
    • /
    • 2011
  • 본 논문에서는 접지전극의 접촉전압 및 보폭전압을 측정할 때 보조전극의 배치에 따른 특성을 분석하고, 이에 따른 시뮬레이션 분석을 수행하여 측정오차 감소를 위한 보조전극의 배치방법을 제시하고 자 한다.

  • PDF

Deterioration Pattern Analysis and Surface Leakage Current of Electrical Insulation in External Pollution (외부 오염 환경하에서 고분자 절연재료의 표면 누설전류 측정 및 열화 패턴 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2080-2081
    • /
    • 2007
  • In this paper, the polymer insulators which had been used for electrical insulation were investigated surface leakage current and deterioration pattern. Because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

The Analysis of Potential Distribution for Submerged Electrical Fittings in an Underground Shopping Street (지하상가 침수 시 전기설비 전위분포 해석)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2072-2073
    • /
    • 2007
  • This paper describes the analysis of potential distribution and leakage current magnitude around the electrical fittings submerged in an underground shopping street. In the experiment, a couple of electrical utilities(outlet, fluorescent lamp) were submerged in a concrete water bath. The experimental results are expected to be utilized for the risk assessment and the safety countermeasure against the electric shock.

  • PDF

An Influence of Electrical facilities Due to the Dust and Analysis about Domestic Regulations (분진에 의한 전기설비의 영향과 국내규정 분석)

  • Shong, Kil-Mok;Kim, Young-Seok;Jung, Jong-Wook;Jung, Jin-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.387-390
    • /
    • 2008
  • This study investigated the influence of electric facilities damaged by dusts and domestic regulations. Its contents included the around circumstance of electric facilities, regulations concerned with the dust, the actual conditions at the scene, the characteristics of dusts and so on. At the set-up the electric facilities, the around circumstances are bad in summer that highly temperature and many moisture. Besides, elements that are judged the corrosive vapours of the large quantity are detected at the sampled dusts. As the results, if dusts covered with electric facilities, It will be a cause for the electric accidents. From the analyzed data of the actual conditions and the sampled dusts, electric facilities maintenance for the viewpoint of the safety can be possible.

  • PDF

A Plan for Construction of the National Electrical Safety Grid to Prevent the Fires Caused by Electrical Faults (전기화재 예방을 위한 국가전기안전망 구축 방안)

  • Bae, Seok-Myeong;Jeon, Jeong-Chay;Park, Chan-Eom;Bae, Seok-Myeong;Ko, Won-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2267-2273
    • /
    • 2009
  • In this paper, in order to monitor and manage an electrical risk factor like as leakage current, load current, and arc-fault, a real time monitoring and management system being operated in the ubiquitous environment was developed, and a plan of construction of an electrical safety grid using the system was proposed. For confirmation of usefulness and reliability of the proposed safety system and grid, the developed intelligent panels were applied to 28 Korean traditional houses in Jeonjoo city, and the grid including the panels was operated. If the proposed National Electrical Safety Grid is completely constructed in the houses of general electrical users, the Grid will have an effect on that a main manager on electrical safety transfers from management system by general people to real-time management system by expert. As a result, the electrical fires caused by an over-load, an arc-fault, and an earth-fault will be prevented.