• Title/Summary/Keyword: Electrical safety

Search Result 4,892, Processing Time 0.035 seconds

The Analysis of Metallurgical Structure and Arc Properties of Copper Wire Due to Over-current (과전류에 의한 동 전선의 용단 아크 특성 및 금속조직 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Dong-Ook;Lee, Ki-Yeon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.554-555
    • /
    • 2005
  • In this paper, we analyzed a metallurgical structure and arc properties of copper wire when the over-current flows on electric wire. From the results, The fusing current was related to the fusing time(current rising rate per second). In case of the shorter the fusing time, the fusing current was high, and the fusing time of ac type was larger than that of dc type. The copper wire was bent by the increase of current and heated, the beads were scattered around wire with a flash. We could observed the dendrite structure in 'molten wire at ac and dc current type. According as the current rising rate per second is short, the dendrite structure is distributed in surface of wire.

  • PDF

An analysis of the state of operation of the electrical safety emergency dispatch system (전기안전 긴급출동제도 운영 실태 분석)

  • Yoo, Jae-Geun;Kim, Jae-Hyun;Lee, Ki-Sik;Koo, Kyung-Wan;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1748-1751
    • /
    • 2012
  • This paper describes the background of the electrical safety emergency dispatch system and analyzes the operational status of the system. This system is to provide the enhanced electrical safety service to general-purpose electrical equipment users. Annual average of about 6 million cases have been implemented since 2005. In order to enhance electrical safety service and more effectively prevent electrical disasters in future, institutional expansion of the electrical safety emergency dispatch system with keeping budget is necessary. If periodic inspections with a remote monitoring system is applied, the effect of electrical safety will be improved.

A Study on the Cutoff time and the Malfunction Current Characteristics of RCDs (누전차단기 동작시간 및 부동작 전류 특성)

  • Han, Woon-Ki;Shong, Gil-Mok;Kim, Yong-Seok;Kim, Dong-Wook;Choi, Chung-Seog;Lee, Bok-Yong;Park, Sang-Tae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.61-65
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCDs are employed at temporary power sites and electrical facilities on the road they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing improved advanced in their performance.

  • PDF

Analysis of Shielding Characteristics for Induction Phenomenon Attenuation of Large Capacity Wireless Power Transmission Environment (대용량 무선전력전송 환경 유도현상 감쇄를 위한 차폐 특성 분석)

  • Chae, Dong-Ju;Kim, Young-Seok;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo;Hong, Seong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1844-1851
    • /
    • 2017
  • As the capacity of the wireless power transmission increases, a higher supply current which may induce current in nearby conductive parts requires. Induced current may affect electric shock to the human body and malfunction of the electrical equipment. In order to prevent such induced phenomena as a risk factor, shielding is required between the source of the wireless power transmission and the conductive parts. The resonance frequency for the large capacity wireless power transmission has the wavelength of several hundred meters, so most environments are included in the near-field area. By wave impedance, the electric field has higher density in the near-field area and needs to be analyze for protecting. For this purpose, it is necessary to select a substance having a larger electric conductivity and optimized shielding structure. In this paper, an aluminum base shielding structure was presented to conduct experiments on thickness, position, and heat dissipation. In the 35 kW, 60 kHz environments, the optimized 5T Al base shielding structure attenuates the induced current to 43 %.

Experimental Studies on the Risk Assessment of Electrical Fire and Shock of LED Lighting for Outdoor (옥외용 LED 조명의 전기화재 및 감전 위험성 평가에 대한 실험적 고찰)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.77-97
    • /
    • 2011
  • In this paper, we studied risk assessments of electrical fire and shock of LED lightings for outdoor. We examined national regulations about the LED lighting for outdoor and analyzed the appearances and compositions of LED lightings. And, We experimented about water proof, line to line fault, line to line breakdowm, overvoltage, line to line leakage in overhead line or water of LED lighting. From experimental results, we know that there are risks of electrical fire and shock by abnormal conditions at the LED lighting. Therefore, the uses of protective devices and insulated type of converter are required for the electrical safety. We expect that the results of this study would be helpful for the improvement of regulations and standards for electrical safety and for the investigations of electrical accidents of LED lightings.

  • PDF

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.

On the Development of Preventive Electrical Safety Plan Using Operation Concept Document (시스템 운용 개념서 활용을 통한 예방적 전기안전 계획서 개발에 관한 연구)

  • Lee, Byoung-Gil;Lee, Jae-Chon;Shin, Heung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.73-81
    • /
    • 2008
  • The current electrical safety plan developed for the national electricity system has been playing an important role in handling a variety of electrical accidents. However, it can be more effective to prevent or reduce those accidents if a preventive electrical safety plan is available. In this paper, an approach to developing the safety plan is described. We first discuss the contents that should be included in the plan. Noting that an effective plan requires the system level consideration of all the factors affecting the safety issues, an operation concept document (OCD) is considered. The OCD can allow us to understand the behavior of the safety system based on the operation environment, the system functions, the performance requirements, all at the system level of the safety system. Thus, the OCD can be useful in developing the safety plan. A detailed description then follows on how the OCD is developed for the electrical safety system under study. Finally, we discuss how the developed OCD can be used in deriving the preventive electrical safety plan.

Study on the Electrical Safety Management Method through the Electrical Characteristic Analysis of LED Lamps (LED 램프의 특성 분석을 통한 전기안전 관리 방안에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bea;Ryu, In-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1931-1936
    • /
    • 2016
  • In this paper, we analyzed causes of accidents that recently increased in the illegal and defective LED lamps. They were analyzed by the electrical characteristics calculation and reappearance experiments. The causes of the accidents were analyzed from the circuit affected by the variation of voltage, current and power by harmonics. We drew a conclusion for electrical safety in illegal or degraded LED lamps from the analysis result. The management factors for electrical safety in LED lamps were harmonics, reactive power and power factor. It is possible to secure the electrical safety through monitoring of power factor in failure products and available in smart meters or smart distribution boards.

Electrical Strength Analysis of Toughened Glass Stem Insulator for Electric Railways (전기철도용 유리애자 전기적 강도 해석)

  • Jung, Jong-Wook;Jung, Jin-Soo;Kim, Young-Seok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.263-263
    • /
    • 2008
  • This paper describes the electrical strength of a toughened glass stem insulators employed for electric railways. The broken glass stem insulators for comparison were taken at site. According to the international standards, electrical strength tests with 60[Hz] voltage and with impulse voltage were carried out to them under dry and wet condition and the results were corrected by considering the temperature and humidity factors. Based on the experimental results, the electrical strength of broken glass stem insulators was compared with those of sound ones and surface flashover characteristics were also discussed. As a result, it was confirmed that the electrical discharge is formed by bridging each end of the insulator shell. The experimental results are expected to be utilized as data for electrically identifying the failure causes of glass insulators.

  • PDF

A Study on the Soil Resistivity and the Variation with Lapse of Time for Ground Rods (대지저항률과 접지극의 경년변화에 관한 연구)

  • Han, Ki-Boong;Choi, Chung-Seog;Kim, Sham-Su;Jung, Se-Joong;Lee, Sang-Ick
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1639-1641
    • /
    • 1999
  • This paper deals with the seasonal variation of soil resistivity and the special characteristic for ground rods by lapse of time. The ground resistance was changed by humidity, temperature of earth and earth resistance. In this experiment, we studied the resistivity during the period from June 1995 to May 1996 by the soil and the corrosion of the ground rods. As a result, the soil resistivity during the period are appeared minimum in summer and maximum in winter. The loss in weight of Fe rod appeared higher than Cu, Al, Cu-Zn, and St. In the lapse of time, Fe rod was reduced 1.2 % later two years and 1.95 % later three years in weight. Cu rod was defected oxygens of 14.7 % later two years and 30.3 % later three years by EDX.

  • PDF