• 제목/요약/키워드: Electrical power monitoring system

검색결과 723건 처리시간 0.034초

Measurement and Simulation of Wide-area Frequency in US Eastern Interconnected Power System

  • Kook, Kyung Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.472-477
    • /
    • 2013
  • An internet-based, real-time GPS synchronized wide-area power system frequency monitoring network(FNET) has been monitoring wide-area power system frequency in continuous time in the United States. This paper analyzes the FNET measurement to the verified disturbances in the US eastern interconnected power system and simulates it using the dynamic system model. By comparing the frequency measurements with its simulation results to the same disturbances in detail, this paper finds that the sequence of monitoring points to detect the frequency fluctuation caused by the disturbances is matched well in the measured data and the simulation results. The similarity comparison index is also proposed to quantify the similarity of the compared cases. The dynamic model based simulation result is expected to compensate for the lack of FNET measurement in its applications.

태양광 발전 시스템의 스마트 모니터링 기술개발 (A Development of Smart Monitoring Technique for Photovoltaic Power Systems)

  • 조현철;심광열
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.50-56
    • /
    • 2015
  • This paper presents a smart monitoring technique for photovoltaic power systems by using wire and wireless communication networks in which the RS-232/484 and the Zigbee communication networks are inherently established respectively. In the proposed monitoring systems, environmental data sequences and the output power measured by sensors in photovoltaic systems are transferred to PC systems via two communication networks. We made electronic hardware boards for sensors and communication networks to construct its real-time monitoring system and carry out experiments for demonstrating reliability of the proposed monitoring system.

지중 배전계통 적용을 위한 광복합 케이블 실시간 감시시스템 개선 (An Improvement of Optical Fiber Composite Power Cable On-Line Monitoring System for Underground Distribution Network)

  • 조진태;김주용;이학주;박중성
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.77-83
    • /
    • 2012
  • Since power system is switching to smart grid, on-line monitoring technology has become necessary for underground distribution power cable. Therefore, the application of DTS(Distributed Temperature Sensing) technology using OFCPC(Optical Fiber Composite Power Cable) capable of monitoring underground distribution power cables has been developed. These can bring about reductions in faults and increases in operating capacity of underground distribution system. To date, the test-bed of optical fiber composite power cable on-line monitoring system has been constructed. Then, matters to be improved have been drawn through verification experiments. This paper presents the improvement and experiment results of the optical fiber composite power cable on-line monitoring system to apply to underground distribution lines in the field.

태양광발전설비와 연계한 지능형 경관조명 전력제어 및 모니터링 시스템의 개발 (Development of Intelligent Landscape Lighting Power Control and Monitoring System with Solar Cell Generator Equipment)

  • 김동완;박성원;김형수
    • 전기학회논문지P
    • /
    • 제60권2호
    • /
    • pp.99-104
    • /
    • 2011
  • In this paper, the intelligent landscape lighting power control and monitoring system with solar sell generator equipment is proposed. The first, the intelligent landscape lighting power controller is designed using the fuzzy logic control method. And the fuzzy logic controller is used to save power consumption for various reference intensity of the illumination. The second, the GUI monitoring system is presented. It has control and display faculty. And the practical experiment device is used to evaluate the performance criteria of the proposed intelligent landscape lighting power control system with the solar cell power generation equipment. From the experiment results, we present the property of proposed fuzzy controller such as steady state error, the tracking and power consumption characteristic for the reference intensity of illumination. And also we show the superiority of power control as well as the characteristic of GUI monitoring system in the proposed system.

Power Quality Monitoring System with a New Distributed Monitoring Structure

  • Won, Dong-Jun;Chung, Il-Yop;Kim, Joong-Moon;Ahn, Seon-Ju;Moon, Seung-Il;Seo, Jang-Cheol;Choe, Jong-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.214-220
    • /
    • 2004
  • Power quality monitoring is the cornerstone for power quality analysis, diagnosis and improvement. The measurement of power quality (PQ) evolves from instantaneous metering to continuous monitoring. Furthermore, recent technologies enable us to construct more flexible, reliable, rapid and economical power quality monitoring system (PQMS). Therefore, this paper presents an improved PQMS with a new distributed monitoring structure. The proposed PQMS consists of a PQ meter, PQ analyzer and GUI. The PQ meter only collects raw data and the PQ analyzer performs power quality analysis. It has several advantages compared to conventional structures in economic efficiency, modularity, speed, etc. PQ monitoring algorithms to catch steady-state trends and to detect PQ events are also adapted to the proposed structure. Using the proposed structure and monitoring algorithm, a prototype PQMS is constructed and real-time testing is performed.

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

NMEA 2000 프로토콜을 적용한 선박 전력 컨버터 모니터링 시스템에 관한 연구 (A Study of NMEA 2000 Protocol Application for Ship Electrical Power Converter Monitoring System)

  • 홍지태;박동현;유영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.288-294
    • /
    • 2011
  • 본 논문에서는 FPGA기반의 SoC보드(Xilinx Virtex-4 ML401 EVM)를 이용한 전력인버터제어시스템을 설계하였다. 선박에 전력시스템을 적용하기 위해서 선박의 최신 통신 프로토콜인 NMEA 2000 표준 프로토콜을 적용하였으며 전력 시스템의 성능을 평가하기 위한 PC기반의 모니터링 프로그램을 제작하였다. 전력 제어시스템은 FPGA기반의 임베디드 SoC보드상에서 이중프로세서(Dualprocessor)형태로 설계하였으며 이중프로세서를 적용함으로써 실시간 제어 감시가 가능하다. 이중프로세서 중 하나는 전력 제어를 위한 PWM신호생성 및 전력 회로내의 주요 전력 파라미터를 센싱 하는 제어용 프로세서로 동작하며(Control processor) 다른 프로세서는 제어프로세서의 각종 전력 센서 파라미터와 제어 파라미터들을 이중포트 램(Dual Port RAM)을 이용하여 정보를 공유하고 외부 NMEA 2000프로토콜 기반의 모니터링 장치와 네트워크 기반의 통신을 수행하는 통신용 프로세서(Communication processor)로 구성된다. 본 논문에서 제작한 전력 제어시스템은 선박내의 분산발전,송배전 및 전압 레귤레이션 시스템에 적용 될 수 있다.

LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법 (The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW)

  • 김대년;김덕현;최정원
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.

모니터 기능을 갖는 통신기기용 전원 시스템 (Power supply system of the telecommunication equipment with monitoring function)

  • 이중기;김영태;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.309-311
    • /
    • 1995
  • Recently, a power supply system of the telecommunication equipments with monitoring function has been widely studied. In the power supply system which is apart from the central station, it is required to check and test the operating states of the system at the central station. In this paper, the power supply system with monitoring function is discussed. In the system, the Full-Bridge converter is designed as a power supply and it has the ratings of DC 280-340V input and DC 48V, 480W output. And the monitoring part of the system is composed of a voltage and current sensing unit A/D converter, I/O card, and a personal computer. The operating states of the system is monitored by checking the voltage and current variation at input and output, and it is represented by graphical modes. By conducting the experiment, it is confirmed that the operating states of the system is well monitored.

  • PDF

FCM과 ELM을 이용한 전력용 변압기의 모니터링 알고리즘 (A Monitoring Algorithm using FCM and ELM for Power Transformer)

  • 지평식;임재윤
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.228-233
    • /
    • 2012
  • In power system, substation facilities have become too complex and larger according to an extended power system. Also, customers require the high quality of electrical power system. However, some facilities become old and often break down unexpectedly. The unexpected failure may cause a break in power system and loss of profits. Therefore it is important to prevent abrupt faults by monitoring the condition of power systems. Among the various power facilities, power transformers play an important role in the transmission and distribution systems. In this research, we develop intelligent diagnosis technique for monitoring of power transformer by FCM(Fuzzy c-means) and ELM(Extreme Learning Machine). The proposed technique make it possible to diagnosis the faults occurred in transformer. To demonstrate the validity of proposed method, various experiments are performed and their results are presented.