• Title/Summary/Keyword: Electrical machines

검색결과 944건 처리시간 0.026초

A Fast Contingency Screening Algorithm for On-line Transient Security Assessment Based on Stability Index

  • Nam, Hae-Kon;Kim, Yong-Hak;Song, Sung-Geun;Kim, Yong-Gu
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권4호
    • /
    • pp.131-135
    • /
    • 2002
  • This paper describes a new ultra-fast contingency screening algorithm for on-line TSA without time simulation. All machines are represented in a classical model and the stability index is defined as the ratio between acceleration power during a fault and deceleration power after clearing the fault. Critical clustering of machines is done based on the stability index, and the power-angle curve of the critical machines is drawn assuming that the angles of the critical machines increase uniformly, while those of the non-critical ones remain constant. Finally, the critical clearing time (CCT) is computed using the power-angle curve. The proposed algorithm is tested on the KEPCO system comprised of 900-bus and 230-machines. The CCT values computed with the screening algorithm are in good agreement with those computed using the detailed model and the SIME method. The computation time for screening about 270 contingencies is 17 seconds with 1.2 GHz PC.

Inductances Evaluation of a Squirrel-Cage Induction Motor with Curved Dynamic Eccentricity

  • Lv, Qiang;Bao, Xiaohua;He, Yigang;Fang, Yong;Cheng, Xiaowei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1623-1631
    • /
    • 2014
  • Eccentricity faults more or less exist in all rotating electrical machines. This paper establishes a more precise model of dynamic eccentricity (DE) in electrical machines named as curved dynamic eccentricity. It is a kind of axial unequal eccentricity which has not been investigated in detail so far but occurs in large electrical machines. The inductances of a large three-phase squirrel-cage induction machine (SCIM) under different levels of curved DE conditions are evaluated using winding function approach (WFA). These inductances include the stator self and mutual inductances, rotor self and mutual inductances, and mutual inductances between stator phases and rotor loops. A comparison is made between the calculation results under curved DE and the corresponding pure DE conditions. It indicates that the eccentricity condition will be more terrible than the monitored eccentricity based on the conventional pure DE model.

An Improved Global Maximum Power Point Tracking Scheme under Partial Shading Conditions

  • Kim, Rae-Young;Kim, Jun-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.65-68
    • /
    • 2013
  • A photovoltaic array exhibits several local and single global maximum power points under partial shading conditions. To track the global maximum power point precisely, a novel global maximum power point tracking scheme is proposed in this paper. In the proposed scheme, robustness of the tracking performance has been improved by enhancing searching profile. In addition, the paper addresses the tracking failure condition, and provides the experimental verification with several simulation and experimental results.

단상 LSPM의 열해석 모델링 및 특성 해석 (Thermal modeling and analysis of single phase LSPM)

  • 함상환
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.411-416
    • /
    • 2015
  • This paper presents the thermal modeling and analysis of Line power Start Permanent magnet Motor (LSPM). Thermal analysis of electrical machines is important because temperatures that are consistently too high will reduce the life time of machines and may lead to serious failure. Coefficients of convection are calculated according to the types of operating conditions. And computational fluid dynamics (CFD) technique is performed in order to predict thermal characteristic. The results are compared to the test results.

회전기에 의한 소음 제거를 위한 능동 소음 제어 - 3차원 공간의 경우 (Active control of noise induced by rotating machines - A 3-dimensional enclosure case)

  • 남현도;안동준;이호석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.290-292
    • /
    • 1993
  • In this paper, analysis of the noise induced by rotating machines and the mode analysis of a 3-dimensional enclosure are presented. Adaptive active noise control algorithms for the multi-channel case are proposed. Computer simulations were done to show usefulness of the designed algorithm in a 3-dimensional enclosure case.

  • PDF

고압 회전기 On-line 부분방전 측정용 Ceramic Coupler 특성 (Characteristics of Ceramic Coupler for On-line Partial Discharge Measurement in High Voltage Rotating Machines)

  • 강동식;윤대희;김용주;이홍식;윤영호;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.204-212
    • /
    • 2002
  • In order to improve the reliability of high voltage rotating machines, it is necessary to understand the breakdown mechanism of stator windings. Especially partial discharge(PD) inception and growth are important in stator winding insulation. Recently, many research on the diagnosis of stator winding insulation for large rotating machines have been developed since the 1970s. Capacitive couplers have been the most widely used sensor for on-line partial discharge detection in rotating machines. This paper deals with the electrical on-line monitor characteristics of ceramic coupler(CC) which has been developed to continuously measure the PD activity in operating high voltage motor stator windings on site. We investigated the electrical characteristics(PD quantity, breakdown voltage and frequency response) to develop CC. This paper presents frequency characteristics and laboratory test result to compare conventional 80([F] epoxy-mica coupler(EMC) and 105[pF] CC for PD measurement with 6.6㎸ model stator windings.

초고속 영구자석형 동기 전동기의 회전자 손실 특성해석 (Characteristic Analysis of Rotor Losses in High-Speed Permanent Magnet Synchronous Motor)

  • 장석명;조한욱;이성호;양현섭
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권3호
    • /
    • pp.143-151
    • /
    • 2004
  • High-speed permanent magnet machines are likely to be a key technology for electric drives and motion control systems for many applications, since they are conductive to high efficiency, high power density, small size and low weight. In high-speed machines, the permanent magnets are often contained within a retaining sleeve. However, the sleeve and the magnets are exposed to high order flux harmonics, which cause parasitic eddy current losses. Rotor losses of high-speed machines are of great importance especially in high-speed applications, because losses heat the rotor, which is often very compact construction and thereby difficult to cool. This causes a danger of demagnetization of the NdFeB permanent magnets. Therefore, special attention should be paid to the prediction of the rotor losses. This paper is concerned with the rotor losses in permanent magnet high-speed machines that are caused by permeance variation due to stator slotting. First, the flux harmonics are determined by double Fourier analysis of the normal flux density data over the rotor surface. And then, the rectilinear model was used to calculate rotor losses in permanent magnet machines. Finally, Poynting vector have been used to investigate the rotor eddy current losses of high-speed Permanent magnet machine.

주방 기기 안전 기준 관련 법령 및 규격 조사 (Investigation of Laws and Standards related to Safety Criteria for Commercial Kitchen Machines)

  • 기도형;송영웅;김영호
    • 대한안전경영과학회지
    • /
    • 제19권2호
    • /
    • pp.81-93
    • /
    • 2017
  • This study aims to investigate laws and standards(including technical guidelines) related to safety criteria for 22 kitchen machines frequently used in commercial kitchens. The study was based on literature survey, interviews with charge persons in kitchen machines manufacturing companies, cafeteria providing group meals and relevant association, and web surfing. The results showed that there are two types of safety criteria such as legally forced ones by laws and optional ones by national industrial standards or technical guidelines. High pressure safety control act, safety control and business of liquefied petroleum gas act and city gas business act prescribed gas use apparatus safety criteria, rational energy utilization act did those of pressure vessel such large rotary caldron, industrial health and safety act did those of food processing machinery, and electrical appliances safety control act did those of electrical kitchen appliances. Compulsory or optional standards or guidelines related to safety criteria for kitchen machines were presented by 22 kitchen machines. Safety devices shown in the laws, standards and guidelines were also summarized by kitchen machines and their risk factors.

영구자석/전자석을 갖는 릴럭턴스 타입 기기의 전자기적 특성 해석 (Electromagnetic Analysis of Reluctance Type Machines with Permanent Magnet/Electromagnet)

  • 장석명;박지훈;최장영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.80-82
    • /
    • 2006
  • This paper deals with electormagnetic analysis of reluctance type machines with permanent magnet/electromagn et. First, we calculated flux density of relucta nce type machines with permanent magnet/electromagnet according to position. Second, analyzed normal force and horizontal force from flux density of machine according to position. Also, analysis result compares with data that is derived through a finite element analysis (FEA), and proved validity.

  • PDF