• 제목/요약/키워드: Electrical leakage

검색결과 2,225건 처리시간 0.035초

흡습된 수냉각 발전기 고정자 권선의 전기적 특성 (Electrical Properties of Wet Bars in Water-cooled Generator Stator Windings)

  • 김병래;김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.817-823
    • /
    • 2012
  • Insulation breakdown of water-cooled generator stator windings occurs frequently due to leakage of cooling water and absorption into the insulation material. Leakage and absorption problems of water-cooled stator windings are often found during regular preventive maintenance. To evaluate cooling water leakage and absorption, diagnostic tests were performed on two water-cooled turbine generators, which have been in service for 13 and 17 years, respectively. The test results of the measured electrical properties such as dissipation factor($tan{\delta}$), capacitance and AC leakage current for water-cooled generator stator windings with wet bars are reported in this paper.

새로운 저항성 누전전류 검출회로 및 누전차단제어기 개발 (New Algorithm for Measuring Resistive Leakage Current and Development of ELB Controller)

  • 함승진;한송엽;고창섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-134
    • /
    • 2007
  • The conventional method used low pass filter for computing resistive leakage current from total leakage current. Therefore, it takes long time for computation. In this paper, a new algorithm is proposed to reduce the computation time. In the theory, the resistive leakage current is computed exactly from the signals during only a half period of power voltage. The suggested method uses integrator and sample-hold circuit and it is confirmed to be able to measure the resistive leakage current from total leakage current by simulation.

  • PDF

주위 환경 변화 따른 폴리머 절연재료의 표면 누설전류 (The Study of Leakage Current Distributions of Plymeric Insulators will Changing Environment)

  • 이병성;한재홍;김주용;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.88-91
    • /
    • 2001
  • Our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate leakage current patterns caused by surface aging on polymeric insulators, we utilized the combined aging test facility and leakage current monitoring system. And we get the continuous leakage current values from each sample. After completing the 3000h combined aging cycle test, leakage current measurement were conducted for these samples and carried out harmonics analysis for its data.

  • PDF

저항성 누전전류에 의하여 동작하는 새로운 누전차단기 (The New Residual Current Protective Devices Operating by Resistive Leakage Current)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

다결정 실리콘 박막트랜지스터의 누설전류 해석 (Analysis of the Leakage Current in Poly Si TFTs)

  • 이인찬;마대영;김상헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.801-802
    • /
    • 1992
  • Poly Si TFTs have been fabricated from low temperature annealed a-Si films. I-V and C-V characteristics in the off-state region were measured. Analytical model for the leakage current in the off-state was suggested. In the measurement, capacitance increased abruptly with Increasing gate and drain voltage. This phenomena is attributed to the leakage current.

  • PDF

3차원 적분법을 이용한 변류기의 자계해석과 누설 인덕턴스에 대한 연구 (A Study on the Magnetic Field Analysis and Leakage Inductance in Current Transformers by 3D Integral Methods)

  • 이희갑;박용필
    • 한국전기전자재료학회논문지
    • /
    • 제14권9호
    • /
    • pp.768-772
    • /
    • 2001
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, ti confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances L$\sub$r1/ and L$\sub$r2/ of the primary and secondary winding were calculated, their values are 4.23 MH and 0.49 mH, respectively. They are also similar to the measured values of he leakage inductances of the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

저압전기기기의 보호를 위한 전류동작형 누전차단기의 특성에 관한 연구 (The Study on the Characteristics of Leakage Circuit Breakers in Protection of the Low Voltage Electrical Apparatus)

  • 김은배;오철수
    • 전기의세계
    • /
    • 제25권4호
    • /
    • pp.59-62
    • /
    • 1976
  • This study on the characteristics of the leakage circuit breakers handles the rolls of each itemized parts of the mentioned apparatus and their influence in determining of the characteristic curve of leakage circuit breaker. Furthermore the differential current transforms in the mentioned apparatus for detecting the fault is handled as a heavy point.

  • PDF

Investigation on Flashover Development Mechanism of Polymeric Insulators by Time Frequency Analysis

  • Muniraj, C.;Krishnamoorthi, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1503-1511
    • /
    • 2013
  • This paper deals with the analysis of leakage current characteristics of silicone rubber insulator in order to develop a new condition monitoring tool to identify the flashover of outdoor insulators. In this work, laboratory based pollution performance tests are carried out on silicone rubber insulator under ac voltage at different pollution levels and relative humidity conditions with sodium chloride (NaCl) as a contaminant. Min-Norm spectral analysis is adopted to calculate the higher order harmonics and Signal Noise Ratio (SNR). Choi-Williams Distribution (CWD) function is employed to understand the time frequency characteristics of the leakage current signal. Reported results on silicone rubber insulators show that the flashover development process of outdoor polymer insulators could be identified from the higher order harmonics and signal noise ratio values of leakage current signals.

Client Collaboration for Power and Interference Reduction in Wireless Cellular Communication

  • Nam, Hyungju;Jung, Minchae;Hwang, Kyuho;Choi, Sooyong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제1권2호
    • /
    • pp.117-124
    • /
    • 2012
  • A client collaboration (CC) system is proposed for a user relay system. The proposed scheme focuses on the management of transmit power and leakage interference. In the proposed CC system, edge users transmit signals to the masters considered as user relays. The masters relay the signals of the edge users to the base station using the resource blocks (RBs) that are assigned to the edge users. The leakage interference and power consumption were analyzed in the CC system. In addition, an optimal master location problem was formulated based on the signal-to-leakage-plus-noise ratio (SLNR). Because the optimal master location problem is quite complex, a sub-optimal master location problem was proposed and a closed-form sub-optimal master location was obtained. The edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC. The numerical results showed that the edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC, and the average throughput increases.

  • PDF

Thrust Analysis and Experiments on Low-Speed Single-Sided Linear Induction Motor

  • Jeong, Jae-Hoon;Choi, Jang-Young;Sung, So-Young;Park, Jong-Won;Lim, Jaewon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.230-235
    • /
    • 2017
  • When the characteristics of a linear induction motor (LIM) are analyzed using finite element analysis (FEA), it is desirable to set the voltage source as an input. If the voltage source is set as an input in FEA, the leakage inductance and primary resistance of the equivalent circuit must be entered by direct calculation, and the magnetizing inductance and secondary reaction effects are directly considered in FEA. Exact calculation is necessary because the primary winding resistance and leakage inductance directly entered will have a significant effect on the LIM output. Therefore, in this study, we accurately calculated the primary leakage inductance and analyzed the resulting LIM characteristics. We calculated the leakage inductance using an analytical equation and FEA, and we confirmed the accuracy by comparing the results with the value experimentally calculated using a manufactured model. We also analyzed the instrument performance and thrust of the LIM as a function of the difference in the leakage inductance. Finally, we present the conclusions on the precise analysis based on the calculation of the leakage inductance.