• Title/Summary/Keyword: Electrical impedance analysis

Search Result 658, Processing Time 0.027 seconds

A Frequency-dependent Single Cell Impedance Analysis Chip for Applications to Cancer Cell and Normal Cell Discrimination (주파수에 따른 단일세포의 임피던스 분석칩 및 암세포와 정상세포의 구별에의 적용)

  • Chang, YoonHee;Kim, Min-Ji;Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1671-1674
    • /
    • 2014
  • This paper presents a frequency-dependent cell impedance analysis chip for use in cancer and normal cell discrimination. The previous cell impedance analysis chips for flowing cells cannot allow enough time for cell-to-electrode contact to monitor frequency-dependent impedance response. Another type of the previous cell impedance analysis chips for the cells clamped by membranes need complex sample control for making stable cell-to-electrode contact. We present a new impedance analysis chip using the microchamber array, on which a PDMS cover is placed to make stable cell-to-electrode contact for the individual cell trapped in each microchamber; thus achieving frequency-dependent single-cell impedance analysis without complex sample control. Compared to the normal cells, the magnitude of NHBE cells is $60.07{\sim}97.41k{\Omega}$ higher than A549 cells in the frequency range of 95.6 kHz~2MHz and the phase of NHBE is $3.96^{\circ}{\sim}20.8^{\circ}$ higher than A549 cells in the frequency range of 4.37 kHz~2MHz, respectively. It is demonstrated experimentally that the impedance analysis chip performs frequency-dependent cell impedance analysis by making stable cell-to-electrode contact with simple sample control; thereby applicable to the normal cell and cancer cell discrimination.

The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current (인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석)

  • Kim, Jae-Hyun;Lim, Young-Bea;Lee, Sang-Ick;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid (접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

Electric Properties of LB Films using Impedance Analysis of Quartz Crystal (수정진동자의 임피던스 해석에 의한 LB막의 전기적 특성)

  • Jin, Cheol-Nam;Kim, Gyeong-Hwan;Yu, Seung-Yeop;Gwon, Yeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.503-507
    • /
    • 1999
  • Quartz crystal in contact with viscoelastic medium was described directly in terms of the electrical equivalent circuit of the system. Stearic acid was used as viscoelastic medium and deposited on the surface of quartz crystal using the Langmuir-Blodgett(LB) method. Impedance properties of quartz crystal coated with LB films which were investigated by using admittance diagram and $Ζ-\theta$ plot a method of impedance analysis. When stearic acid LB film was deposited on the surface of quartz crystal, resonant frequency of quartz crystal was changed about 100 Hz/layer. This result illustrates the ability of the sensor system to detect small amounts of special gas in air.

  • PDF

Analysis of Electrical Characteristics for Single Crystalline and Poly-crystalline Solar Cell (단결정, 다결정 실리콘 태양전지의 전기적 특성 분석)

  • Hong, Chang-Woo;Choi, Yong-Sung;Lee, Kyung-Sup;Cho, Soo-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.9
    • /
    • pp.744-749
    • /
    • 2011
  • Recently, annual usage of energy is dramatically increasing because industrialization is going faster and more electricity is needed due to various electronic devices. This study focused on the performance characteristics of solar cell using the impedance technique. The experiment measured an impedance according to frequency's from 2 mHz until 1 MHz. It could know that the impedance was decreased according to the frequency increases in solar cell. The imaginary part was changed from capacitance component to inductance component.

Analysis for the Grounding Impedance of Vertical Grounding Electrodes using the Distributed Parameter Circuit Model (분포정수회로모델을 이용한 수직 접지전극의 접지임피던스의 분석)

  • Lee, Bok-Hee;Kim, Jong-Ho;Choi, Jong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1103-1108
    • /
    • 2010
  • A grounding electrode has the transient grounding impedance characteristics against lightning surges. So the performance of grounding electrodes should be evaluated as a grounding impedance as well as the ground resistance. The frequency-dependent grounding impedance is varied with the shape and size of grounding electrode and is divided into both inductive and capacitive behaviors. This paper presents a theoretical analysis for the grounding impedance determined by the size of grounding electrode using the distributed parameter circuit model. EMTP and Matlab programs were used in calculating the frequency-dependent grounding impedances of vertical grounding electrodes. It was found that the frequency-dependent grounding characteristics of vertical grounding electrodes are characterized by the distributed parameters which are changed in the dimension of grounding electrodes.

Finite element analysis of piezoelectric structures incorporating shunt damping (압전 션트 감쇠된 구조물의 유한요소해석)

  • 김재환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.470-477
    • /
    • 2002
  • Possibility of passive piezoelectric damping based on a new shunting parameter estimation method is studied using finite element analysis. The adopted tuning method is based electrical impedance that is found at piezoelectric device and the optimal criterion for maximizing dissipated energy at the shunt circuit. Full three dimensional finite element model is used for piezoelectric devices with cantilever plate structure and shunt electronic circuit is taken into account in the model. Electrical impedance is calculated at the piezoelectric device, which represents the structural behavior in terms of electrical field, and equivalent electrical circuit parameters for the first mode are extracted using PRAP (Piezoelectric Resonance Analysis Program). After the shunt circuit is connected to the equivalent circuit for the first mode, the shunt parameters are optimally decided based on the maximizing dissipated energy criterion. Since this tuning method is based on electrical impedance calculated at piezoelectric device, multi-mode passive piezoelectric damping can be implemented for arbitrary shaped structures.

  • PDF

Comparative Analysis on Ground Impedance for a Carbon Block and a Copper Rod (탄소블록과 동봉의 접지임피던스 비교 분석)

  • Seo, Jae-Suk;Park, Hee-Chul;Kil, Gyung-Suk;Oh, Jae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.472-477
    • /
    • 2013
  • This paper carried out the comparative analysis on ground impedance of a carbon block and a copper rod. Two types of grounding electrode were compared ; a carbon block (L : 1 m, ${\Phi}$ : 245 mm) buried at a depth of 0.8 m and a three-linked copper rod (L : 1 m, ${\Phi}$ : 10 mm) of equilateral triangles with 1 m spacing. Ground impedance depending on applied current source was evaluated by the application of a sine wave current with 60 Hz ~ 3.5 MHz, a fast-rise pulse with rising time of 200 ns, a standard lightning impulse of $8/20{\mu}s$ and a 600 Hz square wave. Ground impedance for both electrodes were almost the same value below 100 kHz, and increased rapidly afterwards. The maximum ground impedance appeared $400{\Omega}$ at around 1.5 MHz. Ground impedance of the carbon block was lower at the square wave and was higher at fast-rise pulse than that of the copper rod. Also, ground impedance as ages showed no difference for the last 8 months. From the results, it is likely that ground performance for both electrodes shows no difference against commercial frequency and lightning impulse current, while the copper rod shows better performance against a fast-rise pulse with rise-time of a few hundred ns.

Impedance Characteristics of N2 Plasma and Matching Circuit Design (질소 플라즈마의 임피이던스 특성 및 정합회로 설계)

  • 황기웅;김원규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.12
    • /
    • pp.560-566
    • /
    • 1986
  • In the design of an RF discharge system, the electrical equivalence of the gas discharge must be known. With this knowledge, one can design a suitable matching network for a maximum power transfer from the RF generator into the discharge. For this purpose, an experiment has been conducted in which the electrical impedance (conductance and capacitance) was determined as a function of power. In parallel with this, a detailed theoretical analysis has been done and the results are in accord with those of our experiment. Design equations are also given for a simple matching network, and a design example is presented to demonstrate its application. During the actual operation of an RF discharge system, however, it has been often observed that the reflected power tends to vary in small values due to the changes in the impedance of the system. This problem can be relieved by adding an automatic impedance matching circuit to the system and this paper presents such an automatic impedance matching network.

  • PDF

Impedance spectrosocpy depending on temperature in Organic Light-Emitting Diodes (온도에 따른 유기발광소자의 임피던스 분석)

  • Ahn, Joon-Ho;Chung, Dong-Hoe;Jang, Kyung-Uk;Song, Min-Jong;Lee, Sung-Il;Lee, Joon-Ung;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.543-546
    • /
    • 2004
  • Bias and frequency-dependent impedance is a technique for the investigation of complex conductivity. At low frequency, complex impedance is dominated by resistive component, and at high frequency by capacitive component. We are going to present the results of the bias and frequency-dependent complex impedance in the device structure of $ITO/Alq_3/Al$ in the temperature range between 10K and 300k. And we will show to change radius of Cole-Cole plot. It will be decrease resistance by temperature. Also equivalent electrical circuit and dielectric relaxation can be accomplished by using the complex impedance analysis.

  • PDF