• Title/Summary/Keyword: Electrical fires

Search Result 186, Processing Time 0.02 seconds

Tracking Propagation Mechanism on the Surface of Polyvinyl-Chloride-Sheathed Flat Cord based on Electric Field Analysis and Gas Discharge Physics (전계해석과 기체방전 이론을 기반으로 한 Polyvinyl-Chloride-Sheathed Flat Cord 표면의 트래킹 진전 메커니즘)

  • Lim, Dong-Young;Park, Herie;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.30-38
    • /
    • 2019
  • Tracking, which is one of the main causes of electrical fires, is perceived as a physical phenomenon of electrical discharge. Hence tracking should be explained based on electric field analysis, conduction path by electron generation, and gas discharge physics. However, few papers have considered these details. This paper proposes a tracking mechanism including their effects on tracking progress. In order to prove this mechanism, a tracking experiment, an electric field analysis for the carbonization evolution model, and an explanation of the tracking process by gas discharge physics were conducted. From the tracking experiment, the current waveforms were measured at each stage of the tracking progress from corona discharge to tracking breakdown. The electric field analysis was carried out in order to determine the electric field on the surface of a dry-band and the high electric field region for electron generation during the generation and progress of carbonization. In this paper, the proposed tracking mechanism consisted of six stages including electron avalanche by corona discharge, accumulation of positive ions, expansion of electron avalanche, secondary electron emission avalanche, streamer, and tracking by conductive path. The pulse current waveforms measured in the tracking experiment can be explained by the proposed tracking mechanism. The results of this study will be used as the technical data to detect tracking phenomenon, which is the cause of electric fire, and to improve the proof tracking index.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

Detection Technique and Device of Series Arcing Phenomena (직렬아크현상의 검출기술 및 장치)

  • Ji, Hong-Keun;Jung, Kwang-Suk;Park, Dae-Won;Kil, Gyung-Suk;Seo, Dong-Hoan;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.332-338
    • /
    • 2010
  • Annually, electrical fires caused by arcing phenomena in power system rapidly increase as the use of more electric appliances, but there is no established method for the prevention of the accidents. With this background, this paper dealt with the experimental results on a series arc detection technique and a device for air conditioners. Series arcing phenomena that is generated in incomplete connection of air conditioners was simulated, and the frequency spectrum was analyzed. The Fast Fourier Transform (FFT) of the arc pulse showed that the dominant frequency components exist in ranges of 190 kHz~250 kHz and 900 kHz~1.6 MHz. An arc detection circuit with low cut off frequency of 170 kHz to attenuate 60 Hz by 170 dB and a signal discriminator were designed. Also, an algorithm which separate series arc signal from unwanted noises produced by switching operation, inverter, and surge was proposed. Application experiment was carried out on several types of air-conditioners by using the arc generator specified in UL1699, and the results showed the over 99 % accuracy.

Study of the Tracking Fire Risk by Dust Resistivity of Pens (축사별 먼지 저항률에 따른 트래킹화재 위험성에 관한 연구)

  • Park, Kwang-Muk;Bang, Sun-Bae;Kim, Jae-Hyun;Park, Jin-Yeong
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.99-104
    • /
    • 2016
  • In animal and plant facilities, dust samples were collected from cattle sheds, pigsties and hen-houses, which have high proportion of electrical fires. The samples were diluted in distilled water and water resistivity was measured. Current measurements and tracking reappearance experiments were conducted using distilled water with dust samples. The analysis results were obtained to track the fire risks according to the dust resistivity. The highest value was the dust from cattle sheds followed in order by the dust of pigsties and hen-houses. In experiments measuring the temperature change and RMS current, the lower resistivity of water showed a significant trend of temperature and high amperage. In the tracking reappearance experiment with the lower resistivity water, the tracking speed was fast and the ignition time was shortened. This study investigated why each dust resistivity shows different results.

Effect of Harmonic Generation and Countermeasures (고조파발생에 따른 영향과 대책 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.91-97
    • /
    • 2015
  • Skyscrapers, large business buildings, and IT consumers use many appliances, and the electrical power stems can cause fires by overheating. This can result in damaged capacitors, lost data, rising ground potential, and communication obstacles from linear or nonlinear high frequency. To make sure of that we investigated 7 spots of a building, among which 6-spots were fair but the other one needed high frequency control. Spots 3, 6, and 7 needed diagnostic workup, and spots 2, 3, and 5 considered 5 high frequency currents. A phase is all of good but the high frequency current is greater than the standard level except for spot 1. As a result, a zigzag transformer or active filter needs to be installed, and the efficiency needs to be upgraded by investigating load unbalance factors and power factors.

Real-time Remote Monitoring System of Chemical Accident Response based on Multi-hop Communication (멀티 홉 통신을 기반한 화학 사고 대응 실시간 원격 모니터링 시스템)

  • Lee, Seung-Chul;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1706-1712
    • /
    • 2022
  • Recently, the safety of chemical substances has gained attention due to incidents occurring in petrochemical industrial complexes, such as gas leaks and fires. In particular, industrial complexes in Ulsan and Yeosu (South Korea) are valuable as they significantly contribute to the petrochemical industry, but accidents may occur due to chemical leakage. Therefore, in this study, sensor nodes are configured at an interval of 20 [m] based on outdoor facilities standards to respond to chemical accidents, and exposure consideration of 8 h (TWA) and 15 min (STEL) are proposed in TLVs. The proposed system pre-processes data collected in multi-hop communication at a cycle of 0.6-0.75 [s] using Python and stores it in the MySQL database through SQL and a real-time remote monitoring system that updates the stored data once every 5 s is implemented by linking MySQL and Grafana.

A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent (노후화된 누전차단기의 과전류 동작 특성에 관한 연구)

  • Ye Jin Park;Sin Dong Kang;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

Fire Monitoring System for Traditional Markets based on Digital Twin-IoT Sensing (디지털 트윈 & IoT Sensing 융합 기반 전통시장 화재 모니터링 시스템)

  • Jung-Taek Hong;Kyu-Hyup Lee;Jin-Woo Song;Seo-Joon Lee;Young-Hee Chang;Soon-Wook Kwon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_3
    • /
    • pp.1251-1258
    • /
    • 2023
  • Traditional markets are infrastructure with facilities and characteristics of very high population density. Recently, arcades have been installed through traditional market modernization policies, and aging infrastructure has been repaired. However, gas and electrical facilities of traditional markets cannot be easily replaced because of its high density. And because regular inspections are not conducted, management of facilities is on very poor condition. In addition, when a fire occurs in a traditional market, the fire easily spreads to nearby stores and is likely to spread to a large fire because of a lot of highly flammable substances. Smoke detectors and heat detectors are installed in most traditional markets to monitor fires, but malfunctions are frequent due to the nature of smoke detectors and heat detectors, and network facilities are not properly maintained. Therefore, in this study, gas detection sensors and flame detectors are additionally installed in Gwangmyeong Traditional Market, and a digital twin-based traditional market fire monitoring system is implemented in conjunction with existing sensors in the market's 3D model. With this digital twin based fire monitoring system, we can reduce the malfunctions of fire detect sensors, and can easily guide the evacuation route.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Effect the I-T curve and electrical characteristic of fuse elements by plated tin thickness (주석 도금 두께에 따른 퓨즈 가용체의 I-T 커브 및 전기적 특성의 영향)

  • Jin, Sang-Jun;Kim, Eun-Min;Youn, Jae-Seo;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.80-87
    • /
    • 2018
  • In recent years, due to the spread of various renewable energy power sources and the pursuit of high efficiency and low-power consumption, not only trends in the electric power industry but also the consumption, control methods, and characteristics are diversified. However, in this diversified electric power industry, the fuse (which is the core part responsible for safety) has not developed significantly in classical operation mode, and thus, fires continue to occur. In this paper, the effects of low melting-point metal plating and high melting-point metal plating on operating characteristics and IT curve movement of the fuse are investigated in a cartridge fuse, which is a classic fuse manufacturing method. The effects of plating on the thickness of the fuse are investigated, and various operating characteristics of the fuse are implemented. In addition, it is suggested that the plating of the low melting-point metal moves the rated current line of the fuse to a low rating, and moves operating characteristics to characteristics of delay operation. It is possible to design various operating characteristics using this characteristic.