• 제목/요약/키워드: Electrical fire prevention

검색결과 140건 처리시간 0.038초

불확실성을 고려한 다중요소 의사 결정기반의 지중전력구 감시 및 진단 (Power Tunnel Monitoring and Diagnosis Based On Multiple Attribute Making Decision with Uncertainty)

  • 이지혜;김상태;이지훈;김종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.349-350
    • /
    • 2015
  • Traditional power tunnel monitoring and diagnosis system provides simple alert in accordance with limits which set by operator using various field installed various sensor measurements. System's algorithm is too simple and it has uncertainty of sensor with error. In this paper, proposed algorithm give operator verification using installed sensor measurements such as environmental sensors for fire prevention because of cable overheat in the power tunnel.

  • PDF

식물성절연유를 사용한 친환경 주상변압기 설계를 위한 절연파괴 특성 (Breakdown Properties for Insulation Design of the Environment-Friendly Pole Transformer using the Vegetable Insulating Oil)

  • 곽동순
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.7-12
    • /
    • 2011
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The newly invented vegetable insulating oil is highly biodegradable and have negligible impact on the environment, human health and the ecosystem. For development of the environmental-friendly pole transformer using vegetable insulating oil, the dielectric constructions of the pole transformer were discussed in this paper. Depending on the dielectric constructions, the AC breakdown characteristics of the Nomex insulating papers and the vegetable insulating oil were studied by simulated electrode systems. Based on the experimental results, the maximum design stress($E_{max}$) for insulation design of the environmental-friendly pole transformer were suggested.

아크 검출기 관련 규정 마련에 관한 연구 (A study on working out arc detector related regulations)

  • 박용서
    • 디지털융복합연구
    • /
    • 제16권11호
    • /
    • pp.115-122
    • /
    • 2018
  • 국내에서 전기 화재의 70% 이상이 아크로 인하여 발생하고 있다. 본 논문에서는 이를 예방하기 위한 방안을 마련하기 위하여 기존의 누전 차단기에 관한 기술기준 및 규정을 분석하였으며, 아크 검출기에 관한 기술기준 및 규정은 아크의 특성을 고려하여 기존의 누전 차단기에 관한 기술기준 및 규정과는 별도로 제정되어야 한다는 결론을 얻었다. 따라서 본 논문에서는 아크 검출기 관련 규정은 기존 누전 차단기의 관련 규정에 추가 되거나 이것과 별개인 규정으로 제정되어야 한다고 제안하였다. 특히 아크로 인한 화재를 예방하기 위해서는 아크 검출기의 신속한 보급이 필요하고 그 설치를 의무화하는 것이 바람직하다. 따라서 이 같은 여건을 고려했을 때 기존 누전차단기 규정에 아크 검출기 관련 사항들을 추가할 것을 제안하였다. 아크 검출기의 기술 기준에는 아크의 판단 규격과 차단 임계치, 그리고 차단기가 반응하지 말아야 할 불요신호의 범위 등이 반드시 반영되어야 한다.

2.2 kW와 3.7 kW 유도전동기의 정상과 구속운전에 따른 전류 및 온도 특성 (Characteristic of Current and Temperature according to Normal and Abnormal Operations at Induction Motor of 2.2 kW and 3.7 kW)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.35-42
    • /
    • 2023
  • This study analyzed the current and temperature characteristics of major components of an induction motor during normal and abnormal operations as functions of the difference in the rated capacities of medium and large-sized motors widely used in industrial settings. The temperature rise equation of the induction motor winding was derived through locked-rotor operation experiments and linear regression analysis. When the ambient temperature is 40 ℃, the time to reach 155 ℃, the temperature limit of the insulation class (F class) of the winding of the induction motor, was confirmed to be 48 seconds for the 2.2 kW induction motor and 39 seconds for the 3.7 kW induction motor. This means that when the rated capacity is large or the installation environment is high temperature, the time to reach the temperature limit of the insulation class during locked-rotor operation is short, and the risk of insulation deterioration and fire is high. In addition, even if the EOCR (Electronic Over Current Relay) is installed, if the setting time is excessively set, the EOCR does not operate even if the normal and locked-rotor operation of the induction motor is repeated, and the temperature limit of the insulation grade of the winding of the induction motor is exceeded. The results of this study can be used for preventive measures such as the promotion of electrical and mechanical measures for the failure of induction motors and fire prevention in industrial sites, or the installation of fire alarm systems.

KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구 (A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards)

  • 이병설;최충석
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.63-72
    • /
    • 2017
  • 본 논문에서는 저압용 10회로 분전반을 전기공업협동조합(KEMC) 2102-610 규정에 근거하여 제작하였다. 또한, 개발된 10회로 분전반의 특성 평가를 실시하여 안전성을 확보하고자 한다. 개발된 10회로 분전반은 내식성, 절연 재료의 특성, 자외선 복사의 내성, 기계적 충격 등에 적합하도록 설계되었다. 개발된 분전반은 외함의 보호 등급, 감전방지와 보호회로, 개폐 장치와 구성품, 내부 전기 회로와 연결부, 외부 도체의 단자, 절연 특성, 온도 상승 시험, 열저항 등이 적합하도록 제작하였다. 개발된 10회로 분전반은 단상 회로와 3상 회로 등으로 구분되어 있다. 분기된 각각의 차단기 부하측에 센서 모듈을 설치하여 부하의 전선로에서 발생되는 누설전류의 크기를 실시간 측정할 수 있다. 그리고 부하의 용도 및 목적 등에 따라 회로를 증설할 수 있고, 각각의 부하 상태 역시 실시간 부하 관리 및 점검이 가능하다. 개발된 10회로 분전반의 온도 상승 시험을 실시한 곳은 인입 접속부, 주회로 및 분기회로 모선, 모선지지물 등 18 개소이다. 온도가 가장 높게 측정된 곳은 분기회로 모선용 MCCB 전원측 접속부의 R-phase으로 $65.3^{\circ}C$, 부하측은 T-phase으로 $61.6^{\circ}C$로 기록되었다. 그리고 내열 실험 장치를 이용하여 MCCB를 $180^{\circ}C$에서 6시간 동안 열적 스트레스를 인가하였을 때 작동 손잡이의 변형이 확인되었고, 트립 상태로 이동한 것이 확인되었다.

Characteristics of Disk-type Linear Ultrasonic Motor for Application to x-y Stage

  • Lim Kee-Joe;Park Seong-Bee;Yun Yong-Jin;Lee Kee-Young;Kang Seong-Hwa;Lee Jong-Sub;Jeong Su-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.101-105
    • /
    • 2006
  • In this paper, a disk-type ultrasonic motor using a combination of radial and bending vibration modes is newly designed and fabricated. The characteristics of the test motor are also measured. By means of traveling elastic wave induced at the surface of circumference of the elastic disk, a steel bar in contact with the surface of circumference of the elastic disk bonded onto the piezoelectric ceramic disks is driven in both directions by changing the sine and cosine voltage inputs. The stator of the motor is composed of two sheets of piezoelectric ceramic disks to bond onto both surfaces of an elastic disk, respectively. As a result, the diameter of the elastic body is increased and the resonant frequency is decreased. The resonant frequency of the stator is about 92 kHz, which is composed with piezoelectric ceramic disks of 28 mm in diameter and 2 mm in thickness, and an elastic body of 32 mm in diameter and 2 mm in thickness. A driving voltage of 20 VPP Produces 200 rpm with a torque of 1Nm and an efficiency of about 10%.

상하굴절형 내진패드를 설치한 수배전반 방재기술에 관한 연구 (A Study on the Disaster Prevention Technology of the Switchboard with Upper and Lower Bending Type Seismic Pads)

  • 이태식;석금철;이재원;김태진;김재권;조원철
    • 한국방재안전학회논문집
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2017
  • 본 연구는 빌딩과 공공시설에 설치되는 중요 전기 시설물인 수배전반이, 규모 8.3급 지진에도 국내최초로 정상적으로 작동될 수 있도록, 전기를 사용하는 각종 시설물 및 기계장치의 전원공급 및 제어하는 수배전반 하부에 상하굴절형 내진패드를 설치하여, 수배전반 하부구조 보호와 상부에 케이블 단락방지 등이 가능하도록 하여, 상하좌우 모든 지진파에 잘 적응되는 내진형 수배전반 제조기술로 한국전력이 기준으로 제시한 GR-63-CORE(규모 8.3 급) 내진성능을 만족하는, 내진형 수배전반 방재기술이다. 연구 성과로서, 전기 및 통신 기반시설을 보호할 수 있게 되어 지진발생시 전기시설을 정상상태로 복구하는 시간을 단축하는데 기여할 수 있고, 지진발생시 전기공급 시설의 파괴로 인한 화재발생을 방지할 수 있어 일본의 경우처럼 대규모 지진 발생시 발생하는 화재의 확산을 최소화하여 인명피해와 재산피해를 최소화할 수 있으며, 시민들이 대규모 지진을 겪은 후에도 일상생활로 신속히 복구할 수 있는 전기기반시설을 확보 등에 기여할 수 있다. 또한, 통신 및 전산실의 장비의 내진을 확보하기 위하여, 본 기술이 적용될 수 있고, 나아가 지진시 기반이 흔들려 시설기능이 정지될 수 있는 분야에도 다양하게 적용될 수 있을 것이다.

변압기 폭발/화재 방지 기술 (TRANSFORMER EXPLOSION AND FIRE PREVENTION)

  • 김형승;필리프매그너
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.93-94
    • /
    • 2007
  • An essential step for SERGI is to show the TRANSFORMER PROTECTOR (TP) efficacy for all transformers and all types of rupture of insulation. Its research program philosophy is thus to maintain a strong connection between experiments and the theoretical developments. Up to now, two TP test campaigns have been performed, both under the worst conditions by creating low impedance faults leading to electrical arcs inside the transformer tank dielectric oil. In 2002, Electricite de France performed 28 TP tests. Then, in 2004, a second campaign of 34 TP tests was carried out by CEPEL, the Brazilian independent High Voltage Laboratory. For the 62 tests, each transformer was equipped with the TP, which reacts directly to the moving dynamic pressure peak, shock wave, caused by the low impedance fault. When an electrical arc occurs, only one pressure peak is generated. The initial energy transfer is almost instantaneous, and so is the phase change. Because of the oil inertia, the gas is very quickly pressurised. As it is more difficult to vaporise a liquid than to crack oil-vapour into smaller molecules, the arc location would mainly remain in the gaseous phase after and less gas will be produced. As a result, when comparing tests for which pressure peaks are respectively equal to 8 bar (116 psi) and 8.8 bar (127 psi), the corresponding arc energies vary by an order 10 of magnitude (0.1 MJ and 1 MJ respectively). The correlation of the results obtained between arc energy and dynamic pressure demonstrates that the arc energy is not the key parameter during transformer tank explosion, which is in opposition with the common electrical engineers belief.

  • PDF

전기화재 예측 및 예방을 위한 IoT 플랫폼 시스템 (IoT Platform System for Electric Fire Prediction and Prevention)

  • 양승의;이성옥;정회경
    • 한국정보통신학회논문지
    • /
    • 제26권2호
    • /
    • pp.223-229
    • /
    • 2022
  • 매년 날씨가 추워지는 동절기에는 전기 사용량이 급증하는 특징을 보인다. 많은 전기를 사용하면서 인구 밀도가 높은 시장, 목욕탕, 아파트 등의 건물들의 전기 시설의 누전으로 인해 화재 발생이 늘어나고 있다. 이러한 누전화재의 원인은 대부분 전선의 노후화로 인해 사용량이 증가되어 과도하게 걸리는 부하를 견디지 못하고 전선피복이 녹아내려 주변의 발화물질로 인하여 발생하게 된다. 본 논문에서는 과부하센서, VoC센서, 과열센서로 구성된 복합 센서를 통해 전선에 발생하는 부하 및 과열을 측정하며, 이 때 발생된 유독가스를 검출하고 게이트웨이를 활용하여 서버에 로깅하는 시스템을 구현한다. 이를 바탕으로 빅데이터 분석을 진행하여 실시간으로 전기화재를 예측, 경보 및 차단이 가능한 플랫폼과 모의 화재발생 실험이 가능한 시뮬레이터를 개발한다.

전기화재 예측 및 예방을 위한 IoT 센서-게이트웨이-서버 플랫폼 개발 (Development of IoT Sensor-Gateway-Server Platform for Electric Fire Prediction and Prevention)

  • 양승의;김한길;송현옥;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.255-257
    • /
    • 2021
  • 매년 전기 사용량이 급증하는 동절기에 전통시장, 찜질방 등 다중이용시설과 아파트, 다가구주택 등 집합건물에서 노후화된 전기시설의 누전으로 인한 화재가 빈번해 지고 있다. 이러한 화재의 원인은 대부분 노후화된 전선에 과도하게 걸리는 부하로 전선 피복이 녹아내리며 주변의 발화물질에 옮겨붙어 발생하고 있다. 본 연구에서는 복합센서를 통해 전선에 걸리는 과부하와 과열을 측정하고 여기서 발생하는 유독가스를 검출하여 게이트웨이를 통해 서버에 로깅하는 시스템을 구현한다. 이를 바탕으로 빅데이터 분석을 통해 실시간 전기화재를 예측하고 경보하고 차단할 수 있는 플랫폼과 모의 화재 발생 실험이 가능한 시뮬레이터를 개발한다.

  • PDF