• Title/Summary/Keyword: Electrical fault

Search Result 3,416, Processing Time 0.034 seconds

An Efficient Test Pattern Generator for Low Power BIST (내장된 자체 테스트를 위한 저전력 테스트 패턴 생성기 구조)

  • Kim, Ki-Cheol;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.29-35
    • /
    • 2010
  • In this paper we propose a new pattern generator for a BIST architecture that can reduce the power consumption during test application. The principle of the proposed method is to reconstruct an LFSR circuit to reduce WSAs of the heavy nodes by suppressing the heavy inputs. We propose algorithms for finding heavy nodes and heavy inputs. Using the Modified LFSR which consists of some AND/OR gates trees and an original LFSR, BIST applies modified test patterns to the circuit under test. The proposed BIST architecture with small hardware overhead effectively reduces the average power consumption during test application while achieving high fault coverage. Experimental results on the ISCAS benchmark circuits show that average power reduction can be achieved up to 30.5%.

Analysis on Quench Recovery Dependence of A Flux-Lock Type SFCL According to the Winding Directions (결선방향에 따른 자속구속형 전류제한기의 퀜치 회복 의존도 해석)

  • Jung, Su-Bok;Cho, Yong-Sun;Choi, Myoung-Ho;Choi, Hyo-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.113-117
    • /
    • 2008
  • We investigated the current limiting and the recovery characteristics of a flux-lock type superconducting fault current limiter(SFCL) according to the winding directions. The flux-lock type SFCL consists of two coils. The primary coil was wound in parallel to the secondary coil through an Iron core, and the secondary coil was connected with the superconducting element in series. We have changed the winding direction of coils to compare the resistive type SFCL with the flux-lock type SFCL. The current limiting and the recovery characteristics were dependent on the winding direction. The quenching time in the additive polarity winding was faster than that of the subtractive polarity winding or the resistivity type. A consumed energy in a superconducting element was represented as $W= VIt=I^2Rt$. We found that there was a difference in the consumed energies in accordance with winding types because of differences in voltages imposed on a superconducting element in accordance with a winding direction.

The Novel Configuration of Integrated Network for Building Energy System (빌딩 에너지시스템 통합네트워크 구축에 관한 연구)

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.229-234
    • /
    • 2008
  • The new millennium has started with several innovations driven by fast evolution of the technologies in energy sector. A strong impulse towards the diffusion of new economical efficient technologies regulatory incentives related to energy production from renewable source and a small scale building trigeneration and to promotion of more sustainable environmental-friendly generation solutions, the evolution of electricity markets, more and more binding local emission constraints, and the need for improving the security of supply to reduce the energy system vulnerability. The 24 percentage energy quantify of total energy consumption consumes in commercial buildings and residential houses and the 30% portion of total $CO_2$ emissions covers also in the commercial buildings and residential houses sector. To cope with efficiently this energy sinuation in building sector, Building microgrid or building tooling, heating & power(BCHP) system has been interested in recent day due to meeting thermal and electric energy requirements efficiently and with appropriate energy quality. A multi agent system is a collective of intelligent agents that communicate with each other and work cooperatively to achieve common goals. Also, it is to medicate and coordinate communication between Control Areas and Security Coordinators for teal-time control of the BCHP system and the power pid. In this new circumstance, it is very important to integrate the power and energy delivery system and the information system(communication, networks, and intelligent equipment) that controls it. Therefore, development of smart control modules with open communication protocol and seamlessly interchange the data and information between control network and data network including extranet and intranet give a great meanings. We designed and developed the TCP/IP-CAN IED agent modules and ModBus./LonTalk/(TCP/IP) IED agent ones to configure the multi-agent system based smart energy network of commercial buildings and also intelligent algorithms for inverter fault diagnostics which ran be operated in control level or agent level network.

  • PDF

A Study on the Protection Switching Mechanism for Distribution Automation System Ethernet Networks Service of Distribution Automation System (배전자동화시스템 통신서비스를 위한 이중화 통신망 보호절체 알고리즘 연구)

  • Yu, Nam-Cheol;Kim, Jae-Dong;Oh, Chae-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.744-749
    • /
    • 2013
  • The protection switching technology is widely adopted in the fiber-optical transmission equipments based on TDM(Time Division Multiplexing), such as PDH, SDH/SONET. A variety of protection switching algorithms for Ethernet networks and the progress of standardization are summarized in the document. There are several kinds of protection switching algorithms for Ethernet networks, such as STP, RSTP, MSTP and etc. However, since Ethernet signal move through detour route, it causes much time to recover. Accordingly, it is difficult to secure a usability of Ethernet networks and QOS(Quality of Service). Also, if the protection switching protocol standardized by IEEE and ITU-T is used, it remains a inherent network switching time for protection. Therefore, a specific protection switching algorithm for Ethernet are needed for seamless and stable operation of Ethernet networks service for Distribution Automation System(DAS). A reliable protection algorithm with no switching delay time is very important to implement Self-healing service for DAS. This study of FPGA based protection switching algorithm for Ethernet networks shows that in case of faults occurrence on distribution power network, immediate fault isolation and restoration are conducted through interaction with distribution equipments using P2P(Peer to Peer) communication for protection coordination. It is concluded that FPGA based protection switching algorithm for Ethernet networks available 0ms switching time is crucial technology to secure reliability of DAS.

A Study on IoT Monitering Technology of Power Converter for E-Mobility (E-Mobility용 전력변환기의 IoT 모니터링 기술에 대한 연구)

  • Lee, In-Seok;Lee, Ju;Kang, Ja-Yoon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.39-44
    • /
    • 2018
  • In this paper, we propose a monitoring method of smartphone to integrate IoT technology to monitor the state of the vehicle for fault diagnosis of E-Mobility power converter. In China, EV regulations are being implemented to promote technological development and market changes in electric vehicles. To meet this trend, E-Mobility should study suitable monitoring technology. The OBD-II method used in existing automobiles is a wired / wireless communication method. In order to apply it to E-Mobility, additional interface and communication link are required. In this paper, we propose a technology to monitor the status information of power converter for E-Mobility by combining existing technology with IoT. This technology simplifies the existing network protocol and hardware interface, and confirms that the E-Mobility power converter and smartphone can be interworked for easy user monitoring. And we have done research to make high value product design from the aspect of function.

Development of the High Reliable Safety PLC for the Nuclear Power Plants (고신뢰도 안전등급 제어기기 개발)

  • Son, Kwang-Seop;Kim, Dong-Hoon;Son, Choul-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.109-119
    • /
    • 2013
  • This paper presents the design of the Safety Programmable Logic Controller (SPLC) used in the Nuclear Power Plants, an analysis of a reliability for the SPLC using a markov model. The architecture of the SPLC is designed to have the multiple modular redundancy composed of the Dual Modular Redundancy(DMR) and the Triple Modular Redundancy(TMR). The operating system of the SPLC is designed to have the non-preemptive state based scheduler and the supervisory task managing the sequential scheduling, timing of tasks, diagnostic and security. The data communication of the SPLC is designed to have the deterministic state based protocol, and is designed to satisfy the effective transmission capacity of 20Mbps. Using Markov model, the reliability of SPLC is analyzed, and assessed. To have the reasonable reliability such as the mean time to failure (MTTF) more than 10,000 hours, the failure rate of each SPLC module should be less than $2{\times}10^{-5}$/hour. When the fault coverage factor (FCF) is increased by 0.1, the MTTF is improved by about 4 months, thus to enhance the MTTF effectively, it is needed that the diagnostic ability of each SPLC module should be strengthened. Also as the result of comparison the SPLC and the existing safety grade PLCs, the reliability and MTTF of SPLC is up to 1.6-times and up to 22,000 hours better than the existing PLCs.

A Study on the Restoration System for Distribution Networks Using Dynamic Division Method (동적분할 기법을 이용한 배전망의 정전복구 시스템에 관한 연구)

  • 임찬호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.64-72
    • /
    • 2003
  • Comparing with transmission networks, the faults in distribution networks more often occurs because of the complicated structure and the adjacency to customers. Moreover the faults give direct damage to customers. So fault diagnosis and blackout restoration in distribution networks are very important elements to reduce the damage of customers and to maintain the stability. The restoration problem of distribution networks is subject to time. Minimizing the switching numbers in restoration process is the crucial element. In other words. the best restoration is to restore all blackout area through just one switching, if not the restoration has to be accomplished through several switching. This paper proposes the efficient restoration system in distribution networks to minimize the switching numbers. The proposed system uses the dynamic division method of hierarchical structure which consists of heuristic searching method and meta algorithm. The proposed system is applied to the sample networks, and the results showed a promising possibility.

Malfunction Measures and Susceptibility test of Elevator Based on EMS(Electromagnetic Susceptibility) Standard (EMS 규정에 따른 승강기 내성시험 및 오동작 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Lee, Joo-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.78-85
    • /
    • 2007
  • The malfunction accidents such as kept within elevator, sudden rise, sudden stop, error of level indication which can bring about uneasiness of elevator passenger and be related with life accident are occurring. However, as there is not field recurrence for this portion and they are accidents that occur and then disappear, it is actually difficult to confirm the reason of accident. Therefore, we made an experiment for tolerance in three models which is being built recently according to EN12016(2004) standard and analyzed the movement characteristics of elevator to study the reason which can bring about confine and malfunction. Furthermore after supplementing measures for malfunction, Finally this paper will be used as reference to suggest methods for malfunction of elevator facility and the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

Development of Process Control Graphic System for Power Plant Using Multiple Microcomputers (다중 마이크로 컴퓨터를 이용한 발전소 공정제어 그래픽 시스템의 개발)

  • ;;;Zeungnam Bien
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.3
    • /
    • pp.217-227
    • /
    • 1989
  • A process control graphic system is proposed as an efficient tool for monitoring the operation of power plant. It uses the multi-processor structure with 60 Kbyte shared memory as an implemental type of the distributed computer system, so that it is flexible, functionally extensible, and applicable to real-time process. The shared memory is used as a real-time database handling the process values and operator's commands. The database files, generated by the user-interactive graphic editor developed for the system or text editor, have the characteristics of simplicity and user-friendliness. The process control graphic system, that can monitor the operation of boiler and function as a backup controller in case of failure in boiler controller, is applied to Ulsan power plant. As a result, it displays the operating data of the boiler process without error by 14 pages of color graphic image according to the operation menu, and additionally functions well as a fault-tolerant control system.

New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents (누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치)

  • 길경석;한주섭;송재영;조한구;한문섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.