• Title/Summary/Keyword: Electrical discharges

Search Result 418, Processing Time 0.028 seconds

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).

A New Type of Nonthermal Plasma Reactor

  • Geum, Sang-Taek;Moon, Jae-Duk;Jun, Sun-Gon
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.245-249
    • /
    • 1999
  • A new type of nonthermal plasma reactor utilizing ferroelectric pellets is proposed to generate nonthermal plasma efficiently, which is used for simultaneous control of various pollutant gases. Electric charges stored on ferroelctric pellets by corona discharge between a corona tip and a mesh electrode provide partial electrical discharges among ferroelectric pellets. These partial electrical discharges can enhance partial discharges around the surface of ferroelectric pellets. This method utilizes wide reacting area of ferroelectric pellets and partial discharge. Positive and negative dc voltage are applied to the corona tip to generate partial discharges, and corona currents are estimated to investigate charge storage on ferroelectric pellets as function of time and charge relaxation time constants of ferroelectric pellects. As a result, charge relaxationtime, dielectric constants of ferroelectric pellets, polarity of applied voltage and applied time influence partial discharges among ferroelectric pellect.

  • PDF

A Fundamental Study on the Impulse Responses of Ground Rod Attendant upon Soil Discharges (토중방전을 수반하는 접지봉의 임펄스응답에 대한 기초적 연구)

  • Yoo, Yang-Woo;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.62-69
    • /
    • 2014
  • This paper deals with the fundamental characteristics of transient and conventional ground impedances associated with soil discharges when the lightning impulse voltage was applied to a small-sized ground rod. The potential rise responses of the test ground rod to impulse currents were observed. The current-voltage (I-V)curves, transient and conventional ground impedance curves were examined.. To analyze the transient behaviors of ground rod attendant upon soil discharges, the impulse responses of ground rod were compared with those of non-inductive resistor. As a consequence, the potential rise and impedance of ground rod were reduced and the currents dispersed into the earth were increased due to soil discharges near the ground rod. Soil discharges are classified into two regimes; ionization and breakdown phenomena. The potential rise and impulse impedance of ground rod are significantly decreased by breakdown processes in soil.

Frequency Spectrum Analysis of Series Arc and Corona Discharges (직렬 아크 및 코로나 방전의 주파수 스펙트럼 분석)

  • Kil, Gyung-Suk;Jung, Kwang-Seok;Park, Dae-Won;Kim, Sun-Jae;Han, Ju-Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.554-559
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic pulses generated by series arc- and corona- discharges as a basic study to develop an on-line diagnostic technique for power facilities installed inside closed-switchboards. To simulate series arc and corona discharges, five types of electrode system which consists of needle and plane electrodes were arranged. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an ultra log antenna and an EMI receiver. From the experimental results, the frequency spectrum exists in ranges from 30 MHz to 2 GHz for a series arc discharge and 30 MHz to 1.2 GHz depending on defects for a corona discharge. The peak frequency of the series arc- and corona- discharges were 100 MHz to 160 MHz and 40 MHz to 80 MHz, respectively.

Parameter Characteristics of the Electric and Magnetic Field Waveforms Associated with Lightning Discharges (뇌방전에 의해서 발생하는 전계와 자계파형의 파라미터 해석)

  • Park, Sung-Yeol;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1867-1869
    • /
    • 1996
  • In this paper, in order to obtain the statistic information for parameters of electric and magnetic field waveforms associated with lightning discharges, the electric and magnetic fields produced by lightning discharges in the summer of 1995 were measured by a hemisphere-type electric field sensor and a loop-type magnetic field sensor, which were installed at the campus of Inha University in Inchon. The signals of the electric and magnetic fields were continuously recorded by a transient digitizer having a resolution of 12 bit and a memory capacity of 5000 point. Negative lightning discharges are produced very more than positive lightning discharges in the summer of Korea. The 10 to 90 % rise time of electric and magnetic fields was 2 $2\;{\sim}\;10\;{\mu}s$. And the zero-crossing time of electric field was $15\;{\sim}\;25\;{\mu}s$, whereas that of magnetic field was $20\;{\sim}\;30\;{\mu}s$.

  • PDF

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

Characteristics of Electric Field Change Associated with Multiple-Lightning Discharges (다중 뇌방전에 의하여 발생하는 전계 변화의 특성)

  • Lee, Bok-H.;Ahn, Chang-H.;Lee, Seung-C.;Sim, Pan-S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1650-1652
    • /
    • 1998
  • This paper describes characteristics of electric field waveforms associated with multiple-lightning discharges. The electric field measurment system. consists of hemi-sphere antenna 30 cm in diameter. integrator and data acquisition device. The frequency bandwidth is from 200 Hz to 1.56 MHz, and the sensitivity is 0.96 mV/V/m. The detected electric field signal is digitized every 500 ns with the resolution of 12-bit and the length of 2 kilowords and is registered at a personal computer. Also parameters of the electric fields associated with multiple-lightning discharges are ststistically analyzed.

  • PDF

comparison of Partial Discharge Characteristics of DC Voltage (DC 부분방전 특성 비교)

  • Kim, Woo-Bin;Yoon, Ji-Sub;Yoon, Sung-Ho;Nam, Gi-Jin;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1159-1159
    • /
    • 2015
  • This paper conducted the basic study on partial discharge analysis under the DC voltage. For the purpose, typical discharges such as void discharges, corona discharges and surface discharges with DC voltage were generated and measured. As a pattern analysis, various methods were adopted using the information including PD magnitudes and time interval.

  • PDF

Effects of Soil Discharges on the Impulsive Ground Impedance of Ground Rod with Needles (침상 접지봉의 임펄스접지임피던스에 미치는 지중방전의 영향)

  • Yoo, Yang-Woo;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.98-105
    • /
    • 2014
  • Soil discharges near the ground rod play an important role to reduce the ground potential rise and the ground impedance and to help the fault current to spread into the earth. This paper presents the effects of soil discharges on the transient and conventional ground impedances when the lightning impulse voltage was applied to a ground rod with radial needles. The current-voltage (I-V)curves and transient ground impedance curves were calculated based on the measured current and potential traces. Soil discharge behaviors related to I-V curves and transient ground impedance curves were analyzed as a function of the magnitude of lightning impulse voltages. As a result, the soil discharges occurred near the ground electrode contribute to the reduction of conventional ground impedance and limits the ground potential rise effectively under lightning impulse voltages.

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.