• 제목/요약/키워드: Electrical discharge

검색결과 3,705건 처리시간 0.034초

공구전극곡면에 의한 3차원 방전가공조건의 결정 (Determination of Parameters for 3-Dimensional Electrical Discharge Machining by a Tool Electrode Surface)

  • 주상윤;이건범
    • 한국정밀공학회지
    • /
    • 제17권1호
    • /
    • pp.27-33
    • /
    • 2000
  • This paper presents a method for determining machining parameters in 3-dimentional electrical discharge machining(EDM). The parameters are the peak value of currents, the pulse-on time, and the pulse-off time. It is known that they influence the performance of EDM more than the other else. The parameters are determined from the discharge area between a tool electrode and a work piece. The discharge area is directly influenced by the geometry of a tool surface and the tool discharge position. The discharge area on a tool discharge position is calculated from intersection curves between the tool surface and a horizontal plane. The grid search method is applied to determine the intersection curves. An example is introduced to show that the machining parameters are obtained from the surface geometry of a tool electrode.

  • PDF

최적화된 pRBF 뉴럴 네트워크에 이용한 삼상 부분방전 패턴분류에 관한 연구 (A Study on Three Phase Partial Discharge Pattern Classification with the Aid of Optimized Polynomial Radial Basis Function Neural Networks)

  • 오성권;김현기;김정태
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.544-553
    • /
    • 2013
  • In this paper, we propose the pattern classifier of Radial Basis Function Neural Networks(RBFNNs) for diagnosis of 3-phase partial discharge. Conventional methods map the partial discharge/noise data on 3-PARD map, and decide whether the partial discharge occurs or not from 3-phase or neutral point. However, it is decided based on his own subjective knowledge of skilled experter. In order to solve these problems, the mapping of data as well as the classification of phases are considered by using the general 3-PARD map and PA method, and the identification of phases occurring partial discharge/noise discharge is done. In the sequel, the type of partial discharge occurring on arbitrary random phase is classified and identified by fuzzy clustering-based polynomial Radial Basis Function Neural Networks(RBFNN) classifier. And by identifying the learning rate, momentum coefficient, and fuzzification coefficient of FCM fuzzy clustering with the aid of PSO algorithm, the RBFNN classifier is optimized. The virtual simulated data and the experimental data acquired from practical field are used for performance estimation of 3-phase partial discharge pattern classifier.

다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성 (Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths)

  • 김영선;김동민;이기식
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

UV-IR 카메라를 이용한 전력설비 진단을 위한 전기 및 광학적 안전 기준 설정 연구 (A Study of Electrical and Optical Method of Safety Standards for diagnosis of Power Facility using UV-IR Camera)

  • 김영석;김종민;최명일;방선배;송길목;곽동순
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.54-61
    • /
    • 2013
  • UV-IR camera is being used for predictive maintenance of high voltage equipment together with measurement of temperature on localized heat and corona discharge. This paper was suggested the judgement method that is the discharge count, UV image pattern and discharge matching rate to apply the UV-IR camera on power facility. The discharge count method is counted by UV image pixel value. the UV image pattern method is determined by the UV image shape using neural network algorithm method, separated by Sunflower, Jellyfish, Ameba. The UV discharge matching is compare the breakdown the UV image size and measuring UV image size according to distance.

전력설비의 열화 진단을 위한 연면방전 모델에서의 코로나 방전 특성 분석 (The Analysis of Corona Discharge of Surface Flashover Model for Aging Diagnosis of Power Facility)

  • 방만식;최재형;김우진;김영석;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.314-318
    • /
    • 2011
  • Recently, ultrasound, infrared detector, V-I characteristic, gas analysis, UV (ultra-violet rays) camera etc. is used as inspections and diagnoses of the safety of power equipment. Especially, UV camera have attracted a great deal of interest from the view point of easy judgement. UV camera is used corona discharge. One of the most important and difficult problems to be solved filer design, materials and corona discharge. This paper is studied on the temperature characteristics, UV generation and shape analysis and corona pulse count according to the electrode distance and applied voltage. Also, Corona discharge characteristics in air are analyzed using prototype UV camera of Korea. UV generation due to surface discharge of AC is higher than that of DC.

분포통계변화에 따른 XLPE 절연체의 부분방전 패턴해석 (Analysis of The Partial Discharge Pattern in XLPE Insulator due to Variation of Statistical Distribution)

  • 김탁용;;조경순;심현택;연규호;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.83-84
    • /
    • 2006
  • In this paper, we examine discharge characteristics of cross-linked polyethylene (since then; XLPE) according to thickness. Voltage was applied to power frequency by step method, and calibration of discharge was set to 50[pC] (slope=8.333). After the voltage was applied, for 10 [sec] (600 [cycle]), occurring discharge and number were detected. Determine of input pattern is difficult because discharge pattern is irregular. Therefore we investigated pattern using the K-means Analysis and Weibull function. Also we investigated variation of centroid and cluster.

  • PDF

글로우 방전 플라즈마 진단 특성 (The Characteristics of Glow Discharge Plasma Diagnosis)

  • 우성훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.372-375
    • /
    • 2009
  • We have studied on plasma diagnosis, characteristics of the glow discharge at the several different conditions of pressure, discharge current and such. The discharge onset voltage and onset current decreased as pressure increase, the general trend was nearly in agreement with the left regions of Paschen's curve. As normal glow discharge, discharge voltage was constant according to discharge current.

  • PDF

고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석 (Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics)

  • 강성화;홍현문;류부형
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

GIS내 파티클의 상태에 따른 전기적 방전 신호 분석 (Analysis of Electrical discharge signal according to particle state in GIS)

  • 이동준;이곤;곽희로;김경화;권동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1084-1086
    • /
    • 1999
  • The breakdown was caused by particle in GIS and various methode was suggested to find particle in GIS. In this paper, four states of particle was imitated which are particle on electrode, particle on enclosure, particle on spacer and crossing particle. The discharge voltage of each states was classified by four voltages which are initial, development, later and close discharge voltage. $\Phi$-Q-N pattern was analyzed according to the states and to the discharge voltages. In the result, the electrical discharge pattern according to the particle states may be distinguished.

  • PDF

Some Micro-discharge Characteristics of the cells in ac-PDP

  • Son, Jin-Boo;Lee, Sung-Hyun;Lee, Dong-Hyun;Kim, Young-Dae;Cho, Jung-Soo;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.103-104
    • /
    • 2000
  • Voltage transfer curves have been used for analyzing the micro-discharge characteristics of cells in ac-PDP. This paper deals with the effect of working gas species, pressure and frequency of applied voltage on the micro-discharge characteristics. Using the mixture gases of He+Xe or He+Ne+Xe, wall voltage steeply varied compared with only He gas, and also voltage margin increased. Discharge voltage and voltage margin increased with increasing Xe percentage, and also wall voltage more steeply varied. In addition, the variation of effective wall capacitance which is significantly dependent on the discharge strength is discussed.

  • PDF