• Title/Summary/Keyword: Electrical curtain

Search Result 28, Processing Time 0.021 seconds

The Design and Implementation of Electromotion Curtain System using PLC and CDM Controller

  • Choo, Yeon-Gyu;Kang, Sung-Soo;Kim, Bong-Gi
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.443-448
    • /
    • 2010
  • The electrical curtain is an electronic product which is most suitable for the sphere of intelligent home network. It provides the basic feature of intelligent home network such as the followings; various functions, powerful control. It also becomes the ideal technology with inexpensive power-line protocol, energy saving and solar power generation. Generally it is a suitable motor for BLDC to move the electrical curtain, because it provides the maintenance without difficulty, long-lived use with good efficiency. On this paper, we proposed the BLDC motor controller designed by CDM(Coefficient Diagram Method) and evaluated its performance with a simulation of the plant, designed the electrical curtain using BLDC motor and powe-line protocol.

The Design and Implementation of Electromotion Curtain System using BLDC Motor (BLDC 모터를 이용한 전동커튼시스템 설계 및 구현)

  • Choo, Yeon-Gyu;Kim, Bong-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.763-766
    • /
    • 2009
  • The electrical curtain is an electronic product which is most suitable for the sphere of intelligent home network. It provides the basic feature of intelligent home network such as the followings; various functions, powerful control. It also becomes the ideal technology with inexpensive power-line protocol, energy saving and solar power generation. Generally it is a suitable motor for BLDC to move the electrical curtain, because it provides the maintenance without difficulty, long-lived use with good efficiency. On this paper, we proposed the BLDC motor controller desinged by CDM(Coefficient Diagram Method) and evaluated its performance with a simulation of the plant, designed the electrical curtain using BLDC motor and powe-line protocol.

  • PDF

A Study on the Efficiency of Water Curtain around the Underground Oil Storage Cavern (지하유류비축공동(地下油類備蓄空洞)에서 Water Curtain의 효율성(効率性)에 관한 연구(硏究))

  • Chung, Hyung Shik;Lee, Ik Hyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.87-94
    • /
    • 1983
  • The successful oil storage in the underground cavern is dependent on how to keep the water-tightness around the cavern by the groundwater. If the water-tightness is not secured, gas bubles will leak out and oil migrate to the adjacent empty cavern. An electrical analogy method was employed in studying the influences of the position of horizontal and vertical water curtains, the head of water curtain and the intervals of the cavern spacings and boreholes on the gas leakage and the oil migration into the adjacent empty cavern. The result shows that if the cavern spacing is narrow, the vertical water curtain should be established and if the cavern spacing is more than twice the cavern height, its establishment is not necessary. All the detailed factors required to prevent the oil migration are shown on graphs.

  • PDF

The Characteristics on CIGS Thin Film PV Module for Curtain Wall Spandrel Applications (커튼월 스팬드럴 적용을 위한 CIGS 박막 모듈의 특성 분석 연구)

  • Kang, Jun-Gu;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.107-113
    • /
    • 2013
  • In this study, three different types of experimental models of BIPV curtain wall units with GIGS modules were built, and their thermal and electrical performances were analyzed. The experimental results showed that the temperature of the rear side of the GIGS module with the application of an insulation in the curtain wall spandrels was higher than a GIGS module standalone by $22^{\circ}C$, which results in a reduction in the power generation of the former by 8 %. On the other hand, when ventilation was applied to the model to improve the power generation performance, the module temperature was observed to be $142^{\circ}C$ lower compared to the enclosed type, and the power generation performance improved by 5 %. It confirmed that the temperature increase in the rear side of the GIGS module with insulation layer reduced the electrical performance of the module. Based on this, it is claimed that providing sufficient ventilation at the GIGS applied spandrels contribute to improve the power generation of the GIGS module.

Design of Successive Safety Light Curtain System Using Single Chip Microprocessor (단일칩 마이크로 프로세서로 구현한 연속 차광 감지 시스템의 설계)

  • Park, Chan-Won;Lee, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3233-3235
    • /
    • 1999
  • This paper describes development of a microprocessor-based optoelectronic guard system established a higher level of control reliability in machine guard design. The system uses the design concept of diverse redundancy and a fast software algorithm. We have accomplished an safety light curtain system that allows to be intentionally disabled moving machine by the interrupt of dangerous situations. As a result, it is showed that the proposed system is effective enough to practical applications.

  • PDF

PV module manufacture for application of Building Integrated photovoltaic system (건물일체형 태양광발전시스템(BIPV) 적용을 위한 태양전지모듈 제조)

  • Kang Gi-Hwan;Yu Gwon-Jong;Han Deuk-Young;An Hyung-Geun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1465-1467
    • /
    • 2004
  • In this paper, deduced manufacturing condition of glass/glass curtain wall module and metal curtain wall module. From the results. lamination condition of glass/glass curtain wall module deduced optimum in pumping $time-120^{\circ}C$ 23min, slow $press-120^{\circ}C$. 300mmHg. 3min. standard $press-120^{\circ}C$. 200mmHg. 0.5min. fast $press-120^{\circ}C$. 100mmHg. 0.3min and $curing-140^{\circ}C$, 6min, and lamination condition of metal curtain wall module deduced optimum in pumping $time-120^{\circ}C$. 8min, slow $press-120^{\circ}C$, 700mmHg. 0.5min, standard $press-120^{\circ}C$, 600mmHg, 0.5min. fast $press-120^{\circ}C$, 100mmHg. 1.5min and $curing-140^{\circ}C$. 6min. This time. power uniformity of glass/glass curtain wall module and metal curtain wall module showed each ${\pm}2.7\%,\;{\pm}2.12\%$.

  • PDF

Implementation of Active Noise Curtains for Long Distance Noise (원거리 소음 제거를 위한 능동방음막 구현)

  • Nam, Hyun-Do;Kwon Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.154-160
    • /
    • 2004
  • In this paper, implementation of active noise curtains using multiple channel adaptive filters is presented. The same numbers of single channel LMS algorithms as control loudspeakers is used instead of a multi-channel LMS algorithm to reduce the computational burden of adaptive filter algorithms. In general, a multi-channel LMS algorithm is usually used in active noise control system. but this algorithm has much more computational complexity. The single channel control techniques have less amount of DSP calculation, compared to multiple channel control techniques. A stabilizing procedure for adaptive IIR filters is also proposed to improve the stability of recursive LMS algorithms. Both experimental results of two control techniques using TMS320VC33 digital signal processor show the similar noise reduction, but the single channel control techniques are more efficient in practical active noise curtain applications

A Study on the Thermal Characteristics of BIPV Applied on Curtain Wall Spandrel (스팬드럴 적용 BIPV의 후면 열 특성에 관한 연구)

  • Lee, Sang-Gil;Kang, Tae-Woo;Jang, Han-Bin;Kang, Gi-Hwan;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.120-126
    • /
    • 2012
  • BIPV is applied to buildings in various forms. However, there are some aspects of consideration in applying PV systems in buildings, such as attaching methods, PV electrical efficiency, appearance and so on. BIPV can be installed on curtain wall spandrel as finishing material, which may combine with insulation. The thermal characteristic of spandrel with BIPV has rarely been studied; the temperature of air space between PV module and insulation layer affects both the electrical behavior of PV module and the energy load in a building. This paper aims to analyse the temperature variation of the layers in BIPV spandrels. In this paper, the temperature of layers, including the air space and PV module, was measured for three different type of BIPV applications on spandrel. The results show that the temperature of air layer for the spandrel with G/G(2) type BIPV module on October was the highest among other months.

Comparison of Performance Analysis of the Ventilated and Non-­ventilated CIGS BIPV Units (환기 유무에 따른 CIGS BIPV 커튼월 유닛의 성능 비교 분석)

  • Kim, Sang-Myung;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.47-57
    • /
    • 2017
  • CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was $6.8^{\circ}C$ lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

Analysis of Temperature and Power Generation Characteristics of Bifacial BIPV System Applied into Curtain Wall (양면형 BIPV 시스템의 커튼월 적용에 따른 온도 및 발전특성 분석)

  • Kang, Jun-Gu;Kim, Yong-Jae;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.57-66
    • /
    • 2015
  • BIPV system not only produces electricity at building, but also acts as a material for building envelope. Thus, it can increase the economical efficiency of PV system by saving the cost for building materials. Bifacial solar cell can convert solar energy to electrical energy from both sides of the cell. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial solar cells. Therefore, many of the module manufacturers can easily use the bifacial solar cells without changing their manufacturing equipments. Moreover, bifacial PV system has much potential in building application by utilizing glass-to-glass structure of PV module. However, the electrical generation of the bifacial PV module depends on the characteristics of the building surface which faces the module, as well as outdoor environment. Therefore, in order to apply the bifacial PV module to building envelope as BIPV system, its power generation characteristics are carefully evaluated. For this purpose this study focused on the electrical performance of the bifacial BIPV system through the comparative outdoor experiments. As a result, the power generation performance of the bifacial BIPV system was improved by up to 21% compared to that of the monofacial BIPV system. Therefore, it is claimed that the bifacial BIPV system can replace the conventional BIPV system to improve the PV power generation in buildings.