• Title/Summary/Keyword: Electrical characteristics

Search Result 19,311, Processing Time 0.042 seconds

Some Micro-discharge Characteristics of the cells in ac-PDP

  • Son, Jin-Boo;Lee, Sung-Hyun;Lee, Dong-Hyun;Kim, Young-Dae;Cho, Jung-Soo;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.103-104
    • /
    • 2000
  • Voltage transfer curves have been used for analyzing the micro-discharge characteristics of cells in ac-PDP. This paper deals with the effect of working gas species, pressure and frequency of applied voltage on the micro-discharge characteristics. Using the mixture gases of He+Xe or He+Ne+Xe, wall voltage steeply varied compared with only He gas, and also voltage margin increased. Discharge voltage and voltage margin increased with increasing Xe percentage, and also wall voltage more steeply varied. In addition, the variation of effective wall capacitance which is significantly dependent on the discharge strength is discussed.

  • PDF

A study on the relationship between the condition of addressing and the characteristics of surface discharge in ac-PDP (ac-PDP에서의 어드레스 조건과 면방전 특성과의 상관관계에 관한 연구)

  • Yeo, J.Y.;Lee, K.B.;Lee, W.G.;Son, J.B.;Park, C.H.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2016-2018
    • /
    • 1999
  • Until now, there is no report for the relationship between the condition of addressing and the characteristics of surface discharge in ac- PDP. We have known that such experiments were important to drive a-PDP. Therefore, This paper deals with the probability of transfer and the characteristics of luminance according to addressing voltage (Va), blocking voltage (Vg)in addressing period and sustain voltage(Vs)in sustaining period and we use waveform according to ADS (Address and Display period Separation) method.

  • PDF

Effect of Magnetic Field on Negative DC Corona Discharge (부극성 직류 코로나 방전에 미치는 자계의 영향)

  • Park, J.Y.;Kim, I.K.;Jung, J.G.;Kim, G.H.;Kim, J.D.;Koh, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2308-2310
    • /
    • 1999
  • The effect of magnetic field on NOx removal characteristics from a combustion flue gas has been experimentally investigated for a DC corona discharge reactor with a multipoint plate geometry in our Lab. Combustion flue gas removal efficiency of this type was much higher than that of the other types. In this paper, needle-plate geometry discharge system with applied magnetic field at a right angle to the electric field was made. Input power source was used negative DC. The corona discharge characteristics for this system was investigated and compared with the corona characteristics for the corona discharge system without magnetic field.

  • PDF

Dynamic Electrical Breakdown Characteristics of Liquid Nitrogen (액체 $N_2$의 동적 절연파괴 특성)

  • 김영석;정종만;곽민환;백승명;장현만;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.359-362
    • /
    • 1998
  • Electrical breakdown characteristics of liquid nitrogen(LNd used as both coolant and insulator for high $T_c$ superconductor system is very important. This paper presents dynamic breakdown characteristics of liquid nitrogen by quench penomena of thermal bubble under high electric field. As the result, the breakdown mechanism of $LN_2$ depends on thermal bubble effect. The breakdown voltage decreases slightly with increasing heating. In the Electrode arrangement, electrical breakdown voltage of horizontal arrangement appears lower than that of vertical arrangement.

  • PDF

The Electrical Salt-Fog Performance of Si1icone Rubber Material Aged by Water Immersion (수분침투로 열화된 실리콘 고무의 젼기적 염해 특성)

  • 연복회;이상엽;황명근;김완태;허창수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.25-28
    • /
    • 1998
  • In this study, we investigated the electrical characteristics of silicone rubber that being used outdoor insulating material, which had been immersed in salt water. After immersed the sample in salt water, we measured surface hydrophobicity, weight loss and microscopic surface appearance, and then compared with these of the original. And we tested the electrical characteristics of the aged sample by the water under salt-fog. These electrical characteristics are described by the average of leakage current, peak pulse number, which are recorded by data acquisition system The experimental results show that the resistance against tracking and erosion is decreased significantly by water penetration.

  • PDF

Electrical Characteristic Assessment of Nomex Paper for Distribution Transformers

  • Song, Il-Keun;Jung, Jong-Wook;Lee, Byung-Sung;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.86-90
    • /
    • 2003
  • This paper describes the electrical characteristics of Nomex paper employed as an insulating material for distribution transformers. The relative permittivities (dielectric constants) and tan$\delta$ (dielectric dissipation factors) were measured as dielectric characteristics and the partial discharge inception voltages (PDIVs) and breakdown voltages were also measured as electrical strength characteristics of Nomex paper. As a result, the permittivity and tan $\delta$ of Nomex paper demonstrated both temperature and frequency dependency. Of particular note, the permittivity of 0.18 mm Nomex paper was 2.4 according to the ASTM condition, The PDIVs and breakdown voltages were almost linearly increased with the thickness of Nomex paper. Furthermore, its electrical strength was superior to conventional Kraft paper.

Electric Characteristics on the Insulating Paper with Varnish-Impregnant (바니쉬 함침이 절연지에 미치는 영향)

  • Kim, Pil-Hwan;Kim, Ju-Han;Lee, Won-Yeong;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.180-182
    • /
    • 2004
  • We have investigated characteristics of varnish and oil impregnant. When transformers are manufactured with some moisture and varnish impregnant not entirely dried, those should be caused by factors that deteriorate the electrical or mechanical property after installation. Therefore, in this study we experienced moisture content of the new insulating paper and the varnish impregnant paper in the ratio of time for confirming factors that deteriorate the paper characteristics. Besides, we investigated a property study that was experienced the value of dielectric strength and tensile strength as no serviced insulating samples of transformer.

  • PDF

Effects of Flip-chip interconnect elements on the transmission characteristics (플립칩 연결부 구성요소들이 전송특성에 미치는 영향)

  • Lee, Jae-Hoon;HwangBo, Hoon;Nah, Wan-Soo;Joo, Jin-Ho;Jung, Seung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2357-2359
    • /
    • 2005
  • In this paper, we analyzed the effect of flip chip interconnect which is a part of FC-BGA package on the transmission characteristics of interconnect. We designed simple interconnect model and analyzed the change of the transmission characteristics as the size of each component change. And we provided design guide of interconnect which shows more enhanced results.

  • PDF

Dynamic Characteristics Analysis of Linear DC Motor Using 3D Equivalent Magnetic Circuit Network Method by Voltage Driven (전압구동 3차원 등가자기회로망법을 이용한 선형 직류전동기의 동특성 해석)

  • Yeom, Sang-Bu;Ha, Kyung-Ho;Hong, Jung-Pyo;Hur, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.271-273
    • /
    • 2000
  • This paper presents the dynamic characteristics Linear DC Motor(LDM) using 3 Dimensional Equivalent Magnetic Circuit Network Method(3-D EMCN) by voltage driven. The movement of mover substitutes for the movement of magnetization in permanent magnet expressed by Fourier series. The Dynamic characteristics are carried out from coupling the electrical circuit equation and mechanical kinetic equation.

  • PDF

Arcing horn design specification and electrical characteristics special quality estimation of distribution line (배전선로의 내뢰흔 설계사양 및 전기적 특성 평가)

  • Kim, Seok-Sou;Choi, Ik-Sun;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.472-473
    • /
    • 2007
  • This study evaluated electrical characteristics of the manufactured arcing horn whose rated voltage and nominal discharge current were 18kV and 2.5kA, respectively. In this study, residual voltage and lightning impulse flashover voltage were examined. The arcing horn showed excellent electrical characteristics that residual voltage and lightning impulse flashover voltage were 55kV below and 121kV at 115mm, respectively. Therefore the manufactured arcing Horn is considered that it would show good performance for protecting electrical wires and line post insulators from lightning impulse, if it were applied to real fields.

  • PDF