• Title/Summary/Keyword: Electrical characteristics

Search Result 19,269, Processing Time 0.043 seconds

Characteristics of Pentacene Thin Film Transistors with Stacked Organic Dielectrics for Gate Insulator

  • Kang, Chang-Heon;Lee, Jong-Hyuk;Choi, Jong-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.184-187
    • /
    • 2002
  • In this work, the electrical characteristics of organic thin film transistors with the stacked organic gate insulators have been studied. PVP(Polyvinylphenol) and polystyrene were used as gate insulating materials. Both the high dielectric constant of PVP and better insulating capability of polystyrene were compensatorily adopted in two different stacking orders of PVP-polystyrene and polystyrene-PVP. The output characteristics of the device with the stacked gate insulator showed substantial improvement compared with those of the devices with either PVP or polystyrene gate insulator: Furthermore, these stacked organic gate insulators can differently affect the TFT characteristics with the stacking orders. The electrical properties of TFTs with organic gate insulators stacked in different orders are discussed.

  • PDF

고온 다습하에서 복합절연재료의 열화특성 (The aging characteristics of composite insulating materials due to high-temperature and high-moisture)

  • 이종호;이규철;김순태;박홍태
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권1호
    • /
    • pp.15-24
    • /
    • 1994
  • For increasing the insulating proper-ties and the reliability of composite materials due to environmental aging, the electrical and mechanical characteristics of moisture absortion specimens and moisture desorption specimens were investigated. After moisture absorption wt% and moisture desorption wt% increased with time, a state of saturation arrived subsequent to a constant time. Moisture absorption constants with the layers of glass fiber showed 0.0117 in 1 layer, 0.0123 in 2 layers and 0.0152 in 3 layers. Electrical and mechanical characteristics dropped significantly with moisture absorbing in composite materials. Although moisture dried completly at 70.deg. C, it is impossible to obtain the electrical and mechanical characteristics before moisture absorption. Many defaults by moisture in composite materials exist at interface between epoxy matrix and filler.

  • PDF

다중방전형 오존발생기의 방전 및 오존생성특성 (Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer)

  • 전병준;문경수;송현직;김긍영;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

Showering Discharge형 오존발생장치의 특성 (The Characteristics of Showering Discharge Type Ozonizer)

  • 김금영;문경수;송현직;이광식;이동인;전영주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2248-2250
    • /
    • 1999
  • In this paper, showering discharge type ozonizer has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flux and discharge power.

  • PDF

Matlab을 이용한 PV모듈의 I-V시뮬레이션 관한 연구 (Study on I-V simulation for PV module with matlab)

  • 홍종경;정태희;강기환;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.1-6
    • /
    • 2009
  • This paper estimates numerically cells the electrical characteristics of the PV module with environmental changes such as shunt resistance, series resistance, temperature, irradiance. Series resistance $R_s$ including diode characteristic resistance $r_d$ is derived from the p-n junction diode model. I-V characteristics of this model with series resistance $R_s$ are simulated on Matlab. Finally, theoretical I-V characteristics are compared with those of solar simulator. Those results agreed well within the manufacturer's maximum error range 3%

Axial flux BLDC 전동기의 토크특성개선에 관한 연구 (Analysis of characteristics of Multi-layer AFPM Motor)

  • 유현오;공정식;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.397-399
    • /
    • 1999
  • This paper deals with the torque characteristics of a AFPM motor excited by permanent magnets. According to relative angle difference of two rotor, torque characteristics are studied. According to varied angle of two rotor, torque ripple and, total torque of AFPM motor is different. For minimum torque ripple, angle of two rotor of AFPM motor are investigated. For this study, we used to Maxwell EM 3D program. A prototype AFPM motor have been assembled and driving power supply are made. Characteristics of magnetical and electrical characteristic are investigated.

  • PDF

미소 전극 간격을 갖는 방전장치에서의 방전특성 연구 (The study of the characteristics of micro-gap discharge)

  • 서정현;신범재;정희섭;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-269
    • /
    • 1994
  • Various types of plasma display panels(PDPs) have been developed to realize the flat panel display device. But, many of its characteristics must be improved before it can be commercialized. In order to investigate tile characteristics of micro discharge in a PDP ceil, we have constructed a micro-gap discharge system whose electrode gap can be adjustable between $100-1000{\mu}m$ within $0.1{\mu}m$ accuracy. We measured the minimum sustain voltage, current, delay time of discharge while changing parameters(electrode gap distance, electrode surface area, pressure) which influence discharge characteristics.

  • PDF

동저항 특성을 이용한 저항 스폿 용접기의 정전력과 정전류의 혼합모드 제어 (Mixed Mode Control of Constant Power and Constant Current for Resistance Spot Welder using Dynamic Resistance Characteristics)

  • 강성관;정재헌;노의철
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1571-1577
    • /
    • 2015
  • A new mixed mode control of constant power and constant current for resistance spot welding inverter is proposed to improve the weld quality. The conventional control scheme adopts constant current or constant power control mode, however, it is not easy to guarantee the high weld quality because of the nonlinear resistance characteristics of the welding point. The proposed method utilizes the nonlinear characteristics by measuring the dynamic resistance in real time. Therefore, it is possible for the welder to be controlled adaptively depending on the welding state. Experimental results show that the proposed control scheme improves the weld quality by 6.8 times compared with the conventional constant current mode control.

전극 간격에 따른 공기의 절연파괴 특성에 관한 연구 (A Study on the Electrical Breakdown Characteristics of Air according to Electrode Gap)

  • 강종오;이온유;김준일;방승민;이홍석;이종득;강형구
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.301-306
    • /
    • 2014
  • Recently in accordance with the rapid development of the industrial society, the accidents caused by dielectric breakdown have been increasing in power grid. It is important to prevent the dielectric breakdown of a high voltage apparatus to reduce the damage from electrical hazards. To establish an electrically reliable database of insulation design criteria for high voltage apparatus, a study on dielectric characteristics test is indispensable. In this study, dielectric characteristics according to field utilization factors (${\xi}$) which are represented as the ratio of mean electric field to maximum electric field are investigated. the dielectric breakdown experiments by using several kinds of electrode systems made with stainless steel are performed by AC breakdown voltage under air-insulation. Also, the experimental results are analyzed by the Weibull distribution. As a result, it is found that the dielectric characteristics of air-insulation are determined by ${\xi}$ as well as arrangement of electrode systems. It is considered that the results of this study would be applicable to designing the air-insulated high voltage apparatuses.

발변전용 피뢰기의 구조 및 ZnO 바리스터 소자의 전기적 특성 (Structure of Station Class Lightning Arresters and Electrical Characteristics of ZnO Varistor Blocks)

  • 조한구;한세원;이운용;윤한수;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1158-1161
    • /
    • 2004
  • This paper presents structural characteristics of station class lightning arresters and electrical characteristics of manufactured ZnO varistor blocks which are usable in those arresters. Three types of station class lightning arresters were investigated and those are a ceramic arrester, a FRP tube type polymer arrester, and a FRP rod type polymer arrester. Each arrester has merits and demerits with structural characteristics. In general, polymer arresters were made of silicon rubber for housing materials, FRP tube or rod for mechanical strength, ZnO blocks for electrical characteristics, and metal parts for electrical contact and the silicon rubber, the housing materials, was directly injected to the arrester module which was assembly composed of electrodes, ZnO blocks and FRP tube or rod, and to prevent the nonlinear electric fields distribution on upper parts of arresters, the grade ring was adopted to the upper electrodes. The reference voltage, nonlinear coefficient, residual voltage, and voltage ratio of manufactured ZnO varistors are 4.90kV, 50, 9.54kV, 1.94, respectively. Compared to designed electrical characteristics, the reference voltage was low for 600v and the voltage ratio was slightly high. However, the characteristics of discharge withstand was so excellent that the mechanical destruction does not occur at the impulse current of $8/20{\mu}s$ 10kA for 100 times.

  • PDF