• Title/Summary/Keyword: Electrical breakdown voltage

Search Result 1,206, Processing Time 0.029 seconds

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1735-1743
    • /
    • 2016
  • Insulation of valve-side windings in converter transformer withstands pulsating voltages, which will produce more serious insulation problems. In this paper, the electric breakdown experiments of oil-paper insulation specimens were executed at pulsating voltages and different temperatures. Experiment and analysis results showed that the breakdown voltage decreased with increasing temperature under pulsating voltage. The influence of temperature proves to be more significant once the temperature exceeds a limitation threshold. A fitting formula between breakdown voltage and the temperature was reported. Finally, in order to clearly understand the breakdown properties under pulsating voltage, the electric field distribution and space charge behavior under pulsating voltage at different temperature were discussed.

Study on 3.3 kV Super Junction Field Stop IGBT According to Design and Process Parameters (설계 및 공정 파라미터에 따른 3.3 kV급 Super Junction FS-IGBT에 관한 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.210-213
    • /
    • 2017
  • In this paper, we analyzed the structural design and electrical characteristics of a 3.3 kV super junction FS IGBT as a next generation power device. The device parameters were extracted by design and process simulation. To obtain optimal breakdown voltage, we researched the breakdown characteristics. Initially, we confirmed that the breakdown voltage decreased as trench depth increased. We analyzed the breakdown voltage according to p pillar dose. As a result of the experiment, we confirmed that the breakdown voltage increased as p pillar dose increased. To obtain more than 3.3 kV, the p pillar dose was $5{\times}10^{13}cm^{-2}$, and the epi layer resistance was $140{\Omega}$. We extracted design and process parameters considering the on state voltage drop.

Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor (고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.

Insulation Breakdown Properties of AC and DC according to Curvature Variation of PAI Organic/Inorganic Hybrid Coils (PAI 유/무기 하이브리드코일의 곡률변화에 따른 AC 및 DC 절연파괴 특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1721-1726
    • /
    • 2016
  • 4-types of coils were prepared by coating with polyamideimide (PAI) organic/inorganic hybrid. One type was made with original PAI vanish and the other 3-types were made of double layers, that was to say, high flexural PAI layer and high anti-corona PAI/nanosilica (15 wt%) layer. Drying temperature (T/D) were $220^{\circ}C$, $240^{\circ}C$, and $260^{\circ}C$, respectively and rectangular type coil for high-voltage rotating machine was used. DC and AC electrical breakdown tests were carried out in order to study the insulation properties according to T/D temperature and coil curvature (5, 15, and $25mm{\Phi}$). As the curvature increased, electrical breakdown voltage decreased and as T/D temperature decreased, electrical breakdown voltage increased.

A Study on the Design and Electrical Characteristics Enhancement of the Floating Island IGBT with Low On-Resistance

  • Jung, Eun-Sik;Cho, Yu-Seup;Kang, Ey-Goo;Kim, Yong-Tae;Sung, Man-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.601-605
    • /
    • 2012
  • Insulated Gate Bipolar Transistors(IGBTs) have received wide attention because of their high current conduction and good switching characteristics. To reduce the power loss of IGBT, the onstate voltage drop should be lowered and the switching time should be shortened. However, there is trade-off between the breakdown voltage and the on-state voltage drop. The FLoatingIsland(FLI) structure can lower the on-state voltage drop without reducing breakdown voltage. In this paper, The FLI IGBT shows an on-state voltage drop that is 22.5% lower than the conventional IGBT, even though the breakdown voltages of each IGBT are almost identical.

The Develop of Super Junction IGBT for Using Super High Voltage (대용량 전력변환용 초접합 IGBT 개발에 관한 연구)

  • Chung, Hun-Suk;Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.496-500
    • /
    • 2015
  • This paper was proposed the theoretical research and optimal design 3000V super junction NPT IGBT for using electrical automotive and power conversion. Because super junction IGBT was showed ultra low on resistance, it was structure that can improve the thermal characteristics of conventional NPT IGBT. The electrical characteristics of super junction NPT IGBT were 2.52 V of on state voltage drop, 4.33 V of threshold voltage and 2,846 V breakdown voltage. We did not obtaing 3,000 V breakdown voltage but we will obtain 3,000 V breakdown voltage through improving p pillar layer. If we are carried this research, This device will be used electrical automotive, power conversiton and high speed train.

Breakdown Properties of Coolant for HTS Apparatus Operating at Cryogenic Temperature

  • S.M. Baek;J.M. Joung;Kim, S.H
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.52-55
    • /
    • 2003
  • For the dielectric insulation design of any high temperature superconducting (HTS) apparatus in the electrical power systems, the breakdown properties of cryogenic coolants such as $LN_2$ are an important factor of the insulating engineering. Therefore, this paper presented an experimental investigation of breakdown phenomena in $LN_2$ under AC voltage. And we studied the breakdown properties of LN2 with decreasing temperature. Also, the Weibull plots of the breakdown voltage of subcooled $LN_2$ at 65 K for the needle-plane electrode with electrode distance d= 10 mm are studied. The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated. The experimental data suggested that the breakdown voltage of L$N_2$ depend strongly on the temperature of $LN_2$. The breakdown characteristics of $LN_2$ under quasi-uniform and non-uniform electrical field for temperature ranging from 77 K to 65 K were clarified.

The Breakdown Characteristics due to Particles in GIS Chamber (모의 GIS 내에서 파티클의 재질에 따른 절연파괴 특성)

  • 이재걸;곽희로;이강수;김경화;조국희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.67-69
    • /
    • 1997
  • Abstract - In this paper, the behaviour and effect of various particles made of conducting wires( Fe, Cu, Al ) in a SF6 insulated electrode system, are presented. It is shown that the ac breakdown voltage of compressed SF6 is influenced by different conducting particles. The breakdown voltage due to the particle is dependent of a class of particle. The breakdown voltage due to Cu particle was the highest and the breakdown voltage due to Al particle was the lowest.

  • PDF

A Novel IGBT with Double P-floating layers (두 개의 P-플로팅 층을 가지는 새로운 IGBT에 관한 연구)

  • Lee, Jae-In;Choi, Jong-Chan;Yang, Sung-Min;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.14-15
    • /
    • 2009
  • Insulated Gate Bipolar Transistor(IGBTs) are widely used in power device industry. However, to improve the breakdown voltage, IGBTs are suffered from increasing on-state voltage drop due to structural design. In this paper, the new structure is proposed to solve this problem. The proposed structure has double p-floating layer inserted in n-drift layer. The p-floating layers improve the breakdown voltage compared to conventional IGBT without change of other electrical characteristics such as on-state voltage drop and threshold voltage. this is because the p-floating layers expand electric field distribution at blocking state. A electrical characteristic of proposed structure is analyzed by using simulators such as TSUPREM and MEDICI. As a result, on-state voltage drop and threshold voltage are same to a conventional TIGBT, but breakdown voltage is improved to 16%.

  • PDF

A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses (고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.