• 제목/요약/키워드: Electrical arc-discharge

검색결과 170건 처리시간 0.027초

고압 수은방전의 교류 아아크 모델에 관한 연구 (A Study on the AC Arc Model of High Pressure Mercury Discharge)

  • 지철근;김훈;이상우
    • 대한전기학회논문지
    • /
    • 제36권9호
    • /
    • pp.655-659
    • /
    • 1987
  • This study presents a model of the electrical characteristics of the high-pressure mercury vapour arc discharge. Energy balance equation per unit volume of the arc tube is converted into the one per unit length by assuming the parabolic radial temperature distribution and integrating over the cross-section of the tube. Using this energy balance equation, together with the circuit equation and Ohm's law, the arc voltage and current variation for 1 cycle is numerically calculated and a good result is obtained. A simple method to calculate the axis temperature of the arc tube and the radiation output is also presented.

  • PDF

감쇠파 고주파전압의 선행방전을 이용한 Plasma jet의 전기적 기동특성에 대한 실험적 연구 (The Experimental Research On The Electrical Characteristics For The Ignition Of Plasma Jet Using The Advance Discharge Of High Frequency Voltage With Attenuation)

  • 전춘생
    • 전기의세계
    • /
    • 제21권4호
    • /
    • pp.27-38
    • /
    • 1972
  • This paper discusses the characteristics about the ignition of D.C. main discharge is a plasma jet generator, manufactured for trial as non-transferred type, when the electrical energy appropriate to the ignition is supplied to the gap between the electrodes by using advance discharge of attenuating high frequency voltage generated by a high frequency oscillator with mercury spark gap. These characteristics are under the influences of (a) the length of mercury gap in high frequency oscillator and the quantity of hydrogen flow supplied to it, (b) the condenser capacity of the high frequency oscillator circuit, (c) the length of plasma jet torch in D.C. main discharge circuit and the quantity of argon flow supplied to it, (d) the circuit constants of D.C. main discharge circuit. The results for these characteristics, obtained by this research, are considered to be helpful to the designs for the ignition of a plasma jet as well as the welding arc stabilizer by high frequency discharge and the high frequency arc welder.

  • PDF

보강제 변화에 따른 실리콘 고무의 트래킹 열화 특성에 관한 연구 (A Study on Tracking Degradation Properties of Silicone Rubber due to Reinforcing Agent)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제27권12호
    • /
    • pp.841-846
    • /
    • 2014
  • It found that the maximum temperature of the arc discharge occurred on the Silicone rubber sample significantly decreased with increasing the reinforcing agent. It was confirmed that the current value decreased with increasing the aluminium trihydrate($Al(OH)_3$) and the current value increased with reducing the primary resistance over time. Regarding these results, may be it is because the degradation due to the electro-conductive carbonization was improved and the properties of dielectric breakdown was reduced by the flame retardant reinforcing agent. It found that the electro-conductive carbonized road has not happened by increasing the flame retardant reinforcing agent. Regarding to the arc discharge, this study show that the arc arising near the lower electrode of sample has disappeared.

원격감시 기능을 갖는 고감도 부분방전센서 (Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities)

  • 최규남
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.349-356
    • /
    • 2015
  • 광학적 잡음과 전기적 잡음을 복합적으로 제거할 수 있는 하이브리드 필터를 채용하고 펄스형태의 아크 광 신호를 적분하여 수신되는 아크에너지의 크기로 감지할 수 있는 원격감시 기능을 갖는 고감도 부분방전 센서를 구현하였다. 하이브리드 필터는 부분방전 센서가 설치되는 배전반 내 환경에서 내부 형광등과 백열등 조명에 대하여 영향을 받지 않음을 보여주었다. 종래에는 아크광의 불규칙한 파형특성으로 인하여 첨두치가 감지되어 아크광의 크기에 비례한 선택적 감지가 어려웠으나, 센서에 적용된 적분연산 기능은 각기 다른 아크광의 에너지 레벨에 대하여도 선택적으로 감지가 가능함을 실험적으로 보여주었다. 센서는 2m 이격된 원격지에서 100A 저압 MCCB의 정상 개폐 시 발생하는 섬광에 해당하는 광 에너지에 대해서도 감지가 가능함을 보여주어 원격감시 기능을 갖는 고감도 부분방전센서에 적용 가능함을 보여주었다.

전기화재 방지를 위한 AFCI 알고리즘 설계 (AFCI algorithm design for electrical fire protection)

  • 반기종;최성대;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1769-1770
    • /
    • 2006
  • Arc Fault is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional interrupter does not have the arc current interrupt function. Hence, Arc fault circuit interrupter controller is designed for the interruption of arc fault current which has the modified arc characteristics.

  • PDF

전기화재 방지를 위한 아크고장전류 차단기 설계 (Arc Fault Circuit Interrupter Design for Electrical Fire Protection)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권5호
    • /
    • pp.220-225
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc fault circuit interrupter does not have the arc current interrupt function. Hence, Arc current controller is designed for the interruption of arc fault current which has the modified arc characteristics.

코로나와 직렬아크 방전에 의해 발생한 음향신호의 분석 (Analysis of Acoustic Signals Produced by Corona and Series-arc Discharges)

  • 조향은;진창환;박대원;길경석;안창환
    • 한국전기전자재료학회논문지
    • /
    • 제25권2호
    • /
    • pp.147-152
    • /
    • 2012
  • This paper dealt with the frequency component analysis of acoustic signals produced by corona and series-arc discharges as a diagnostic technique for closed-switchboards. Corona and series-arc discharge were simulated by a needle-plane electrode and an arc generator specified in UL1699, respectively. Acoustic signal was detected by a wideband acoustic sensor with a frequency bandwidth of 4 Hz~100 kHz (-3 dB). We analyzed frequency spectrums of the acoustic signals detected in various discharge conditions. The results showed that acoustic signals mainly exist in ranges from 30 kHz to 60 kHz. From the experimental results, an acoustic detection system which consists of a constant current power supply (CCP), a low noise amplifier (LNA) and a band pass filter was designed and fabricated. The CCP separates the signal component from the DC source of acoustic sensor, and the LNA has a gain of 40 dB in ranges of 280 Hz~320 kHz. The high and the low cut-off frequency are 30 kHz and 60 kHz, respectively. We could detect corona and series-arc discharges without any interference by the acoustic detection system, and the best frequency is considered in ranges of 30 kHz~60 kHz.

세라믹 메탈할라이드 램프의 아크튜브 구조에 따른 광학적 특성 (Optical Properties with Arc Tube Structure of Ceramic Metal-Halide Lamps)

  • 김우영;장혁진;양종경;박형준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.378-379
    • /
    • 2009
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

  • PDF

직렬아크 방전의 주파수 스펙스럼 분석

  • 김선재;정광석;박대원;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.24-24
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of electromagnetic waves which is generated by series arc discharges to develop a condition monitoring technique in a closed-distribution board. We fabricated an arc generator specified in UL1699 to simulate series arc discharge. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of a Ultra Log Antenna and a EMI Test Receiver. The results showed that the frequency spectrum during series arc discharges was distributed in ranges of 30~500 [MHz], and the peak values were existed at 40 [Mhz] and 80 [MHz].

  • PDF

세라믹 메탈할라이드 램프 아크튜브 구조에 따른 광학적 특성 (Optical Properties with Arc Tube Structure of Ceramic Metal Halide lamps)

  • 이주호;양종경;김남군;장혁진;박대희
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2244-2248
    • /
    • 2008
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.