• Title/Summary/Keyword: Electrical apparatus

Search Result 694, Processing Time 0.024 seconds

A Study for Designing of Intelligent Lighting Control LED Apparatus (지능형 조명 제어 시스템용 LED 단말기 개발)

  • Yoo, Soo-Yeub;Lee, Gi-Heon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.101-104
    • /
    • 2008
  • This paper is a report of designing for LED lights driver unit. The main purpose of driver designing is high electrical efficient performance and intelligent control LED driver. This LED driver can be used for intelligent light control. This product expects to improve the light control by dimming instead of interlace on/off light control that increases the social cost such as car accidents and etc.

  • PDF

A Functional Electrical Stimulation System Employing a V40 Microprocessor for Paralyzed Extremities (V40 마이크로프로세서를 이용한 마비기능복원용 전기자국장치의 개발)

  • 임영철;류영재;김이곤;조경영;박철수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.679-686
    • /
    • 1994
  • This paper describes an improved FES system to restorp paralyzed extremities in spinal-cord-injured patients. By using time-division method in the proposed FES system, we can reduce the size and weight of system despite of increasing channels. We designed a DC-DC converter to adapt the condition of each patient. We could reduce the cost by using easily available apparatus like an IBM-PC for the stimulus-pattern-creating system and standardized parts for the protable FES system.

Pitch Control Simulation of Horizontal Wind Power System (수평축 풍력발전시스템의 피치제어 시뮬레이션)

  • Hwang, Sung-Joon;Seo, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.846-848
    • /
    • 2000
  • In the early development of wind energy, the majority of wind turbines were operated at constant speed. Recently, the number of variable-speed wind turbines adopted pitch control apparatus has increased. This paper deal with a simulation of pitch control of variable-speed wind turbine and the response of pitch angle is traced in a given random wind speed.

  • PDF

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

The Auxiliary Power Compensation apparatus for small scale Photovoltaic/Wind Hybrid Generation System (중소형 태양광/풍력 복합발전시스템의 보조 전력보상장치에 관한 연구)

  • Park Se-Jun;Yoon Jeong-Phil;Yoon Hyung-Sang;Lim Jung-Yeol;Kang Byung-Bog;Lee Jeong-Il;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.109-112
    • /
    • 2004
  • Photovoltaic energy and wind energy are very in constant depending on the season, time and extremely intermittent energy sources. Because of these reasons, in view of the reliability the solar and the wind generation system have many problems(energy conversion, energy storage, load control etc.) comparing with a conventional power plant. So, in order to solve these existing problems, hybrid generation system of photovoltaic(500W) and wind power(400W), which combines wind power energy and solar energy to have effect of supporting each other, was suggested. But hybrid generation system cannot always generate stable output with weather condition, the auxiliary power compensation apparatus that uses elastic energy of spiral spring to hybrid generation system was also added for the present study. And it may confirm that power was continuously provided to load by storing energy obtained from generating rotary energy of spiral spring generates in small scale generator.

  • PDF

Electrical characteristics of Engineering Polymer (Engineering Polymer의 전기적 특성)

  • Park, Jae-Yeol;Park, Sung-Hee;Kwon, Oh-Deok;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.235-238
    • /
    • 2003
  • Thermo-plastic has generally bad electrical characteristics at high temperature comparing to thermoset-plastics when the plastic apply to electrical power apparatus as an electrical insulator. To solve the problem, we study engineering plastics such as Polyamide and Polyphthalamide as a base resin. And filler of the engineering plastics is glass fiber. Electrical characteristics studied are permittivity, loss factor and breakdown strength according to temperature and frequency of measuring signal. Electrical characteristics of Polyphthalamide has good temperature and frequency dependency comparing to those of Polyamide.

  • PDF

Development of Arc Fault Interruption Control Circuit of Fault Voltage Sensing Type (사고전압 감지형 아크차단 제어회로 개발)

  • Kwak, Dong-Kurl;Byun, Jae-Ki;Lee, Bong-Seob
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.1-5
    • /
    • 2013
  • This paper studies on an arc fault interruption control circuit (AFICC) of fault voltage sensing type. The proposed voltage sensing type AFICC (VST_AFICC) is an electrical fire prevention apparatus that operates the existing circuit breaker with sensing the instantaneous voltage drop of line voltage when occurs electrical faults. The existing Earth Leakage Circuit Breaker (ELB), Molded_case Circuit Breaker (MCCB), and Residual Current Protective Devices (RCDs) used in low voltage distributing system don't have protective capability from electric arc faults to be a major factor of electrical fire. In this paper to improve such problems, a new VST_AFICC using the distortion of voltage waveform when occurs electrical faults is proposed to prevent electrical fire. There is characteristic that the control method of proposed apparatus is different from previous current sensing type. The proposed AFICC has merit that is manufactured by small size and light weight. The practicality of a new VST_AFICC is also verified through various operation analysis.

A Study on the Signal Propagation Characteristics of Generator Windings (발전기 권선에서의 신호전송 특성에 관한 연구)

  • Hwang, Don-Ha;Kim, Jin-Bong;Kim, Yong-Joo;Park, Myong-Soo;Kim, Taek-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1299-1303
    • /
    • 1995
  • The detection and measurement of partial discharge activity prevalent in the solid insulating systems of high-voltage generator stator windings has, for many years, been a recognized method of assessing the insulation condition of such systems. Partial discharge activity occurs at sites of degradation within, or at the surface of, stator's insulation systems under high voltage stressing. However, partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. The mode of transmission varies with the signal frequency and is dependant on the geometrical configurations of windings. This paper reports the investigated results of the signal propagation characteristics along the windings when both sinusoidal signals and simulated partial discharge pulses are injected at the various positions of stator windings within the 25 MVA, 11 kV hydro generator. The on-line identification technique of partial discharge location in generator windings is also proposed in this study.

  • PDF

Isolated Working Canine Heart Perfusion Apparatus for Evaluation of Myocardial Protection Methods (심장기능 평가를 위한 견 적출심장 관류장치의 설계)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.246-253
    • /
    • 1988
  • An in vitro model providing with a recirculating perfusion apparatus using an isolated canine heart and its autogenous blood, which was prepared for study of myocardial protection method. This apparatus was easily used by quick connect system and maintained well heart function for about 2 hours. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at 37` into the aorta from aortic reservoir located 100 cm above the heart. The isolated perfused working canine heart model was a left heart preparation in which oxygenated perfusion medium [at 37K] entered the cannulated left atrium at a constant flow rate [900ml/ min] under 20 mmHg overflow system and was spontaneously ejected[no electrical pacing] via an cannula against a hydrostatic pressure of 80 cm H2O. During this working period, various indices of cardiac function were measured. The cardiac functions were stable for over 2 hours with perfusion of Krebs-Henseleit solution and autologous blood[1:1] mixture in volume and maintained heart rate ]]3-122/bpm peak systolic pressure 109-113 mmHg, cardiac output 900 ml / min and left atrial mean pressure 8-9 mmHg. In this model, the efficiency of myocardia] protection could be easily measured by means of functional, enzymatic, biochemical and ultrastructural assessment. And also, we believe this model to be a useful assessment screening model of recovery state after long duration of myocardial preservation of donor heart without difficult transplantation procedures.

  • PDF

A study on measurement apparatus for ferroelectricity in ferroelectrics (강유전특성 측정장치의 연구개발)

  • Lee, Chang-Hun;Kang, Dae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1317-1319
    • /
    • 1997
  • This paper is to study and develope a measurement apparatus for ferroelectricity. The apparatus consists of wave generation part, high voltage amplifier part, measurement part, data acquisition part and the related controll circuits. Single or double excitation wave is digitalized and sent to the external RAM of wave generation part by personal computer. These datas saved in the RAM are converted to analog excitation wave through D/A converter. The frequency of excitation wave is depend on the read-out speed of the RAM by clock pulse. Such generated wave is applied to high voltage amplifier as a input voltage. The output of high voltage amplifier is applied to ferroelectrics and the response is obtained from the charge amplifier of measurement part. The response is sampled and converted to digital datas through AID converter. These digital datas are automatically saved in the external RAM of acquisition part. The computer takes the digital datas and calculates the electric displacement D, the electric field and the dielectric constant $\varepsilon$. We tested for PZT ceramic sample and could observed the D-E hysteresis lops and ${\varepsilon}_s$-E hysteresis loops with good forms.

  • PDF