• Title/Summary/Keyword: Electrical apparatus

Search Result 694, Processing Time 0.03 seconds

Design and Analysis of an Axial Flux Magnet for Magnetic Levitation System. (자기부상용 증축형 전자석의 설계 및 특성 해석)

  • Kang, Do-Hyun;Shin, Pan-Seok;Kim, Yong-Joo;Cho, Yun-Hyun;Park, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.63-67
    • /
    • 1990
  • An axial flux magnet for a magnetic levitation system is designed and analysed by finite element simulations. The results are compared with those of experiment in order to verify the analysing method. Lift force, air gap flux density and temperature characteristics of the magnet showed fairly good agreement with each other.

  • PDF

Measurement of the Effective Thermal Conductivity of Porous Media in the Mockup Apparatus of Reactor Vessel (원자로 모의 다공질 매체의 유효 열전달 계수 측정)

  • 김용균;황종선;이용범;최석기;남호윤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.447-450
    • /
    • 1997
  • Temperature distribution measurements in the mockup apparatus of reactor vessel were performed to determine the effective thermal conductivity of Al powder porous media where stainless steel tubes were installed with different geometry. The temperature distributions at four separated sections with different arrangements of porous media have different slopes according to the geometrical configuration. From the measured temperature distribution, effective thermal conductivity have been derived using the least square fitting method.

  • PDF

Development of A Test Apparatus for Control Rod Drive Mechanism in Nuclear Power Plants

  • Kim, Choon-Kyung;Cheon, Jong-Min;Lee, Jong-Moo;Kim, Seog-Joo;Kwon, Soon-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1732-1735
    • /
    • 2003
  • In this paper, a DSP-based test apparatus for Control Rod Drive Mechanism (CRDM) that is used in nuclear power plants is described. Using this apparatus, we can test the mechanical and electrical characteristics of CRDM and obtain some information about how to improve the CRDM further and how to design a power controller to actuate the CRDM. Since firing angles can be directly applied to the gate-drive circuits of thyristors in the power controller by using this apparatus, the maximum and minimum values of firing angles within available limits are easily measured. Also step-current inputs help us investigate each coil's response characteristics. Therefore, we can easily find the range of control gains which enables a stable CRDM operation in insertion and withdrawal actions at high speed, mid speed, and low speed. Since this apparatus has a test mode in which an insertion or withdrawal action is divided into several phases so that the current command for each phase is given step by step, we may judge whether the CRDM works as expected or not. We also describe a fault detection capability of the test apparatus for the power controller by using discrete Fourier transform.

  • PDF

Influence upon electrical properties of outdoor insulators with non-uniformity contamination (국부오손이 옥외절연물의 전기적 특성에 미치는 영향)

  • 이원영;최남호;박강식;한상옥
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.203-206
    • /
    • 2001
  • Since th three sides of korea peninsula are surrounded by the sea, electric apparatus are greatly contaminated by the salt generated by the typhoon, seasonal wind, sea wind and sea fog. This contamination causes electric power apparatus to fail. Thus in this paper, we investigated to influence upon electrical properties of outdoor insulators with non-uniformity contamination in the experimental condition because The contamination of outdoor insulator highly depended wind property In the service condition, insulator was not uniformly contaminated. From the flashover test for the 254 mm suspension insulator, we could determine the influence non-uniform contamination on the electrical property of insulators. Through the experiment, we convinced to occur flashover from non-uniform contamination region of outdoor insulator. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

Electromagnetic Field Analysis Using the Point Collocation Method Based on the FMLSRK Approximation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Park, Kyong-Yop;Kim, Do-Wan
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.180-183
    • /
    • 2004
  • This paper presents a description of the point collocation method and its application to the electromagnetic field computation. The interpolation scheme is based on the fast moving least square reproducing kernel approximation. In the method, the integration cell is not required and the essential boundary conditions can be enforced directly. Numerical simulations on 1-D and 2-D problems are carried out to validate the method. It is found that computational efficiency is higher than the general mesh-free methods.