• 제목/요약/키워드: Electrical activity

검색결과 870건 처리시간 0.032초

다중채널 EEG 신호의 Computerized BEAM 구현 (Implementation of Computerized BEAM for Multi-Channel EEG Signals)

  • 이건기;김영일;한석봉;신태민;신상진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.156-159
    • /
    • 1993
  • In this paper, computerized BEAM (brain electrical activity map) was implemented for objective and quantitative multichannel EEG analysis. BEAM is calculated by 4 point Interpolation method and number of elements are 5140. Representation methods of BEAH are two. One is dot density method which classify brain electrical potential 9 levels by dot density and the other is color method which classify brain electrical 12 levers by different colors. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily.

  • PDF

전기 자극을 이용한 피드백의 형태가 무릎성형 수술 환자의 넙다리 네갈래근 등척성 운동 학습에 미치는 영향 (Effects of Electrical Stimulation Biofeedback on Motor Learning of Quadriceps Isometric Exercise of Total Knee Replacement)

  • 박은영;곽창화;정경수
    • 한국전문물리치료학회지
    • /
    • 제7권3호
    • /
    • pp.81-89
    • /
    • 2000
  • The purpose of this study was to determine the effect of electrical stimulation biofeedback on motor learning of quadriceps muscle isometric exercise in 3 patients who have undergone total knee replacement surgery. A multiple baseline design across subjects was used. The electrical stimulation biofeedback was provided with each patient during quadriceps isometric exercise, which last 10 to 14 sessions with 10 repetitions each sessions. After training patients received 4 retention tests. Maximum muscle activity was measured pre- and post- electrical stimulation biofeedback training and retention test to evaluate the effect of biofeedback training. Maximum isometric muscle activity of quadriceps was increased after electrical stimulation biofeedback training in all subjects. The results indicate that a electrical stimulation biofeedback training is a useful method to improve motor learning of quadriceps isometric exercise in total knee replacement.

  • PDF

기능적 전기 자극을 이용한 생체되먹임 융합 자세조절 훈련이 뇌졸중 환자의 근활성도와 균형 능력에 미치는 영향 (The Effects of Biofeedback Fusion Postural Control Training using Functional Electrical Stimulation on the Muscle Activity and Balance Ability of the Stroke Patient)

  • 김제호;엄요한
    • 디지털융복합연구
    • /
    • 제17권12호
    • /
    • pp.319-327
    • /
    • 2019
  • 본 연구에서는 기능적 전기 자극을 이용한 생체되먹임 융합 자세조절 훈련을 중재하여 급성기 뇌졸중 환자들의 다리 근활성도와 균형 능력에 미치는 효과에 대하여 알아보고자 하였다. 뇌졸중 환자는 기능적 전기 자극을 이용한 생체 되먹임 융합 자세조절 실험군 15명과 일반적인 생체되먹임 융합 자세조절 대조군 15명으로 나누어 8주간 주 5회, 30분간 시행하였고, 다리 근활성도를 평가하기 위해 근전도를 이용하여 가쪽넓은근, 안쪽넓은근, 넙다리곧은근, 넙다리두갈래근를 측정하였다. 균형 능력을 측정하기 위해 Biorecue를 이용하여 균형 능력을 측정하였다. 다리 근활성도 비교에서는 가쪽넓은근, 안쪽넓은근, 넙다리곧은근, 넙다리두갈래근에서 통계적으로 유의한 차이를 보였고, 균형 능력 비교에서는 신체 중심 이동면적, 총 궤적 길이, 안정선한계에서 통계적으로 유의한 차이를 보였다. 이에 따라 기능적 전지 자극을 이용한 생체되먹임 자세조절 훈련이 일반적인 생체되먹임 자세조절 훈련 보다 다리 근활성도와 균형 능력을 향상시키는데 효과적임을 알 수 있었다.

3축-가속도 센서를 이용한 배례(拜禮)동작 모니터링 및 자동검출 시스템 설계 (Design of Bowing-Activity Monitoring and Automatic Detection System Using 3-Axis Accelerometer)

  • 이영재;이필재;차지영;선우섭;황진상;이정환
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1150-1158
    • /
    • 2010
  • In this paper, a new reliable portable activity monitoring device implemented with the buddhist-style bowing activity and walking step detection algorithm, is presented. In order to monitor the bowing and walking activities, miniaturized 3-axis accelerometer sensor with the sensitivity of 800 mV/g was used. After initial signal conditioning, vector magnitude of accelerometer signals was calculated. Syntactic peak detection method was used in order to feature points. All signal processing algorithms were implemented in ultra-low power microcontroller MSP430 with double precision floating point arithmetic. For evaluation, 19 young man($24.22\pm5.22$ yrs) and woman($22.28\pm2.72$ yrs) were involved. The accuracy of the proposed algorithms were 98.91 %($\pm0.011$) for walking step detection and 98.25 %($\pm0.023$) for buddhist-style bowing activity. Comparing to the commercialized pedometer accuracy, 87.1 %($\pm0.058$), the proposed walking step detection algorithms show more reliable accuracy.

Changes in Vestibular Nerve Activity Following Acute Hypotension in Rats

  • Park, Byung-Rim;Kim, Min-Sun;Yee, Gue-Hyun;Moon, Myoung-Jin;Kim, Jae-Hyo;Jin, Yuan-Zhe;Kim, Yo-Sik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제7권2호
    • /
    • pp.85-89
    • /
    • 2003
  • The basic mechanism for the excitation of the peripheral vestibular receptors following acute hypotension induced by sodium nitroprusside (SNP) or hemorrhage was investigated in anesthetized rats. Electrical activity of the afferent vestibular nerve was measured after pretreatment with kynurenic acid, an NMDA receptor antagonist. The activity of the vestibular nerve at rest following acute hypotension induced by SNP or simulating hemorrhage was a greater increase than in control animals. The gain of the vestibular nerve with sinusoidal rotation following acute hypotension increased significantly compared to control animals. The acute hypotension induced by SNP or hemorrhage did not change the activity of the afferent vestibular nerve after kynurenic acid injection. These results suggest that acute hypotension produced excitation of the vestibular hair cells via glutamate excitotoxicity in response to ischemia.

적출한 고양이 위(胃)의 전기활동에 미치는 prostaglandin $E_2$ 및 indomethacin의 영향 (Effect of Prostaglandin $E_2$ and Indomethacin on Electrical Activity of Isolated Cat Stomach)

  • 김명석;이윤렬
    • The Korean Journal of Physiology
    • /
    • 제17권1호
    • /
    • pp.63-69
    • /
    • 1983
  • This study was conducted to investigate the effect of prostaglandin $E_2(PGE_2)$ and indomethacin upon the electrical activity of the isolated cat stomach muscle strips$(1.5{\times}7.0\;cm)$. Fifty-seven muscle strips, obtained from 57 cat stomachs(including corpus and antrum) were studied in a muscle chamber filled with Krebs solution(pH 7.4, temperature $36{\pm}0.5^{\circ}C$) aerated with 5% $CO_2$ in $O_2$. The electrical activity was recorded by five capillary electrodes (Ag-AgCl), of which two were placed on the corpus and three on the antrum. After recording of the electrical activity in normal Krebs solution, $PGE_2$ in concentrations of 0.25(N=7), 0.5(=7), 1(N=7) and $2{\times}10^{-7}\;M(N=6)$ were administered to 27 muscle strips, while indomethacin was applied in concentretions of 0.25(N=9), 0.5(N=10), 1(N=6) and $2{\times}10^{-3}\;M(N=5)$ to the remaining 30 strips. The mean frequency were minutely measured from each electrogastrogram. 1) By adding $PGE_2$ in all doses, gastric slow wave frequency increased significantly compared with that in resting state. 2) Following $PGE_2$ administration, peak slow wave frequency increased dose-dependently. 3) After indomethacin addition in all doses, the slow wave frequency decreased significantly compared with that in resting state. 4) Following indomethacin administration, incidence of complete abolition of slow wave increased dose-dependently, and its latent period decreased also in a dose-dependent manner. It is inferred from the above results that prostaglandin $E_2$ has a facilitatory role in the development of gastric slow wave in cat.

  • PDF

권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가 (Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines)

  • 강동식;김용주;윤영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

심전도 자동 진단 알고리즘 및 장치 구현(III) - 심방 및 심실활동 검출기 (An implementation of automated ECG interpretation algorithm and system(III) - Detector of atrium and ventricle activity)

  • 권혁제;이정환;윤지영;최성균;이준영;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.288-292
    • /
    • 1996
  • This paper describes far the detection of heart event that is, QRS complex and P wave which are result from heart activity. The proposed QRS detection method by using the spatial velocity was identified as having the 99.6% detection accuracy as well as fast processing time. Atrial flutter, coupled P wave, and noncoupled P wave as well as atrial fibrillation could be detected correctly by three different algorithms according to their origination farm. About 99.6% correction accuracy coupled P wave could be obtained and we could be found that most detection errors are caused by establishing wrong search interval.

  • PDF

전기전도도 시험방법을 활용한 산업부산물 포졸란재료의 반응성 평가 (Evaluation on Reactivity of By-Product Pozzolanic Materials Using Electrical Conductivity Measurement)

  • 최익제;김지현;이수용
    • 한국건축시공학회지
    • /
    • 제16권5호
    • /
    • pp.421-428
    • /
    • 2016
  • 본 연구에서는 전기전도도 시험방법을 이용하여 다양한 산업부산물재료의 포졸란 반응성을 평가할 수 있는 대안을 제안하고자 하였다. 실험에 사용된 재료는 일반적으로 포졸란 재료로 활용되고 있는 산업부산물 플라이애시(class F, C) 2종, 실리카퓸(densified, undensified) 2종, 메타카올린과 포졸란 반응성이 정량적으로 증명되지 않은 산업부산물인 벤토나이트, 그라스울, 세라믹을 활용하여 포졸란 반응성을 측정 하였다. 각 재료가 $40^{\circ}C$ 포화수산화칼슘 수용액에 침지된 이후의 전기전도도의 변화를 관찰하였으며, $450{\sim}500^{\circ}C$에서 관찰된 수산화칼슘의 분해량을 통해 포졸란 반응성을 교차 검증하였다. 28일 압축강도 또한 포졸란 반응에 의한 역학적 성능의 개선여부를 검증하기 위해 활용되었다. 실험결과에 따르면, 전기전도도 최대값과 4시간후의 전기전도도의 차이를 활용하여 포졸란 반응성을 평가하는 것이 적절하다고 나타났다. 이러한 방법을 활용할 경우 수산화칼슘 함유량에 근거한 포졸란 반응성 평가와 매우 유사한 결과를 얻을 수 있었으며, 28일 압축강도 측정을 통해 얻은 결과와도 큰 차이를 보이지 않아, 전기전도도 시험법이 포졸란 반응성이 증명되지 않은 재료의 포졸란 반응성평가에도 충분히 활용될 수 있는 것으로 나타났다.

착용형 심장활동 모니터링 시스템을 활용한 정신적 스트레스 평가 (The Assessment of Dynamic Mental Stress with Wearable Heart Activity Monitoring System)

  • 김경섭;신승원;이정환;최희정
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1109-1115
    • /
    • 2008
  • In the ubiquitous health monitoring environments, it is quite important not only to evaluate the physiological health condition but also mental stress condition. In order to achieve this goal, a heart activity monitoring system utilizing a wearable bipolar electrode is devised and the heart rate variability(HRV) is extracted and interpreted in both frequency and time feature domains. Consequently, to evaluate the emotional stress condition of the subjects, a stress-induced experimental protocol was applied to healthy subjects and the time and frequency features of heart activity were analyzed in terms of the ratio of low frequency components v.s., high frequency components and the relevant the moving average distributions compromising the successive RR peaks intervals in the ambulatory ECG measurement system.