• Title/Summary/Keyword: Electrical accident

Search Result 519, Processing Time 0.031 seconds

Safety Analysis of Potential Hazards at Hydrogen Refueling Station (수소충전소 잠재적 위험에 대한 안전성해석)

  • Park, Woo-Il;Kim, Dong-Hwan;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • This study was conducted using FLACS, a specialized gas accident analysis program. Hydrogen refueling stations subject of safety analysis, consist of compression facilities, storage tanks, and hydrogen piping. The safety analysis of potential risk factors was conducted after reflecting the design specifications of major facilities and components, environmental conditions around hydrogen refueling stations, etc. As of 2021, about 70 refueling stations in Korea are available, and 1,200 are scheduled to be introduced in the next 2040. To prepare for possible accidents caused by potential hazards for the safe distribution of hydrogen refueling stations, we intend to derive hydrogen leakage diffusion scenarios and review their safety.

Infrastructure of Propulsion Test Facility of Liquid Rocket (액체로켓 추진기관 시험설비 기반시설 고찰)

  • Cho, Namkyung;Kim, Sunghyuk;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.87-94
    • /
    • 2019
  • Liquid rocket propulsion test facility should provide for the interface condition installed on the upper level system for the test article. In addition, safety provision should be provided to be ready for accident such as explosion which can be occurred during development stage. For this purpose infra-structures of test facilities must be constructed so that stable combustion test can be performed and be guard against accidents. In this article, various aspects for infrastructures of propulsion test facilities are investigated including architecture and civil engineering aspects, test stand, room arrangements, interfaces among facilities, fire-fighting facilities, electrical power facilities.

Living Lab and Confusion Matrix for Performance Improvement and Evaluation of Artificial Intelligence System in Life Environment (생활 환경에서의 인공지능 시스템 성능 개선 및 평가를 위한 리빙랩 및 혼동 매트릭스)

  • Ha, Ji-Won;Seo, Ji-Seok;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1180-1183
    • /
    • 2020
  • Recently, the daily life safety detection functionalities such as fall accident detection and burn danger detection are widely disseminated along with the development of IoT and smart home. These safety detection functionalities are mostly performed by artificial intelligence. However, simple accuracy measurement of the safety detection in laboratory environment is often far from practical performance in daily life environment. To mitigate this problem, this paper introduces two techniques, i.e. living lab and confusion matrix. Living lab is more than simple simulation of daily life environment, and it enables users to directly participate technology development and product design. Various performance measures induced from confusion matrix significantly help to evaluate the performance of artificial intelligence system for proper application purposes.

Magnetic Field Simulation and Analysis for Monitoring Safety Hook Fastening (안전고리 체결 감지를 위한 자기장 시뮬레이션 및 분석)

  • Lee, Hoo-Sung;Heo, Jun;Park, Yong-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1169-1174
    • /
    • 2020
  • In this paper, in order to prevent a fall accident that occurs while working without fastening the safety hook at a construction site, a method to detect whether the safety hook is fastened using two coils is proposed. Ansys' Maxwell, an electromagnetic wave analysis simulator, was used to analyze the magnetic field before and after the safety hook fastening, and the possibility of confirming the fastening of the safety hook using the difference in the mutual inductance change and the resulting current induced in the receiving coil was shown.

The Cause Analysis and Research of Malfunction for Elevator Equipment of the Apartment House (공동주택의 승강기 설비에 대한 오동작 원인 조사 및 고찰)

  • Kim, Gi-Hyun;Bang, Sun-Bae;Kim, Chong-Min;Bae, Suk-Myong;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.65-71
    • /
    • 2006
  • The number of elevator installation increases every year about 15,000. The number of confine-disease of elevator increases every year and then sudden in, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction related life accident is increasing. Therefore we researched elevator repair diary of elevator repairing company, APT management office and 119 life rescue for elevator confine-disease during 2004. 1. 1.${\sim}$12. 31. we analyzed the content and the time type and cause of the malfunction and fault for APT elevator. Form the result of 119 life rescue, only power reset is 24[%] and only power failure is 8.2[%] by cause of confine-disease. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

Design and Implementation of Concentration Calculation Algorithm for the Infrared Combustible Gas Detector (적외선 가연성 가스검지기의 농도 산출 알고리즘의 설계 및 구현)

  • Han, Seungho;Lyu, Geunjun;Lee, Yeonjae;Kim, Hiesik;Park, Gyoutae
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.145-152
    • /
    • 2016
  • Recently, we can find news about toxic and combustible gas accident. So, we have to develop gas detector that can measure gas at dangerous area for preventing gas accidents. In this paper, we calculate a approximation function from sensor's output using the linear regressiong. And we develop software algorithm using Neville's algorithm for measuring gas concentration. Finally, we compare our algorithm with combustible gas detectors that are already developed, by using standard gas samples manufactured Korea Gas Safety. As a result of this experiment, we confirm that performance of our algorithm is more improved than performance of already developed combustible gas detectors. In the future, we'll research how to improve reliability from using count, temperature and humidity. And we'll design hardware applied explosion proof for safety.

Development of Intelligent Switchgear Monitoring System based on Smartphone (스마트폰 기반의 지능형 수배전반 모니터링 시스템 구현)

  • Jung, Hae-Kyung;Jeon, Gam-Pyo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.378-379
    • /
    • 2012
  • Nowadays, great energy consumption in advanced electrical industry has called up the great y efficiency. Electric power IT industry such as intelligent electric power system is receiving great attention and being marked up as a new growth engine. Through Intelligent electric power system, the electric power supply can be balance optimized according to demand, giving huge cost savings advantage for energy imports, infrastructure construction and operation. Nevertheless, the intelligent system promotes better reliability in power supply. Manual electric power management using man power appears to be non-practical. Real time electric power management on all facilities and equipment can be done through an intelligent electric power system, any accident break out issue can be easily recorded and recognized. In this paper, a fully integrated intelligent switchgear electric management system is developed to monitor and remote control the electrical switch based on smart phone. The proposed system is superior than the existing switchgear management system's weakness and can sharply improve effectiveness and stability with low cost. In future, the proposed system is expected to be greatly contributed to the advancement of the IT industry in electric power management.

  • PDF

Analysis of the Partial Discharge Pattern in XLPE Insulators using Distribution Statistical Models (분포통계모델에 의한 가교폴리에틸렌 절연체의 부분방전 패턴해석)

  • Kim Tag-Yong;Park Hee-Doo;Cho Kyung-Soon;Park Ha-Yong;Hong Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.947-952
    • /
    • 2006
  • It has been confirmed that the inner defect of insulator and the perfect diagnosis for aging are closely related to safe electric power transmission system and that the detection of accident and diagnosis technique turn out to be very important issues. But perfect diagnosis is difficult because discharge pattern is irregular. Thus, we investigated discharge pattern using the new distribution statistical models with cross-inked polyethylene(XLPE) specimens. Voltage was applied to power frequency by step method, and calibration of discharge was set to 50 pC. After the voltage was applied, it measured the discharge occurring during 10s. We investigated discharge pattern using the K-means analysis and Weibull function. We also investigated variation of centroid and shape parameter due to variation of voltage. As a result of analyzing K-means, it was confirmed that cluster including many object numbers was formed by the presence of void. And result of Weibull distribution, it was confirmed that shape parameter of discharge varied from 1.28 to 1.62 in no void specimens, and that shape parameter of discharge number varied from 1.28 to 1.62. In the void, shape parameter of discharge varied from 5.66 to 6.43, and shape parameter of discharge number varied from 5.05 to 5.08.

Development of the Electrodermal Activity Monitoring System for the Evaluation of Train Driver's Arousal State (기관사의 각성상태 평가를 위한 소형 피부전기활성도 측정 시스템 개발)

  • Lim, Min-Gyu;Lee, Young-Jae;Lee, Kang-Hwi;Kang, Seung-Jin;Kim, Kyeung-Nam;Park, Hee-Jung;Yang, Heui-Kyung;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1286-1293
    • /
    • 2014
  • Typically, studies through the simulation system have been progressed, because the evaluation of the driver's arousal state about the service of a actual train has risk of safety for the driver. When configured event same as the real in simulation system, the ability to cope with an accident situation may be the same each other. But the difference in the state of tension or arousal will occur. In this study, requested to cooperate with the railways in order to escape from these constraints, and the target of the experiment was to real engineer service. I was set about experiment when the train was stopped as safe as possible. As a result, the beta wave of EEG signals that representing complex calculations or anxiety is increased rapidly on the basis of a flag station from at the time of departure. The size of the electrodermal activity signal in response to movement of the body gave a noticeable. In terms of HRV, if the train approach a flag station gradually and the R-R interval is narrowed. So that the driver can be estimated as arousal state. In accordance with this study, if the quantitative standard of arousal state be based on the driver's biosignals will provide, it will be able to take advantage of development the system that would prevent train accidents caused by human error.

A Study Concerning Analysis of Arousal State of locomotive Engineering During Operating Train (열차 운행 중인 기관사의 각성상태 분석에 관한 연구)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Lee, Jae-Ho;Lim, Min-Gyu;Baek, Jong-Hyen;Song, Yong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.891-898
    • /
    • 2012
  • The study for the passenger's comfortableness of vehicles and the arousal of car drivers has been done widely. On the other hand, there are few studies for the locomotive engineers. Human error means that the mistakes made by human, recently it receives attention in the field of safety engineering and human engineering. Comparing the operating condition of train with car, because of the simplification of the visual stimulus, the arousal level on the train goes down easily. The arousal level down makes judgement down, the accident risk from human error is getting bigger. In this study, we measured bio-signals(ECG, EDA, PPG, respiration and EEG) from 6 locomotive engineers to evaluate their arousal state while they operated the train. Also we recorded the 3 axes acceleration signal showing the vibration state of train. Also, the existence of tunnels were simultaneously measured. At the station section where the train speed goes down, the size of vector's sum decreases because of reduced vibration. Beta component in EEG tends to increase at the entering point of each station and tunnel. It is due to the arousal reaction and tension growth. The mean SCR(skin conductance response) was more increased in neutral section. As the button control movement (body movement) increases in the neutral section, it is appeared that SCR increase. RR interval tends to gradually increase during train operation for 1 hour 40 minutes. However, It tends to sharply decrease at the stop station because strong concentration needed to stop train on the exact point. The engineer's arousal reaction can be checked through analysing the bio-signal change during train operation. Therefore, if this analysing result is adopted to the sleepiness prevention caution system, it will be useful for the safety train operation.