• Title/Summary/Keyword: Electrical Tree

Search Result 588, Processing Time 0.027 seconds

A Study on $\phi$-AE Distribution Patterns Characteristics due to Treeing Deterioration (트리잉 열화에 따른 $\phi$-AE 분포특성에 관한 연구)

  • 박재준;강태오;김재환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.1060-1070
    • /
    • 1992
  • In this paper, characteristics of Acoustic Emission in Low Density Polyethylene were studied from tree initiation to breakdown under long-term inhomogeneous alternative electrical field. The voltage levels used were 9, 11 and 14[kV]. Especially, a newly developed automatic measuring system was used to measure time variations of AE average amplitude, AE pulse number, AE pulse distribution patterns due to polarities. The patterns wer specially the variated patterns, when tree propagated. Also, parameters for dielectric breakdown prediction, which were suggested by Okamoto, were calculated. The result was analysed by tree shapes and partial discharge activities in tree due to tree initiation and propagation.

  • PDF

A Study on Growth Characteristics of Water Tree in XLPE (가교폴리에틸렌의 수트리 성장특성에 관한 연구)

  • 김덕근;임장섭;김철운;류경우;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.346-349
    • /
    • 1997
  • It is well known that water treeing is one of the main cause of breakdown in underground power cables, but water tree is not easy to observe. This aging phenomenon was resulted in effect of water and electric field and so on. In this paper, Distilled water was used as water electrode to observe the water treeing in XLPE(cross-linked polyethylene). To observe easily, sample was made of pallet types so water tree was able to show by microscope. As a result, electrical tree appears at niddle electrode tip which was concentrated electric field, but water tree was shown up different types that were appealed in total area of water electrode as well as water electrode tip.

  • PDF

The Tree Growth and Breakdown Characteristics of Unsaturated Polyester Dissolving the Electronegative Gases (부성기체를 용해시킨 불포화 폴리에스터의 Tree 성장과 절연파괴 특성)

  • 이보호;전춘생
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.178-184
    • /
    • 1992
  • This study treats the improvement of the dielectric strength of polymer by eliminating the air in it and dissolving electronegative gases. As experimental material, unsaturated polyester resin was used and the specimen was made by dissolving NS12T. SFS16T abd CCIS12TFS12T gases which have strong electron affinity. And also the electrical properties (tree growth and breakdown characteristics) of them were tested and discussed. The results are as follows. When the specimen dissolved with electronegative gas compared with one with air` 1) The tree breakdown voltage of the former is higher than that of the latter. 2) The tree growth of the former is slower than that of the latter. 3) The temperature dependence of the former is smaller than that of the latter. 4) The breakdown voltage of the specimen dissolved with electronegative gas is much higher than that dissolved with air.

An Analysis on Treeing in XLPE by means of Image Processing (화상처리에 의한 XLPE의 트리잉 해석)

  • 이재봉;임장섭;정우성;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.122-128
    • /
    • 1994
  • Studies on treeing phenomena have depended on the visual measurement using optical microscope. In the visual measurement, it is difficult to analyze the treeing in real time because voltages are applied discontinuously and impossible to calculate the deterioated area by treeing. Only tree type and length are studied. In this paper, image processing is introduced and voltages are applied continuously. The tree length and area are calculated in real time from tree inception to breakdown. Growing characteristics about tree types are compared for the normalized breakdown time.

Electrical Treeing Phenomena at the Interface of Conductor and Insulator (도전체와 절연체 계면에서의 전기트링 현상)

  • 조영신;심미자;김상욱
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.4
    • /
    • pp.236-242
    • /
    • 1995
  • This paper describes a study of electrical tree growth in DGEBA/MDA/SN system subjected to ac high electric field. The dielectric breakdown process, which consists of tree initiation, tree propagation and the complete puncture of the system was investigated. Dielectric breakdown always initiated from the needle tip where the electric field reinforcement is the highest. Higher temperature and voltage accelerated the tree growth and reduced the time to breakdown.

  • PDF

Assessment of Landscape Tree Vigor Using Cambial Electrical Resistance (형성층 전기저항을 이용한 조경용 수목 활력도 분석)

  • Hwang, Dong Kyu;Kim, Dong Yeob
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.302-306
    • /
    • 2016
  • There are various methods to evaluate tree vigor. Cambial electrical resistance represents tree vigor using the method of electrophysiological diagnosis. This study investigated the vigor of several tree species using Shigometer, and compared the differences among the species. The factors, such as foliation, trunk orientation and bark temperature, which affect electrical resistance were also investigated. The needle penetration into cambium was controlled to keep the depth consistent in order to minimize measurement error. Each of three trees were selected from Zelkova serrata, Ginkgo biloba, Metasequoia glyptostroboides, Pinus koraiensis, and Liriodendron tulipifera. The electrical resistances were measured at 60 and 120 cm height of the stem in 4 directions from March until May 2011. The soil conditions in surrounding areas and tree stress responses were also measured. The results were analyzed for the relationship between electrical resistance and the affecting factors. The electrical resistance showed a relatively higher level before foliation until mid-March. The values started to decline from April and recorded a minimal level on May 11. The changes of soil moisture, soil electric conductivity, and tree stress responses during the measurement period showed a similar trend to that of electrical resistance. The Pinus koraiensis, an evergreen conifer, showed few changes on the electrical resistance values during the measurement period. Zelkova serrata, Ginkgo biloba, and Metasequoia glyptostroboides showed the highest bark temperatures and lowest electrical resistances at their south-facing stem. Shigometer can provide measures simple to assess tree vigor in the fields, and to the management of trees.

Water Tree Characteristics of XLPE/EnBA Blends as a function of Crosslinking Coagent Contents (XLPE/EnBA에서의 가교조제에 따른 수트리 특성)

  • 오우정;서광석;김종은
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.219-222
    • /
    • 1998
  • In this study, The water tree characteristics were investigated when crosslinking coagent was added in XLPE/EnBA blends. When XLPE was blended with EnBA, there was a decrease of water tree length as an increase of nBA contents in XLPE/EnBA20 blends. The effect of crosslinking coagent. A was better than those of other crosslinking coagents B, C and D in water tree retardation. In case of XLPE/EnBA/Crosslinking coagent blends, water tree length was increased as the crosslinking coagents were increased from 0.2 to 2 phr in 2.0 phr DCP content. To clarify the effects of crosslinking coagent, the DCP contents were changed from 1.5 to 2.0 par in the same crosslinking coagent contents. Then, there was a decrease of water tree length as an increase of crosslinking coagent contents in 1.5 and 1.8 phr DCP contents.

  • PDF

Tree-Structure-Aware Genetic Operators in Genetic Programming

  • Seo, Kisung;Pang, Chulhyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.749-754
    • /
    • 2014
  • In this paper, we suggest tree-structure-aware GP (Genetic Programming) operators that heed tree distributions in structure space and their possible structural difficulties. The main idea of the proposed GP operators is to place the generated offspring of crossover and/or mutation in a specified region of tree structure space insofar as possible by biasing the tree structures of the altered subtrees, taking into account the observation that most solutions are found in that region. To demonstrate the effectiveness of the proposed approach, experiments on the binomial-3 regression, multiplexor and even parity problems are performed. The results show that the results using the proposed tree-structure-aware operators are superior to the results of standard GP for all three test problems in both success rate and number of evaluations.

A Study on Life Estimate of Insulation Cable for Image Processing of Electrical Tree (전기트리의 영상처리를 이용한 절연케이블의 수명예측에 관한 연구)

  • 정기봉;김형균;김창석;최창주;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.319-322
    • /
    • 2001
  • The proposed system was composed of pre-processor which was executing binary/high-pass filtering and post-processor which ranged from statistic data to prediction. In post-processor work, step one was filter process of image, step two was image recognition, and step three was destruction degree/time prediction. After these processing, we could predict image of the last destruction timestamp. This research was produced variation value according to growth of tree pattern. This result showed improved correction, when this research was applied image Processing. Pre-processing step of original image had good result binary work after high pass- filter execution. In the case of using partial discharge of the image, our research could predict the last destruction timestamp. By means of experimental data, this Prediction system was acquired ${\pm}$3.2% error range.

  • PDF

Performance Evaluation of a Buffered Fat-tree Network (Buffered Fat-tree Nework의 성능분석)

  • Cho, Sung-Lae;Shin, Tai-Z.;Yang, Myung-K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.775-777
    • /
    • 2000
  • 본 논문에서는 buffer를 장착한 양 방향성 $a{\times}b$ switch들로 구성된 fat-tree network의 성능 분석 기법을 제안하고, 분석 모형의 타당성을 검증하였다. 제안한 분석 기법은 먼저 스위치 내부의 데이터 이동 패턴을 확률식으로 표현하고. 나아가서 buffer를 장착한 $a{\times}b$ switch의 buffer 크기에 따른 정상상태 throughput을 간단한 수식으로 구할 수 있도록 하였다. 이를 토대로 buffer를 장착한 $a{\times}b$ switch로 구성된 fat-tree network의 성능을 분석하고, 제안한 분석모형의 실효성 입증을 위하여 simulation을 시행한 후 결과를 비교 분석하였다.

  • PDF