• Title/Summary/Keyword: Electrical Substation System

Search Result 504, Processing Time 0.034 seconds

Technology and Design Standards of 765kV 1cct Transmission Line (765kV 1회선 송전선로 기술기준 및 설계방안)

  • Sim, Soon-Bo;Min, Byeong-Wook;Park, K.H.;Jo, C.I.;Kim, J.Y.;Sin, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.80-82
    • /
    • 2002
  • To solve the difficulty in obtaining transmission routes and substation sites. increase the transmission capacity between generation sites and load centers. and enhance the stability of the power system. we have constructed and operated the 765kV double circuit transmission line(hereunder T/L) from the Dangjin thermal power plant and the Uljin nuclear power plant to the metropolitan. It makes it possible for us to accumulate know-how of the 765kV system that is the highest operating system level in Asia. As the second 765kV project, we are going to construct the 765kV single circuit T/L between Ansung and Gap yung. Because of the different electrical and mechanical characteristics. we are in need of different design technology. This paper presents the optimal design of 765kV single circuit transmission line after due consideration about the arrangement of conductors. the shape of a tower, insulation, etc.

  • PDF

Investigation of harmonic evaluating factor in electric railroad (전기철도에서의 고조파 평가지수 검토)

  • Lee, Chang-Mu;Han, Moon-Seub;Ahn, Young-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1251-1253
    • /
    • 2002
  • Most of the substations, which had been constructed so far, only took into account the current distortion as an evaluation factor for harmonics. There is, however, growing tendency for the currently constructed substations to construct transmission lines in an underground way. Therefore, the overhaul investigation on the psophometric current is all the more necessary. In this study, the harmonic current, the current distortion and the psophometric current, which flow into the substation in accordance with a feeding system and the number of trains in operation are investigated and compared based on the six-port analysis method of feeding system, which has been proposed.

  • PDF

GISPD Measurement Using UHFPD Measurement System (UHFPD측정시스템을 이용한 GISPD측정)

  • Choi, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1857-1859
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the noise suppression methods and the PD measurement results of the in-service substation by the developed UHF PD measurement system which consists of the external UHF coupler, the UWB LNA and the digital storage oscilloscope. As results, it was found that the effect of the noise suppression methods were verified and that the developed external UHF coupler showed a better detection sensitivity than a conventional external coupler.

  • PDF

Establish the remote portrait supervisory system of distribution line using OPNW (OPNW를 이용한 배전선로 원격화상 감시시스템 구축)

  • Oh, Myon-Taek;Lee, Seung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.103-106
    • /
    • 2008
  • OPNW, which takes charge of the outer neutral wire role and the inner optical network role, was developed at the first time among nation and substituted the neutral wire of distribution line between electric power substation and neighboring station. This paper refers to results about its optical character measured periodically, and examines closely whether the unique matter will be occurred or not about the role of neutral wire during more than one year. Also, established OPNW became a new chance to distribution facility's working by establishing remote portrait supervisory system and doing remote supervisory about essential equipment of distribution line.

  • PDF

A study on dynamic simulation for estimation of leakage current (누설전류 예측을 위한 동적 시뮬레이션에 관한 연구)

  • Jung, Ho-Sung;Han, Moon-Seob;Park, Young;Chung, Sang-Gi;Kwon, Sam-Young;Lee, Jea-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.250-252
    • /
    • 2008
  • DC traction system generates leakage current because running rails are used in return circuit. And it is very important to estimate the leakage current to the train operation situation. Therefore this paper presents dynamic simulation technique that is very similar to the real operation situation using TPS and PSCAD/EMTDC. For this we model DC traction system included in DC substation, variable feeding circuit model and variable train model. And we extract train location and power using TPS program and use these data for dynamic simulation. Finally we can estimate leakage current to the various operation condition using dynamic simulation.

  • PDF

Coordination control method between FACTS and Reactive power sources for local voltage control (지역전압 안정화를 위한 FACTS와 조상설비간의 협조제어기법)

  • Lee, Geun-Joon;Lee, Hyun-Chul;Yoon, Jong-Su;Jang, B.H.;Jung, S.W.;Bak, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.181-183
    • /
    • 2008
  • This paper suggests local voltage control method to achieve coordinative control between STATCOM and other reactive power resources, such as Shunt Capacitor/Reactors and OLTC. Voltage/Reactive power control has various difficult aspects to control because of analysis and system dynamics error. This control method suggests practical algorithm regarding system voltage and reactive power status which is easy to implement in substation basis. In normal status, STATCOM-Shunts-OOTC are in operation. In emergency status, OLTC is locked. This algorithm is tested and verified in EMTDC.

  • PDF

Performance Test of the IED control function based on IEC 61850 (IED IEC 61850 제어기능에 대한 성능시험)

  • Lee, N.H.;Jang, B.T.;Lee, M.S.;Han, J.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.115_116
    • /
    • 2009
  • IEC 61850 based substation automation system mainly consists of a various of protective and control IEDs. In order to implement the system, All of them should require the performance verification of IEC 61850 communication services for the assurance of interoperability throughout the digital network. This paper shows a research result on the testing method of IEC 61850 control communication interface of IEDs according to IED IEC 61850 conformance test procedures.

  • PDF

A Using Study for Fault Locator Algorithm of Distribution System (배전계통 고장점 표정 알고리즘 적용 연구)

  • Lee, Sung-Woo;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.74_76
    • /
    • 2009
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.

  • PDF

A Restoration Algorithm using Moving the tie Switch in Distribution System in case of Fault Occur in Power system Substation MTR (변전소 내 주변압기 사고 발생 시 배전계통 연계점 이동을 통한 복구 알고리즘)

  • Hong, Jun-Ho;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Il-Hyung;Kim, Tae-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.159_160
    • /
    • 2009
  • In this paper proposes a new algorithm of efficiency outage restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads.

  • PDF

A study on Application of UVLS model to decrease the load shadding in Seoul Area (저전압부하차단시스템(UVLS) 모델을 이용한 수도권 부하차단용량 산정에 관한 연구)

  • Kang, Dae-Eon;Lee, Back-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.184-186
    • /
    • 2005
  • Increasement of power demand rapid industrial growth has led the expansion of power system, and it caused construction of large power transmission line(like 765kV T/L) and substation. If there are T/L faults (route contingency etc), it lead to the large scale black out in SEOUL AREA (the center of load). To minimize damage which caused by the large scale black out, KEPCO selects the method of load shadding. In this work, instead of general method of load shadding, We study the application of UVLS model to decrease the load shadding in SEOUL AREA. The study result of using the UVLS model showed that the amont of load shadding can be decreased about 400 MW compare to the existing load shadding system.

  • PDF