• Title/Summary/Keyword: Electrical Substation System

Search Result 504, Processing Time 0.023 seconds

A Study on Analysis Method of DC Electric Railroad using Terminal Network Analysis (단자망을 이용한 직류전기철도 해석방안에 관한 연구)

  • Lee, Chang-Mu;Jang, Dong-Uk;Kim, Jae-Won;Han, Mun-Seup;Jung, Hwan-Su;Kim, Joo-Rak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1913-1918
    • /
    • 2016
  • In order to analyze the power consumption pattern of the DC urban rail system, the method to obtain a solution establishing the current equation according to fixed position of the substation and varying position of the train is used. The proposed analysis method using the network analysis is to model the transfer function of the component constituting a direct current power supply system (dc substation, train, catenary) to the voltage and current. By multiplying the model formula consecutive, it can calculate the voltage and current of each element of power supply circuit and shows a simple case analysis.

Development of Optimal Substation Expansion Planning Method using ANP (ANP에 의한 최적 변전소 신.증설계획법의 개발)

  • Kim, Yong-ha;Lee, Buhm;Choi, Sang-kyu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.8
    • /
    • pp.385-390
    • /
    • 2002
  • This paper presents a substation expansion planning method with quantitative analysis using ANP. To calculate the reliability factor and economy factor of the system, reliability indices and total construction cost is used. With these factors, new ANP model which select the best plan either economy or reliability among various alternatives is developed. This model can assist the decision making for the system planner. The usefulness of the method is verified by applying it to the large-scaled distribution system.

UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower (UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계)

  • Lee, Dong-Cheol;Bae, Ul-Lok;Kim, Woo-Jung;Min, Bung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

A Study on the Real Time Measuring Technique of Stray Current by Using Return Current Ratio in the DC Railway System (직류급전시스템에서의 귀환전류 변화비를 이용한 표유전류 실시간 감시기법에 관한 연구)

  • Jung, Ho-Sung;Park, Young;Kim, Hyeng-Chul;Min, Myung-Hwan;Shin, Myong-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.892-898
    • /
    • 2011
  • In DC electric railways, while an electric rail car is driving, a part of the working current returned to the substation through rails leaks into the ground. Such a stray current causes railway facilities and metal objects to corrode electrolytically. Therefore, change of stray current needs to be monitored constantly. But so far in domestic, the research on stray current measuring techniques and system adaption are insufficient. To estimate stray current, this paper addresses a method of monitoring the return current that is returned into the negative pole of the substation in real time.

Modeling of Battery Energy Storage System at Substation for Load Leveling and Its Economic Evaluation (부하 평준화를 위한 변전소 설치 배터리 에너지 저장장치의 모델 및 경제성 평가에 관한 연구)

  • Cho, Sung-Min;Shin, Hee-Sang;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.950-956
    • /
    • 2012
  • As development of battery technologies, the installation of Battery Energy Storage System (BESS) increased. The BESS can be used for various purposes such like frequency response, load leveling, and fluctuation mitigation of renewable energy generators. In this paper, three state BESS model is proposed. the BESS model considering charge, discharge and keeping efficiency, and life cycle according to depth of discharge (DOD). Then, the benefit and cost of BESS installed at substation for load leveling are summarized. The economic evaluation of BESS is analyzed using net present values (NPV) analysis. In case study, the NPV analysis of NaS battery system is carried out using the proposed BESS model. Because the result of economic evaluation of BESS using nowadays cost data is not positive, the sensitivity analysis of BESS is conducted by changing the capital cost and energy cost.

A Study on the Restoration System for Distribution Network (배전계통의 정전복구 시스템에 관한 연구)

  • Lee, Heung-Jae;Lee, Chul-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.761-763
    • /
    • 1997
  • As the power system network is enlarged and complicated gradually, the automation of power system network is essential to enhance the reliability and performance of the operation of power system. Distribution restoration is a major part of the automation. This paper proposes a new distribution restoration system to restore healthy blackout regions by the hierarchical cooperation with the substation automation systems. In proposed system, the range of restoration is extended to substations and the performance as well as the switching efficiency of restoration system is enhanced.

  • PDF

Performance Analysis of the GOOSE Transmission of an IED Considering Network Redundancy (네트워크 이중화를 고려한 IED GOOSE 전송에 관한 성능 분석)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.75-80
    • /
    • 2009
  • In order to prevent loss of communication packets and drop of transmission speed owing to the network fault occurrence, it should be considered network redundancy. That is why a messages of IED GOOSE is the critical signal in charge of protection and control of the substation. So most of users implement the substation automation system with Hybrid network topology ant IED supporting double ethernet ports. Because IEC 61850 GOOSE conformance test is limited in the functional test, this paper suggests how to test the performance of IED GOOSE transmission considering Network redundancy, and describes the analysis of an example test on real IEDs and how to impact the IED GOOSE performance to the substation automation system.

Improvement Method of SVR Control in Power Distribution System Interconnected Distributed Generator (분산전원이 연계된 배전계통에 있어서 선로전압조정장치(SVR)의 전압제어 개선방안)

  • Lee, Hyun-Ok;Huh, Jae-Sun;Kim, Byung-Ki;Rho, Dae-Seok;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.224-229
    • /
    • 2014
  • This paper presents the novel voltage control method in power distribution system with distributed generators. The voltage in distribution systems is regulated by Under Load Tap Changer(ULTC) of substation and pole transformer of primary feeders. Recently, Step Voltage Regulator(SVR) is getting located at distribution feeders to regulate effectively voltage of primary feeders. But the effectiveness of SVR decreases due to independent operation between SVR and ULTC, and also the existing Line Drop Compensator(LDC) method considering the distributed generators may be not able to regulate the proper voltage in a permissible range. Thus, this paper presents a optimal voltage control algorithm of SVR by using the secondary voltage data of main transformer in substation.

A Study on the Criteria of Earthing Systems for Substation (변전소의 접지설계기준에 관한 연구)

  • Kim, I.S.;Kim, M.K.;Huh, D.H.;Yoon, J.Y.;Han, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.152-154
    • /
    • 2007
  • This paper represents the criteria of earthing system for substation design in Korea. The construction of new substations and expansion of existing facilities are commonplace projects in KEPCO(Korea Electric Power Corporation). The KEPCO has had the only design criteria, which need to be adequate criteria considering the new technology and environment in Korea.

  • PDF

A study of bad data processing application in the substation (변전소내 Bad Data Processing어 관한 연구)

  • Jin B.G.;Choi I.S.;Hyun S.H.;Lee S.J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.406-408
    • /
    • 2004
  • It is very necessary to adopt bad data processing in order to maintain the security and the reliability of data acquisition and management in the substation. This paper presents a bad data processing method of per module unit by using rule based system. The propriety of this method has been verified by the case study

  • PDF