• Title/Summary/Keyword: Electrical Safety Monitoring System

Search Result 140, Processing Time 0.029 seconds

A Study on Safety System for Blasting Workers using Real Time Location System in the Shipyard (선박용 블라스팅 셀 내에서의 실시간 위치 추적 기술을 이용한 작업자 안전 시스템에 대한 연구)

  • Yun, Won-Jun;Ro, Young-Shic;Cho, Sang-Bock
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.6
    • /
    • pp.836-842
    • /
    • 2010
  • Safety system including location monitoring system for blasting workers was studied. Positioning performance of the location monitoring system was highly dependent on communication protocol and the number of access points in the blasting cell. RTLS(Real Time Location System) is an important technology to develop the location information of workers and variously used to enhance workers safety. Location monitoring system with Cell-ID and RSSI wireless communication technology was verified to have a proper positioning performance for the steel block application.

An analysis of the state of operation of the electrical safety emergency dispatch system (전기안전 긴급출동제도 운영 실태 분석)

  • Yoo, Jae-Geun;Kim, Jae-Hyun;Lee, Ki-Sik;Koo, Kyung-Wan;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1748-1751
    • /
    • 2012
  • This paper describes the background of the electrical safety emergency dispatch system and analyzes the operational status of the system. This system is to provide the enhanced electrical safety service to general-purpose electrical equipment users. Annual average of about 6 million cases have been implemented since 2005. In order to enhance electrical safety service and more effectively prevent electrical disasters in future, institutional expansion of the electrical safety emergency dispatch system with keeping budget is necessary. If periodic inspections with a remote monitoring system is applied, the effect of electrical safety will be improved.

Wireless Sensor Network for Health & Safety Monitoring of Small Sized Structures (소규모 구조물의 안전진단을 위한 무선 센서 네트워크)

  • Maeng, Ju-Sang;Kim, Il-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1099-1105
    • /
    • 2018
  • Wireless sensor networks have been shown to be an effective method for health monitoring of civil structures. In this paper a wireless strain sensor system which will allow easier collection of accurate strain signals in small sized structures is described. The experiment result shows that the developed wireless sensor system and the proposed network system are fit for health & safety monitoring and control of structures.

An Improved Interval AHP Method for Assessment of Cloud Platform-based Electrical Safety Monitoring System

  • Wang, Shou-Xiang;Ge, Lei-Jiao;Cai, Sheng-Xia;Zhang, Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.959-968
    • /
    • 2017
  • Electrical safety monitoring System (ESMS) is a critical component in modern power systems, which is characterized by large-scale access points, massive users and versatile requirements. For convenience of the information integration and analysis, the software development, maintenance, and application in the system, the cloud platform based ESMS is established and assessed in this paper. Firstly the framework of the system is proposed, and then the assessment scheme with a set of evaluation indices are presented, by which the appropriate cloud product can be chosen to meet the requirements of a specific application. Moreover, to calculate the weights of the evaluation indices under uncertainty, an improved interval AHP method is adopted to take into consideration of the fuzziness of expert scoring, the qualitative consistency test, and the two normalizations in the process of eigenvectors. Case studies have been made to verify the feasibility of the assessment approach for ESMS.

Local Installation Device Models for Remote Electrical Safety Monitoring of Electrical Facilities for General Use (일반용 전기설비의 원격 전기안전 감시를 위한 수용가 설치 장치 모델)

  • Jeon, Hyun-Jae;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.101-107
    • /
    • 2007
  • In order to introduce remote monitoring system for effective safety management of electrical facilities for general use, which the most of electrical fires and non-inspection problems due to absence are generated development of local device model considering cost and installation is requested. This paper presents local device models for remote electrical safety inspection of electrical facilities for general use and in order to rational model according to installation place of electrical facilities for general use, compare and analysis cost, installation and communication method of local device models. The results show that rational model for remote safety inspection of electrical facilities located in houses, which occupy the must of electrical facilities for general use, is to give safety monitoring ability to low voltage remote meter reading(or automatic meter reading: AMR).

The Survey of Domestic and Foreign for On-Line Monitoring System at Low Voltage Facilities (저전압 전기설비의 온라인 감시시스템 구축을 위한 국내외 실태조사)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.75-81
    • /
    • 2007
  • In this paper, the survey and the analysis of domestic and foreign for on-line monitoring system at low voltage facilities example for value added service about electrical safety were executed. According to survey, in Japan, they are executing the on-line electrical facilities monitoring in based on IT basic law for the information of society construction and not only electrical safety but also value added service such as alarm for earthquake, security are being done. In USA and Europe using power line communication(PLC), the on-line observation and building district management service were being realized. Observing the domestic case, electrical safety related with service such as distribution panel product incorporating load management and leakage current measurement was being executed in some companies. From the survey, it is necessary to improve on the law and the system for market activity in domestic.

Analysis of Remote Electrical Facilities Safety Checkup for General Use (일반용 전기설비 수용가의 원격전기안전점검 모델 설계 및 요소기술 분석)

  • Yoo, Jae-Geun;Choi, Myeong-Il;Jeon, Jeong-Chay
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2214-2215
    • /
    • 2008
  • KESCO performed periodical inspection every 1${\sim}$3 years to check the status of maintenance and performance of electric installations for general use (less than 600V in voltage and 75kW in capacity in residential homes) but recently a resident have been avoiding periodical check due to increase of sex crime and empty house, which more and more difficult to secure electrical safety of installation. In order to solve non-inspection problems and improve efficiency of inspection, this paper introduce the model of remote monitoring system that check electrical facilites for general use and we are developing remote monitoring device for reliability test.

  • PDF

A Study on the Applying of Balancing Control and Safety Monitoring Technology of Cargo on the Freight Train (화물열차 적재화물의 균형제어 및 안전모니터링기술 적용 연구)

  • Han, Seong-Ho;Han, Young-Jae;Lee, Suk;Kim, Young-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.224-228
    • /
    • 2017
  • Recently, in order to improve the efficiency of freight transportation on existing lines, a new freight train model is needed to develop urgently. The weight balance of the cargo for the freight vehicle is very important for the stability of the running train and the safe transportation of the cargo. For achieving the cargo weight balance, we proposed a Cargo Balancing Control(CBC) system on the Freight vehicle equipped in between under frame of car body and bogie system. The Cargo Safety Monitoring(CSM) system was designed to supervise status of the Cargo on freight train. The monitoring system can display real time status data from sensors and various signals effectively. We suggested that this paper is a very useful approach for keeping the safety of running freight trains on existing lines.

Establishment of Cyber Security Countermeasures amenable to the Structure of Power Monitoring & Control Systems (전력계통 제어시스템 구조에 따른 사이버 보안대책 수립)

  • Woo, Pil Sung;Kim, Balho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1577-1586
    • /
    • 2018
  • The emergence of the Smart Grid is an integrated solution for the next generation power system that combines IT technology in the power system to create optimal energy utilization and various services. However, these convergence technologies (power systems and information communications) are not only improving the related technologies but also producing various problems especially exposure to cyber risk. In particular, the intelligent power grid has security vulnerabilities through real-time information sharing among various organically linked systems, and it is more complicated than the cyber risk problem in the existing IT field and is directly connected to national disaster accidents. Therefore, in order to construct and operate a more stable smart grid, this paper analyzes the system of power system control system in Korea, and proposes a cyber security element definition and a countermeasure establishment method of power monitoring & control systems based on security standards of smart grid (No. SPS-SGSF-121-1-1).

The Development of Low Cost Power Components Measurement and Record System for Monitoring Electrical Equipment Operation Status (전력설비 동작 상태 감시를 위한 저가형 전력 성분 측정 및 기록 시스템의 개발)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4855-4862
    • /
    • 2015
  • This paper proposes low price power component measurement and record system for preventing electrical safety accident and supporting accident cause analysis by periodically monitoring and recording the operation status of electrical equipments. The proposed system was designed by mainly using parts to measure accurate power component but reduce cost. Especially, low cost and high effectiveness system implementation was possible by using MAXIM 78M6631 to calculate power components in the definition of IEEE Standard 1459-2010 related power quality. The measurement performance of the developed system is tested by using standard devices such as YOKOGAWA power analyzer WT1600. The test results showed that accuracy of the developed system is less than 0.5 % and the developed system is tested in a real area to verify the operation reliability and remote monitoring performance of the system over 6 months.